Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -244,7 +244,7 @@ 244 244 User need to configure SDI-12-LB to communicate with SDI-12 sensors otherwise the uplink payload will only include a few bytes. 245 245 246 246 247 -=== 2.3.1 Basic SDI-12 debug command ===247 +=== 2.3.1 Basic SDI-12 debug command === 248 248 249 249 250 250 User can run some basic SDI-12 command to debug the connection to the SDI-12 sensor. These commands can be sent via AT Command or LoRaWAN downlink command. ... ... @@ -275,7 +275,6 @@ 275 275 The following is the display information on the serial port and the server. 276 276 277 277 278 - 279 279 [[image:image-20230201091257-8.png]] 280 280 281 281 ... ... @@ -282,50 +282,54 @@ 282 282 [[image:image-20230201091257-9.png||height="225" width="1242"]] 283 283 284 284 285 -aM!,aMC!, aM1!- aM9!, aMC1!- aMC9! 284 +==== **aM!,aMC!, aM1!- aM9!, aMC1!- aMC9!** ==== 286 286 287 -aM!: Start Non-Concurrent Measurement 288 288 289 -aM C!: Start Non-Concurrent Measurement– Request CRC287 +**aM! **: Start Non-Concurrent Measurement 290 290 291 -aM 1!-aM9!:AdditionalMeasurements289 +**aMC! **: Start Non-Concurrent Measurement – Request CRC 292 292 293 -aM C1!- aMC9!: Additional Measurements– Request CRC291 +**aM1!- aM9! **: Additional Measurements 294 294 293 +**aMC1!- aMC9!** : Additional Measurements – Request CRC 295 295 295 + 296 296 * AT Command : AT+ADDRM=0,1,0,1 297 297 * LoRaWAN Downlink(prefix 0xAA01): 0xAA 01 30 01 00 01 298 298 299 299 Downlink:AA 01 aa bb cc dd 300 300 301 -aa: SDI-12 sensor address. 301 +**aa**: SDI-12 sensor address. 302 302 303 -bb: 0: no CRC, 1: request CRC 303 +**bb**: 0: no CRC, 1: request CRC 304 304 305 -cc: 1-9: Additional Measurement, 0: no additional measurement 305 +**cc**: 1-9: Additional Measurement, 0: no additional measurement 306 306 307 -dd: delay (in second) to send **aD0!** to get return. 307 +**dd**: delay (in second) to send **aD0!** to get return. 308 308 309 309 310 310 The following is the display information on the serial port and the server. 311 311 312 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.png]] 313 313 314 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image020.png]]313 +[[image:image-20230201091630-10.png]] 315 315 316 316 316 +[[image:image-20230201091630-11.png||height="247" width="1165"]] 317 317 318 -aC!, aCC!, aC1!- aC9!, aCC1!- aCC9! 319 319 320 -aC!: Start Concurrent Measurement 321 321 322 -aCC! :StartConcurrentMeasurement– RequestCRC320 +==== **aC!, aCC!, aC1!- aC9!, aCC1!- aCC9! ** ==== 323 323 324 -aC1!- aC9!: Start Additional Concurrent Measurements 325 325 326 -aC C1!-aCC9!: StartAdditionalConcurrent Measurements – Request CRC323 +**aC!** : Start Concurrent Measurement 327 327 325 +**aCC!** : Start Concurrent Measurement – Request CRC 328 328 327 +**aC1!- aC9!** : Start Additional Concurrent Measurements 328 + 329 +**aCC1!- aCC9!** : Start Additional Concurrent Measurements – Request CRC 330 + 331 + 329 329 * AT Command : AT+ADDRC=0,1,0,1 330 330 331 331 * LoRaWAN Downlink(0xAA02): 0xAA 02 30 01 00 01 ... ... @@ -332,24 +332,29 @@ 332 332 333 333 Downlink: AA 02 aa bb cc dd 334 334 335 -aa: SDI-12 sensor address. 338 +**aa**: SDI-12 sensor address. 336 336 337 -bb: 0: no CRC, 1: request CRC 340 +**bb**: 0: no CRC, 1: request CRC 338 338 339 -cc: 1-9: Additional Measurement, 0: no additional measurement 342 +**cc**: 1-9: Additional Measurement, 0: no additional measurement 340 340 341 -dd: delay (in second) to send **aD0!** to get return. 344 +**dd**: delay (in second) to send **aD0!** to get return. 342 342 343 343 344 344 The following is the display information on the serial port and the server. 345 345 346 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]] 347 347 348 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]350 +[[image:image-20230201091954-12.png]] 349 349 350 350 351 -a R0!-aR9!, aRC0!-aRC9!353 +[[image:image-20230201091954-13.png||height="203" width="1117"]] 352 352 355 + 356 +(% style="display:none" %) (%%) 357 + 358 +==== **aR0!- aR9!, aRC0!- aRC9!** ==== 359 + 360 + 353 353 Start Continuous Measurement 354 354 355 355 Start Continuous Measurement – Request CRC ... ... @@ -360,46 +360,48 @@ 360 360 361 361 Downlink: AA 03 aa bb cc dd 362 362 363 -aa: SDI-12 sensor address. 371 +**aa**: SDI-12 sensor address. 364 364 365 -bb: 0: no CRC, 1: request CRC 373 +**bb**: 0: no CRC, 1: request CRC 366 366 367 -cc: 1-9: Additional Measurement, 0: no additional measurement 375 +**cc**: 1-9: Additional Measurement, 0: no additional measurement 368 368 369 -dd: delay (in second) to send **aD0!** to get return. 377 +**dd**: delay (in second) to send **aD0!** to get return. 370 370 371 371 372 372 The following is the display information on the serial port and the server. 373 373 374 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]] 375 375 376 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]] 377 377 378 -1. 379 -11. 380 -111. Advance SDI-12 Debug command 384 +[[image:image-20230201092208-14.png]] 381 381 386 + 387 +[[image:image-20230201092208-15.png||height="214" width="1140"]] 388 + 389 + 390 +=== 2.3.2 Advance SDI-12 Debug command === 391 + 392 + 382 382 This command can be used to debug all SDI-12 command. 383 383 384 384 385 385 LoRaWAN Downlink: A8 aa xx xx xx xx bb cc 386 386 387 - (aa: total SDI-12 command length)398 +**aa **: total SDI-12 command length 388 388 389 - (xx: SDI-12 command)400 +**xx **: SDI-12 command 390 390 391 - (bb: Delay to wait for return)402 +**bb **: Delay to wait for return 392 392 393 - (cc: 0: don’t uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100)404 +**cc **: 0: don't uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100 394 394 395 395 396 -Example: AT+CFGDEV =0RC0!,1 407 +**Example: **AT+CFGDEV =0RC0!,1 397 397 398 -0RC0!: SDI-12 Command, 409 +**0RC0! **: SDI-12 Command, 399 399 400 -1: Delay 1 second. ( 0: 810 mini-second) 411 +**1 **: Delay 1 second. ( 0: 810 mini-second) 401 401 402 - 403 403 Equal Downlink: 0xA8 05 30 52 43 30 21 01 01 404 404 405 405 ... ... @@ -406,10 +406,11 @@ 406 406 The following is the display information on the serial port and the server. 407 407 408 408 409 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]419 +[[image:image-20230201092355-16.png]] 410 410 411 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]] 412 412 422 +[[image:image-20230201092355-17.png||height="426" width="1135"]] 423 + 413 413 1. 414 414 11. 415 415 111. Convert ASCII to String