From version < 2.1 >
edited by Xiaoling
on 2023/01/31 18:35
To version < 2.2 >
edited by Xiaoling
on 2023/01/31 18:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,0 +1,1409 @@
1 +(% style="text-align:center" %)
2 +[[image:image-20230131183542-1.jpeg||height="694" width="694"]]
3 +
4 +**Table of Contents:**
5 +
6 +
7 +
8 +
9 +
10 +
11 +
12 +
13 +
14 +
15 +
16 +
17 +
18 +
19 +1. Introduction
20 +11. ​What is LoRaWAN Pressure Sensor
21 +
22 +The Dragino **SDI-12-LB** is a **SDI-12 to LoRaWAN Convert **designed for Smart Agriculture solution.
23 +
24 +
25 +SDI-12 (Serial Digital Interface at 1200 baud) is an asynchronous [[serial communications>>url:https://en.wikipedia.org/wiki/Serial_communication]] protocol for intelligent sensors that monitor environment data. SDI-12 protocol is widely used in Agriculture sensor and Weather Station sensors.
26 +
27 +
28 +**SDI-12-LB** has SDI-12 interface and support 12v output to power external SDI-12 sensor. It can get the environment data from SDI-12 sensor and sends out the data via LoRaWAN wireless protocol.
29 +
30 +
31 +The LoRa wireless technology used in **SDI-12-LB** allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
32 +
33 +
34 +**SDI-12-LB** is powered by **8500mAh Li-SOCI2 battery**, it is designed for long term use up to 5 years.
35 +
36 +
37 +Each **SDI-12-LB** is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
38 +
39 +
40 +
41 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
42 +
43 +
44 +
45 +
46 +
47 +*
48 +*1. ​ Features
49 +* LoRaWAN 1.0.3 Class A
50 +* Ultra-low power consumption
51 +* Controllable 5v and 12v output to power external sensor
52 +* SDI-12 Protocol to connect to SDI-12 Sensor
53 +* Monitor Battery Level
54 +* Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
55 +* Support Bluetooth v5.1 and LoRaWAN remote configure.
56 +* Support wireless OTA update firmware
57 +* Uplink on periodically
58 +* Downlink to change configure
59 +* 8500mAh Battery for long term use
60 +
61 +
62 +1.
63 +11. Specification
64 +
65 +**Micro Controller:**
66 +
67 +* MCU: 48Mhz ARM
68 +* Flash: 256KB
69 +* RAM: 64KB
70 +
71 +**Common DC Characteristics:**
72 +
73 +* Supply Voltage: 2.5v ~~ 3.6v
74 +* Operating Temperature: -40 ~~ 85°C
75 +
76 +**LoRa Spec:**
77 +
78 +* Frequency Range,  Band 1 (HF): 862 ~~ 1020 Mhz
79 +* Max +22 dBm constant RF output vs.
80 +* RX sensitivity: down to -139 dBm.
81 +* Excellent blocking immunity
82 +
83 +
84 +**Current Input Measuring :**
85 +
86 +* Range: 0 ~~ 20mA
87 +* Accuracy: 0.02mA
88 +* Resolution: 0.001mA
89 +
90 +
91 +**Voltage Input Measuring:**
92 +
93 +* Range: 0 ~~ 30v
94 +* Accuracy: 0.02v
95 +* Resolution: 0.001v
96 +
97 +
98 +**Battery:**
99 +
100 +* Li/SOCI2 un-chargeable battery
101 +* Capacity: 8500mAh
102 +* Self-Discharge: <1% / Year @ 25°C
103 +* Max continuously current: 130mA
104 +* Max boost current: 2A, 1 second
105 +
106 +
107 +**Power Consumption**
108 +
109 +* Sleep Mode: 5uA @ 3.3v
110 +* LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
111 +
112 +
113 +1.
114 +11. Connect to SDI-12 Sensor
115 +
116 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image002.png]]
117 +
118 +
119 +
120 +1.
121 +11. Sleep mode and working mode
122 +
123 +
124 +**Deep Sleep Mode: Sensor doesn’t have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.**
125 +
126 +
127 +**Working Mode: In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.**
128 +
129 +
130 +
131 +
132 +
133 +1.
134 +11. Button & LEDs
135 +
136 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image003.png]]
137 +
138 +
139 +
140 +|**Behavior on ACT**|**Function**|**Action**
141 +|Pressing ACT between 1s < time < 3s|Send an uplink|(((
142 +If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, **blue led** will blink once.
143 +
144 +Meanwhile, BLE module will be active and user can connect via BLE to configure device.
145 +)))
146 +|Pressing ACT for more than 3s|Active Device|(((
147 +**Green led** will fast blink 5 times, device will enter **OTA mode** for 3 seconds. And then start to JOIN LoRaWAN network.
148 +
149 +**Green led** will solidly turn on for 5 seconds after joined in network.
150 +
151 +Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network.
152 +)))
153 +|Fast press ACT 5 times.|Deactivate Device|red led will solid on for 5 seconds. Means SDI-12-LB are in Deep Sleep Mode.
154 +
155 +
156 +
157 +1.
158 +11. Pin Mapping
159 +
160 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image004.png]]
161 +
162 +1.
163 +11. BLE connection
164 +
165 +SDI-12-LB support BLE remote configure.
166 +
167 +
168 +BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
169 +
170 +* Press button to send an uplink
171 +* Press button to active device.
172 +* Device Power on or reset.
173 +
174 +If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
175 +
176 +
177 +
178 +
179 +1.
180 +11. Mechanical
181 +
182 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image005.png]]
183 +
184 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image006.png]]
185 +
186 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image007.png]]
187 +
188 +
189 +
190 +
191 +1. Configure SDI-12 to connect to LoRaWAN network
192 +11. How it works
193 +
194 +The SDI-12-LB is configured as **LoRaWAN OTAA Class A** mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the SDI-12-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
195 +
196 +
197 +1.
198 +11. ​Quick guide to connect to LoRaWAN server (OTAA)
199 +
200 +Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example.
201 +
202 +
203 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image008.png]]
204 +
205 +
206 +The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
207 +
208 +
209 +**Step 1**: Create a device in TTN with the OTAA keys from SDI-12-LB.
210 +
211 +Each SDI-12-LB is shipped with a sticker with the default device EUI as below:
212 +
213 +
214 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image009.png]]
215 +
216 +
217 +
218 +
219 +
220 +You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
221 +
222 +
223 +**Register the device**
224 +
225 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image010.png]]
226 +
227 +
228 +**Add APP EUI and DEV EUI**
229 +
230 +
231 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image011.png]]
232 +
233 +
234 +**Add APP EUI in the application**
235 +
236 +
237 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image012.png]]
238 +
239 +
240 +**Add APP KEY**
241 +
242 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image013.png]]
243 +
244 +
245 +**Step 2**: Activate on SDI-12-LB
246 +
247 +
248 +Press the button for 5 seconds to activate the SDI-12-LB.
249 +
250 +
251 +**Green led** will fast blink 5 times, device will enter **OTA mode** for 3 seconds. And then start to JOIN LoRaWAN network. **Green led** will solidly turn on for 5 seconds after joined in network.
252 +
253 +
254 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image014.png]]
255 +
256 +
257 +
258 +
259 +
260 +1.
261 +11. ​SDI-12 Related Commands
262 +
263 +
264 +User need to configure SDI-12-LB to communicate with SDI-12 sensors otherwise the uplink payload will only include a few bytes.
265 +
266 +
267 +1.
268 +11.
269 +111. Basic SDI-12 debug command
270 +
271 +User can run some basic SDI-12 command to debug the connection to the SDI-12 sensor. These commands can be sent via AT Command or LoRaWAN downlink command.
272 +
273 +
274 +If SDI-12 sensor return value after get these commands, //SDI-12-LB// will uplink the return on FPORT=100, otherwise, if there is no response from SDI-12 sensor. //SDI-12-LB// will uplink NULL (0x 4E 55 4C 4C) to server.
275 +
276 +
277 +The following is the display information on the serial port and the server.
278 +
279 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image015.png]]
280 +
281 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image016.png]]
282 +
283 +al!  ~-~- Get SDI-12 sensor Identification
284 +
285 +* AT Command: AT+ADDRI=aa
286 +* LoRaWAN Downlink(prefix 0xAA00): AA 00 aa
287 +
288 +Parameter: aa: ASCII value of SDI-12 sensor address in downlink or HEX value in AT Command)
289 +
290 +Example : AT+ADDRI=0 ( Equal to downlink: 0x AA 00 30)
291 +
292 +
293 +
294 +The following is the display information on the serial port and the server.
295 +
296 +
297 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image017.png]]
298 +
299 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]]
300 +
301 +
302 +aM!,aMC!, aM1!- aM9!, aMC1!- aMC9!
303 +
304 +aM!: Start Non-Concurrent Measurement
305 +
306 +aMC!: Start Non-Concurrent Measurement – Request CRC
307 +
308 +aM1!- aM9!: Additional Measurements
309 +
310 +aMC1!- aMC9!: Additional Measurements – Request CRC
311 +
312 +
313 +* AT Command : AT+ADDRM=0,1,0,1
314 +* LoRaWAN Downlink(prefix 0xAA01): 0xAA 01 30 01 00 01
315 +
316 +Downlink:AA 01 aa bb cc dd
317 +
318 +aa: SDI-12 sensor address.
319 +
320 +bb: 0: no CRC, 1: request CRC
321 +
322 +cc: 1-9: Additional Measurement, 0: no additional measurement
323 +
324 +dd: delay (in second) to send **aD0!** to get return.
325 +
326 +
327 +The following is the display information on the serial port and the server.
328 +
329 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.png]]
330 +
331 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image020.png]]
332 +
333 +
334 +
335 +aC!, aCC!,  aC1!- aC9!,  aCC1!- aCC9!
336 +
337 +aC!: Start Concurrent Measurement
338 +
339 +aCC!: Start Concurrent Measurement – Request CRC
340 +
341 +aC1!- aC9!: Start Additional Concurrent Measurements
342 +
343 +aCC1!- aCC9!: Start Additional Concurrent Measurements – Request CRC
344 +
345 +
346 +* AT Command : AT+ADDRC=0,1,0,1 
347 +
348 +* LoRaWAN Downlink(0xAA02): 0xAA 02 30 01 00 01
349 +
350 +Downlink: AA 02 aa bb cc dd
351 +
352 +aa: SDI-12 sensor address.
353 +
354 +bb: 0: no CRC, 1: request CRC
355 +
356 +cc: 1-9: Additional Measurement, 0: no additional measurement
357 +
358 +dd: delay (in second) to send **aD0!** to get return.
359 +
360 +
361 +The following is the display information on the serial port and the server.
362 +
363 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]]
364 +
365 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
366 +
367 +
368 +aR0!- aR9!,  aRC0!- aRC9!
369 +
370 +Start Continuous Measurement
371 +
372 +Start Continuous Measurement – Request CRC
373 +
374 +
375 +* AT Command : AT+ADDRR=0,1,0,1 
376 +* LoRaWAN Downlink (0xAA 03): 0xAA 03 30 01 00 01
377 +
378 +Downlink: AA 03 aa bb cc dd
379 +
380 +aa: SDI-12 sensor address.
381 +
382 +bb: 0: no CRC, 1: request CRC
383 +
384 +cc: 1-9: Additional Measurement, 0: no additional measurement
385 +
386 +dd: delay (in second) to send **aD0!** to get return.
387 +
388 +
389 +The following is the display information on the serial port and the server.
390 +
391 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
392 +
393 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
394 +
395 +1.
396 +11.
397 +111. Advance SDI-12 Debug command
398 +
399 +This command can be used to debug all SDI-12 command.
400 +
401 +
402 +LoRaWAN Downlink: A8 aa xx xx xx xx bb cc
403 +
404 +(aa: total SDI-12 command length)
405 +
406 +(xx: SDI-12 command)
407 +
408 +(bb: Delay to wait for return)
409 +
410 +(cc: 0: don’t uplink return to LoRaWAN, 1: Uplink return to LoRaWAN on FPORT=100)
411 +
412 +
413 +Example: AT+CFGDEV =0RC0!,1
414 +
415 +0RC0!: SDI-12 Command,
416 +
417 +1: Delay 1 second.  ( 0: 810 mini-second)
418 +
419 +
420 +Equal Downlink: 0xA8 05 30 52 43 30 21 01 01
421 +
422 +
423 +The following is the display information on the serial port and the server.
424 +
425 +
426 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
427 +
428 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
429 +
430 +1.
431 +11.
432 +111. Convert ASCII to String
433 +
434 +This command is used to convert between ASCII and String format.
435 +
436 +
437 +AT+CONVFORM ( Max length: 80 bytes)
438 +
439 +Example:
440 +
441 +1)AT+CONVFORM=0,string   Convert String from String to ASCII
442 +
443 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
444 +
445 +
446 +2)AT+CONVFORM=1,ASCII   Convert ASCII to String.
447 +
448 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
449 +
450 +
451 +
452 +1.
453 +11.
454 +111. Define periodically SDI-12 commands and uplink.
455 +
456 +AT+COMMANDx & AT+DATACUTx
457 +
458 +User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB will then combine these returns and uplink via LoRaWAN.
459 +
460 +
461 +* ** AT Command:**
462 +
463 +**AT+COMMANDx=var1,var2,var3,var4.**
464 +
465 +var1: SDI-12 command , for example: 0RC0!
466 +
467 +var2: Wait timeout for return. (unit: second)
468 +
469 +var3: Whether to send //addrD0!// to get return after var2 timeout. 0: Don’t Send //addrD0!//; 1: Send //addrD0!//.
470 +
471 +var4: validation check for return. If return invalid, SDI-12-LB will resend this command. Max 2 retries.
472 +
473 +0  No validation check;
474 +
475 +1  Check if return chars are printable char(0x20 ~~ 0x7E);
476 +
477 +2  Check if there is return from SDI-12 sensor
478 +
479 +3  Check if return pass CRC check ( SDI-12 command var1 must include CRC request);
480 +
481 +
482 +Each AT+COMMANDx is followed by a **AT+DATACUT** command. AT+DATACUT command is used to take the useful string from the SDI-12 sensor so the final payload will have the minimum length to uplink.
483 +
484 +
485 +**AT+DATACUTx** : This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes.
486 +
487 +|(((
488 +AT+DATACUTx=a,b,c
489 +
490 +a: length for the return of AT+COMMAND
491 +
492 +b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.
493 +
494 +c: define the position for valid value. 
495 +)))
496 +
497 +
498 +For example, if return from AT+COMMAND1 is “013METER   TER12 112T12-00024895” ,. Below AT+DATACUT1 will get different result to combine payload:
499 +
500 +
501 +|AT+DATACUT1 value|Final Result to combine Payload
502 +|34,1,1+2+3|0D 00 01 30 31 33
503 +|34,2,1~~8+12~~16|0D 00 01 30 31 33 4D 45 54 45 52 54 45 52 31 32
504 +|34,2,1~~34|0D 00 01 30 31 33 4D 45 54 45 52 20 20 20 54 45 52 31 32 20 31 31 32 54 31 32 2D 30 30 30 32 34 38 39 35 0D 0A
505 +
506 +
507 +
508 +* ** Downlink Payload:**
509 +
510 +**0xAF**  downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
511 +
512 +
513 +**Note : if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
514 +
515 +
516 +Format: ** AF MM NN LL XX XX XX XX YY**
517 +
518 +Where:
519 +
520 +* MM: the AT+COMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
521 +* NN:  1: set the AT+DATACUT value ; 2: set the AT+DATACUT value.
522 +* LL:  The length of AT+COMMAND or AT+DATACUT command
523 +* XX XX XX XX: AT+COMMAND or AT+DATACUT command
524 +* YY:  If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 
525 +
526 +Example:
527 +
528 +**AF 03 01 07 30 4D 43 21 01 01 01 00**: Same as AT+COMMAND3=**0MC!**,** 1**,** 1**,** 1**
529 +
530 +**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10**
531 +
532 +**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10**
533 +
534 +
535 +**Clear SDI12 Command**
536 +
537 +The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
538 +
539 +
540 +* ** AT Command:**
541 +
542 +**~ AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
543 +
544 +
545 +Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
546 +
547 +
548 +* ** Downlink Payload:**
549 +
550 +**~ 0x09 aa bb**  same as AT+CMDEAR=aa,bb
551 +
552 +
553 +
554 +
555 +**command combination**
556 +
557 +Below shows a screen shot how the results combines together to a uplink payload.
558 +
559 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
560 +
561 +
562 +If user don’t want to use DATACUT for some command, he simply want to uplink all returns. AT+ALLDATAMOD can be set to 1.
563 +
564 +**AT+ALLDATAMOD** will simply get all return and don’t do CRC check as result for SDI-12 command. AT+DATACUTx command has higher priority, if AT+DATACUTx has been set, AT+ALLDATAMOD will be ignore for this SDI-12 command.
565 +
566 +
567 +For example: as below photo, AT+ALLDATAMOD=1, but AT+DATACUT1 has been set, AT+DATACUT1 will be still effect the result.
568 +
569 +
570 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]
571 +
572 +
573 +If AT+ALLDATAMOD=1, **FX,X** will be added in the payload, FX specify which command is used and X specify the length of return. for example in above screen, F1 05 means the return is from AT+COMMAND1 and the return is 5 bytes.
574 +
575 +
576 +
577 +**Compose Uplink**
578 +
579 +**AT+DATAUP=0**
580 +
581 +Compose the uplink payload with value returns in sequence and send with A SIGNLE UPLINK.
582 +
583 +Final Payload is Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
584 +
585 +Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
586 +
587 +
588 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]]
589 +
590 +
591 +**AT+DATAUP=1**
592 +
593 +Compose the uplink payload with value returns in sequence and send with Multiply UPLINKs.
594 +
595 +Final Payload is
596 +
597 +**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
598 +
599 +1. Battery Info (2 bytes): Battery voltage
600 +1. PAYVER (1 byte): Defined by AT+PAYVER
601 +1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
602 +1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
603 +1. DATA: Valid value: max 6 bytes(US915 version here, Notice*!) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes
604 +
605 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]]
606 +
607 +
608 +**Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:**
609 +
610 + ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
611 +
612 + * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
613 +
614 + * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
615 +
616 + ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
617 +
618 + *** When AT+DATAUP=1, the maximum number of segments is 15, and the maximum total number of bytes is 1500;**
619 +
620 +**~ When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**
621 +
622 +1.
623 +11. Uplink Payload
624 +
625 +
626 +Uplink payloads have two types:
627 +
628 +* Distance Value: Use FPORT=2
629 +* Other control commands: Use other FPORT fields.
630 +
631 +The application server should parse the correct value based on FPORT settings.
632 +
633 +
634 +1.
635 +11.
636 +111. Device Payload, FPORT=5
637 +
638 +Include device configure status. Once SDI-12-LB Joined the network, it will uplink this message to the server.
639 +
640 +
641 +Users can also use the downlink command(0x26 01) to ask SDI-12-LB to resend this uplink.
642 +
643 +
644 +|(% colspan="6" %)**Device Status (FPORT=5)**
645 +|**Size (bytes)**|**1**|**2**|**1**|**1**|**2**
646 +|**Value**|Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT
647 +
648 +
649 +Example parse in TTNv3
650 +
651 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]]
652 +
653 +**Sensor Model**: For SDI-12-LB, this value is 0x17
654 +
655 +**Firmware Version**: 0x0100, Means: v1.0.0 version
656 +
657 +**Frequency Band**:
658 +
659 +*0x01: EU868
660 +
661 +*0x02: US915
662 +
663 +*0x03: IN865
664 +
665 +*0x04: AU915
666 +
667 +*0x05: KZ865
668 +
669 +*0x06: RU864
670 +
671 +*0x07: AS923
672 +
673 +*0x08: AS923-1
674 +
675 +*0x09: AS923-2
676 +
677 +*0x0a: AS923-3
678 +
679 +*0x0b: CN470
680 +
681 +*0x0c: EU433
682 +
683 +*0x0d: KR920
684 +
685 +*0x0e: MA869
686 +
687 +
688 +**Sub-Band**:
689 +
690 +AU915 and US915:value 0x00 ~~ 0x08
691 +
692 +CN470: value 0x0B ~~ 0x0C
693 +
694 +Other Bands: Always 0x00
695 +
696 +
697 +**Battery Info**:
698 +
699 +Check the battery voltage.
700 +
701 +Ex1: 0x0B45 = 2885mV
702 +
703 +Ex2: 0x0B49 = 2889mV
704 +
705 +
706 +1.
707 +11.
708 +111. Uplink Payload, FPORT=2
709 +
710 +
711 +There are different cases for uplink. See below
712 +
713 +* SDI-12 Debug Command return: FPORT=100
714 +
715 +* Periodically Uplink: FPORT=2
716 +
717 +
718 +|(((
719 +**Size**
720 +
721 +**(bytes)**
722 +)))|**2**|**1**|**Length depends on the return from the commands**
723 +|**Value**|(((
724 +Battery(mV)
725 +
726 +&
727 +
728 +Interrupt_Flag
729 +)))|[[PAYLOAD_VER>>path:#Probe_Model]]|(((
730 +If the valid payload is too long and exceed the maximum support
731 +
732 +Payload length in server,server will show payload not provided in the LoRaWAN server.
733 +)))
734 +
735 +
736 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]]
737 +
738 +
739 +
740 +1.
741 +11.
742 +111. Battery Info
743 +
744 +Check the battery voltage for SDI-12-LB.
745 +
746 +Ex1: 0x0B45 = 2885mV
747 +
748 +Ex2: 0x0B49 = 2889mV
749 +
750 +
751 +1.
752 +11.
753 +111. Interrupt Pin
754 +
755 +This data field shows if this packet is generated by **Interrupt Pin** or not. [[Click here>>path:#Int_mod]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal. See [[pin mapping>>path:#pins]].
756 +
757 +
758 +Example:
759 +
760 +Ex1: 0x0B45:0x0B&0x80= 0x00    Normal uplink packet.
761 +
762 +Ex2: 0x8B49:0x8B&0x80= 0x80    Interrupt Uplink Packet.
763 +
764 +
765 +1.
766 +11.
767 +111. Payload version
768 +
769 +
770 +
771 +
772 +
773 +
774 +
775 +1.
776 +11.
777 +111. ​Decode payload in The Things Network
778 +
779 +While using TTN network, you can add the payload format to decode the payload.
780 +
781 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]]
782 +
783 +
784 +There is no fix payload decoder in LoRaWAN server because the SDI-12 sensors returns are different. User need to write the decoder themselves for their case.
785 +
786 +
787 +下面的解码生成超链接放进去.
788 +
789 +function Decoder(bytes, port) {
790 +
791 + if(port==5)
792 +
793 + {
794 +
795 + var freq_band;
796 +
797 + var sub_band;
798 +
799 + var sensor;
800 +
801 +
802 + if(bytes[0]==0x17)
803 +
804 + sensor= "SDI12-LB";
805 +
806 +
807 + var firm_ver= (bytes[1]&0x0f)+'.'+(bytes[2]>>4&0x0f)+'.'+(bytes[2]&0x0f);
808 +
809 +
810 + if(bytes[3]==0x01)
811 +
812 + freq_band="EU868";
813 +
814 + else if(bytes[3]==0x02)
815 +
816 + freq_band="US915";
817 +
818 + else if(bytes[3]==0x03)
819 +
820 + freq_band="IN865";
821 +
822 + else if(bytes[3]==0x04)
823 +
824 + freq_band="AU915";
825 +
826 + else if(bytes[3]==0x05)
827 +
828 + freq_band="KZ865";
829 +
830 + else if(bytes[3]==0x06)
831 +
832 + freq_band="RU864";
833 +
834 + else if(bytes[3]==0x07)
835 +
836 + freq_band="AS923";
837 +
838 + else if(bytes[3]==0x08)
839 +
840 + freq_band="AS923_1";
841 +
842 + else if(bytes[3]==0x09)
843 +
844 + freq_band="AS923_2";
845 +
846 + else if(bytes[3]==0x0A)
847 +
848 + freq_band="AS923_3";
849 +
850 + else if(bytes[3]==0x0F)
851 +
852 + freq_band="AS923_4";
853 +
854 + else if(bytes[3]==0x0B)
855 +
856 + freq_band="CN470";
857 +
858 + else if(bytes[3]==0x0C)
859 +
860 + freq_band="EU433";
861 +
862 + else if(bytes[3]==0x0D)
863 +
864 + freq_band="KR920";
865 +
866 + else if(bytes[3]==0x0E)
867 +
868 + freq_band="MA869";
869 +
870 +
871 + if(bytes[4]==0xff)
872 +
873 + sub_band="NULL";
874 +
875 + else
876 +
877 + sub_band=bytes[4];
878 +
879 +
880 + var bat= (bytes[5]<<8 | bytes[6])/1000;
881 +
882 +
883 + return {
884 +
885 + SENSOR_MODEL:sensor,
886 +
887 + FIRMWARE_VERSION:firm_ver,
888 +
889 + FREQUENCY_BAND:freq_band,
890 +
891 + SUB_BAND:sub_band,
892 +
893 + BAT:bat,
894 +
895 + }
896 +
897 + }
898 +
899 + else if(port==100)
900 +
901 + {
902 +
903 + var datas_sum={};
904 +
905 + for(var j=0;j<bytes.length;j++)
906 +
907 + {
908 +
909 + var datas= String.fromCharCode(bytes[j]);
910 +
911 + if(j=='0')
912 +
913 + datas_sum.datas_sum=datas;
914 +
915 + else
916 +
917 + datas_sum.datas_sum+=datas;
918 +
919 + }
920 +
921 +
922 + return datas_sum;
923 +
924 + }
925 +
926 + else
927 +
928 + {
929 +
930 + var decode={};
931 +
932 + decode.EXTI_Trigger= (bytes[0] & 0x80)? "TRUE":"FALSE";  
933 +
934 + decode.BatV= ((bytes[0]<<8 | bytes[1])&0x7FFF)/1000;
935 +
936 + decode.Payver= bytes[2];
937 +
938 + for(var i=3;i<bytes.length;i++)
939 +
940 + {
941 +
942 + var data= String.fromCharCode(bytes[i]);
943 +
944 + if(i=='3')
945 +
946 + decode.data_sum=data;
947 +
948 + else
949 +
950 + decode.data_sum+=data;
951 +
952 + }
953 +
954 + return decode; 
955 +
956 + }
957 +
958 +
959 +}
960 +
961 +
962 +1.
963 +11. Uplink Interval
964 +
965 +The SDI-12-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
966 +
967 +[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
968 +
969 +
970 +
971 +1.
972 +11. Frequency Plans
973 +
974 +The SDI12-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
975 +
976 +
977 +[[https:~~/~~/wiki.dragino.com/index.php?title=End_Device_Frequency_Band>>url:https://wiki.dragino.com/index.php?title=End_Device_Frequency_Band]]
978 +
979 +
980 +
981 +1.
982 +11. Firmware Change Log
983 +
984 +**Firmware download link:**
985 +
986 +[[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
987 +
988 +
989 +
990 +1. Configure SDI-12-LB via AT Command or LoRaWAN Downlink
991 +
992 +Use can configure SDI-12-LB via AT Command or LoRaWAN Downlink.
993 +
994 +* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
995 +* LoRaWAN Downlink instruction for different platforms:
996 +
997 +[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
998 +
999 +
1000 +There are two kinds of commands to configure SDI-12-LB, they are:
1001 +
1002 +* **General Commands**.
1003 +
1004 +These commands are to configure:
1005 +
1006 +* General system settings like: uplink interval.
1007 +* LoRaWAN protocol & radio related command.
1008 +
1009 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
1010 +
1011 +[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
1012 +
1013 +
1014 +* **Commands special design for SDI-12-LB**
1015 +
1016 +These commands only valid for SDI-12-LB, as below:
1017 +
1018 +
1019 +
1020 +1.
1021 +11. Set Transmit Interval Time
1022 +
1023 +Feature: Change LoRaWAN End Node Transmit Interval.
1024 +
1025 +**AT Command: AT+TDC**
1026 +
1027 +|**Command Example**|**Function**|**Response**
1028 +|AT+TDC=?|Show current transmit Interval|(((
1029 +30000
1030 +
1031 +OK
1032 +
1033 +the interval is 30000ms = 30s
1034 +)))
1035 +|AT+TDC=60000|Set Transmit Interval|(((
1036 +OK
1037 +
1038 +Set transmit interval to 60000ms = 60 seconds
1039 +)))
1040 +
1041 +
1042 +**Downlink Command: 0x01**
1043 +
1044 +Format: Command Code (0x01) followed by 3 bytes time value.
1045 +
1046 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1047 +
1048 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1049 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1050 +
1051 +
1052 +
1053 +1.
1054 +11. Set Interrupt Mode
1055 +
1056 +Feature, Set Interrupt mode for GPIO_EXIT.
1057 +
1058 +**AT Command: AT+INTMOD**
1059 +
1060 +|**Command Example**|**Function**|**Response**
1061 +|AT+INTMOD=?|Show current interrupt mode|(((
1062 +0
1063 +
1064 +OK
1065 +
1066 +the mode is 0 = No interruption
1067 +)))
1068 +|AT+INTMOD=2|(((
1069 +Set Transmit Interval
1070 +
1071 +1. (Disable Interrupt),
1072 +1. (Trigger by rising and falling edge),
1073 +1. (Trigger by falling edge)
1074 +1. (Trigger by rising edge)
1075 +)))|OK
1076 +
1077 +
1078 +**Downlink Command: 0x06**
1079 +
1080 +Format: Command Code (0x06) followed by 3 bytes.
1081 +
1082 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1083 +
1084 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1085 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1086 +
1087 +
1088 +1.
1089 +11. Set the output time
1090 +
1091 +Feature, Control the output 3V3 , 5V or 12V.
1092 +
1093 +**AT Command: AT+3V3T**
1094 +
1095 +|**Command Example**|**Function**|**Response**
1096 +|AT+3V3T=?|Show 3V3 open time.|(((
1097 +0
1098 +
1099 +OK
1100 +)))
1101 +|AT+3V3T=0|Normally open 3V3 power supply.|(((
1102 +OK
1103 +
1104 +default setting
1105 +)))
1106 +|AT+3V3T=1000|Close after a delay of 1000 milliseconds.|(((
1107 +OK
1108 +
1109 +
1110 +)))
1111 +|AT+3V3T=65535|Normally closed 3V3 power supply.|(((
1112 +OK
1113 +
1114 +
1115 +)))
1116 +
1117 +
1118 +**AT Command: AT+5VT**
1119 +
1120 +|**Command Example**|**Function**|**Response**
1121 +|AT+5VT=?|Show 5V open time.|(((
1122 +0
1123 +
1124 +OK
1125 +)))
1126 +|AT+5VT=0|Normally closed 5V power supply.|(((
1127 +OK
1128 +
1129 +default setting
1130 +)))
1131 +|AT+5VT=1000|Close after a delay of 1000 milliseconds.|(((
1132 +OK
1133 +
1134 +
1135 +)))
1136 +|AT+5VT=65535|Normally open 5V power supply.|(((
1137 +OK
1138 +
1139 +
1140 +)))
1141 +
1142 +
1143 +**AT Command: AT+12VT**
1144 +
1145 +|**Command Example**|**Function**|**Response**
1146 +|AT+12VT=?|Show 12V open time.|(((
1147 +0
1148 +
1149 +OK
1150 +)))
1151 +|AT+12VT=0|Normally closed 12V power supply.|OK
1152 +|AT+12VT=500|Close after a delay of 500 milliseconds.|(((
1153 +OK
1154 +
1155 +
1156 +)))
1157 +
1158 +
1159 +**Downlink Command: 0x07**
1160 +
1161 +Format: Command Code (0x07) followed by 3 bytes.
1162 +
1163 +The first byte is which power, the second and third bytes are the time to turn on.
1164 +
1165 +* Example 1: Downlink Payload: 070101F4  -> AT+3V3T=500
1166 +* Example 2: Downlink Payload: 0701FFFF   -> AT+3V3T=65535
1167 +* Example 3: Downlink Payload: 070203E8  -> AT+5VT=1000
1168 +* Example 4: Downlink Payload: 07020000  -> AT+5VT=0
1169 +* Example 5: Downlink Payload: 070301F4  -> AT+12VT=500
1170 +* Example 6: Downlink Payload: 07030000  -> AT+12VT=0
1171 +
1172 +
1173 +1.
1174 +11. Set the all data mode
1175 +
1176 +Feature, Set the all data mode.
1177 +
1178 +**AT Command: AT+ALLDATAMOD**
1179 +
1180 +|**Command Example**|**Function**|**Response**
1181 +|AT+ALLDATAMOD=?|Show current all data mode|(((
1182 +0
1183 +
1184 +
1185 +OK
1186 +)))
1187 +|AT+ALLDATAMOD=1|Set all data mode is 1.|OK
1188 +
1189 +
1190 +**Downlink Command: 0xAB**
1191 +
1192 +Format: Command Code (0xAB) followed by 1 bytes.
1193 +
1194 +* Example 1: Downlink Payload: AB 00 ~/~/ AT+ALLDATAMOD=0
1195 +* Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1
1196 +
1197 +
1198 +1.
1199 +11. Set the splicing payload for uplink
1200 +
1201 +Feature, splicing payload for uplink.
1202 +
1203 +**AT Command: AT+DATAUP**
1204 +
1205 +|**Command Example**|**Function**|**Response**
1206 +|AT+DATAUP =?|Show current splicing payload for uplink mode|(((
1207 +0
1208 +
1209 +
1210 +OK
1211 +)))
1212 +|AT+DATAUP =0|(((
1213 +Set splicing payload for uplink mode is 0.
1214 +
1215 +
1216 +)))|(((
1217 +OK
1218 +
1219 +
1220 +)))
1221 +|AT+DATAUP =1|Set splicing payload for uplink mode is 1 , and the each splice uplink is sent sequentially.|OK
1222 +|AT+DATAUP =1,20000|(((
1223 +Set splicing payload for uplink mode is 1, and the uplink interval of each splice to 20000 milliseconds.
1224 +
1225 +
1226 +)))|OK
1227 +
1228 +
1229 +**Downlink Command: 0xAD**
1230 +
1231 +Format: Command Code (0xAD) followed by 1 bytes or 5 bytes.
1232 +
1233 +* Example 1: Downlink Payload: AD 00 ~/~/ AT+DATAUP=0
1234 +* Example 2: Downlink Payload: AD 01 ~/~/ AT+DATAUP =1
1235 +* Example 3: Downlink Payload: AD 01 00 00 14~/~/ AT+DATAUP =1,20000
1236 +
1237 +This means that the interval is set to 0x000014=20S
1238 +
1239 +
1240 +1.
1241 +11. Set the payload version
1242 +
1243 +Feature, Set the payload version.
1244 +
1245 +**AT Command: AT+PAYVER**
1246 +
1247 +|**Command Example**|**Function**|**Response**
1248 +|AT+PAYVER=?|Show current payload version|(((
1249 +1
1250 +
1251 +
1252 +OK
1253 +)))
1254 +|AT+PAYVER=5|Set payload version is 5.|OK
1255 +
1256 +
1257 +**Downlink Command: 0xAE**
1258 +
1259 +Format: Command Code (0xAE) followed by 1 bytes.
1260 +
1261 +* Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1
1262 +* Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5
1263 +
1264 +
1265 +
1266 +1. Battery & how to replace
1267 +11. Battery Type
1268 +
1269 +SDI-12-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1270 +
1271 +
1272 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1273 +
1274 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1275 +
1276 +
1277 +Minimum Working Voltage for the SDI-12-LB:
1278 +
1279 +SDI-12-LB:  2.45v ~~ 3.6v
1280 +
1281 +
1282 +1.
1283 +11. Replace Battery
1284 +
1285 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1286 +
1287 +And make sure the positive and negative pins match.
1288 +
1289 +
1290 +
1291 +1.
1292 +11. Power Consumption Analyze
1293 +
1294 +
1295 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1296 +
1297 +
1298 +Instruction to use as below:
1299 +
1300 +
1301 +Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1302 +
1303 +[[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1304 +
1305 +
1306 +Step 2: Open it and choose
1307 +
1308 +* Product Model
1309 +* Uplink Interval
1310 +* Working Mode
1311 +
1312 +And the Life expectation in difference case will be shown on the right.
1313 +
1314 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image037.png]]
1315 +
1316 +
1317 +The battery related documents as below:
1318 +
1319 +* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1320 +* [[Lithium-Thionyl Chloride Battery>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/ER18505_datasheet-EN.pdf]] datasheet, [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/ER18505_datasheet_PM-ER18505-S-02-LF_EN.pdf]]
1321 +* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1322 +
1323 +
1324 +
1325 +|(((
1326 +JST-XH-2P connector
1327 +)))
1328 +
1329 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image038.png]]
1330 +
1331 +
1332 +
1333 +1.
1334 +11.
1335 +111. ​Battery Note
1336 +
1337 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1338 +
1339 +
1340 +1.
1341 +11.
1342 +111. ​Replace the battery
1343 +
1344 +You can change the battery in the SDI-12-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1345 +
1346 +
1347 +The default battery pack of SDI-12-LB includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1348 +
1349 +
1350 +
1351 +
1352 +
1353 +
1354 +1. Remote Configure device
1355 +11. Connect via BLE
1356 +
1357 +
1358 +Please see this instruction for how to configure via BLE:
1359 +
1360 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]
1361 +
1362 +
1363 +1.
1364 +11. AT Command Set
1365 +
1366 +
1367 +
1368 +1. OTA firmware update
1369 +
1370 +Please see this link for how to do OTA firmware update.
1371 +
1372 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
1373 +
1374 +
1375 +
1376 +
1377 +
1378 +
1379 +
1380 +
1381 +
1382 +
1383 +
1384 +1. ​Order Info
1385 +
1386 +**Package Includes**:
1387 +
1388 +* SDI-12-LB SDI-12 to LoRaWAN Converter
1389 +
1390 +
1391 +**Dimension and weight**:
1392 +
1393 +* Device Size: cm
1394 +* Device Weight: g
1395 +* Package Size / pcs : cm
1396 +* Weight / pcs : g
1397 +
1398 +
1399 +
1400 +
1401 +
1402 +1. ​Support
1403 +
1404 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1405 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
1406 +
1407 +[[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
1408 +
1409 +
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0