Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 174.1
edited by Mengting Qiu
on 2025/06/13 15:06
on 2025/06/13 15:06
Change comment:
There is no comment for this version
To version 171.1
edited by Mengting Qiu
on 2025/06/09 14:13
on 2025/06/09 14:13
Change comment:
Uploaded new attachment "image-20250609141343-1.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,7 @@ 1 1 2 2 3 -[[image:image-20240103165259-3.png||data-xwiki-image-style-alignment="center" height="433" width="591"]] 3 +(% style="text-align:center" %) 4 +[[image:image-20240103165259-3.png||height="433" width="591"]] 4 4 5 5 6 6 ... ... @@ -138,16 +138,16 @@ 138 138 139 139 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 140 140 |=(% style="width: 167px;background-color:#4F81BD;color:white" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 226px;background-color:#4F81BD;color:white" %)**Action** 141 -| [[image:1749523850351-927.png]]1~~3s|(% style="background-color:#f2f2f2; width:117px" %)Send an uplink|(% style="background-color:#f2f2f2; width:225px" %)(((142 +|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Send an uplink|(% style="background-color:#f2f2f2; width:225px" %)((( 142 142 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once. 143 143 Meanwhile, BLE module will be active and user can connect via BLE to configure device. 144 144 ))) 145 -| [[image:1749523852387-583.png]]>3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)(((146 +|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 146 146 (% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. 147 147 (% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 148 148 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 149 149 ))) 150 -| [[image:1749523825515-716.png]]x5|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means SDI-12-LB/LS is in Deep Sleep Mode.151 +|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means SDI-12-LB/LS is in Deep Sleep Mode. 151 151 152 152 == 1.7 Pin Mapping == 153 153 ... ... @@ -512,7 +512,7 @@ 512 512 513 513 (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.(since v1.3.0)** 514 514 515 -(% style="color:red" %)**(Function set to 2: When the device is connected to more than two sensors with different sampling addresses, concurrent measurement can be used to reduce data acquisition time and save battery power; for example, when adevice is connected to two sensors with different addresses,and bothsensorsare to useconcurrent measurements,thenboth sensorscan bemeasured atthesametimewithoutthesecondonehavingtowaituntilafterthefirstone.)**516 +(% style="color:red" %)**(Function set to 2: When the device is connected to more than two sensors with different sampling addresses, concurrent measurement can be used to reduce data acquisition time and save battery power; for example, when the device is connected to two sensors with different addresses, the concurrent measurement function can be used and the two sensors can collect data at the same time.)** 516 516 517 517 (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries. 518 518 ... ... @@ -709,6 +709,8 @@ 709 709 * Example 1: Downlink Payload: AC 01 01 02 02 02 ~/~/ AT+DATACONV1=1,2+2,2 710 710 * Example 2: Downlink Payload: AC 02 01 02 02 02 03 02 ~/~/ AT+DATACONV2=1,2+2,2+3,2 711 711 713 + 714 + 712 712 **For example:** 713 713 714 714 This is my configuration: ... ... @@ -716,8 +716,8 @@ 716 716 [[image:image-20250609134137-1.png]] 717 717 718 718 719 -* AT+COMMAND1=0C!,0,2,0 Use concurrentmeasurementcommandswithout interceptingthereturned data.720 -* AT+COMMAND2=1C!,1,2,0 Use concurrent measurement commands withoutintercepting the returneddata,with asecondparametertobe setat thelastconcurrent command(thesecondparametertakesthemaximumtransition timebetween the two sensors)722 +* AT+COMMAND1=0C!,0,2,0 After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately. 723 +* AT+COMMAND2=1C!,1,2,0 After sending a concurrent command to device 1, do not truncate the data and wait for one second. (Concurrent commands will be sampled with the command with the longest waiting time; for example, if the waiting time in the current device is set to 1s, the concurrent command will default to a maximum waiting time of 1s.) 721 721 * AT+COMMAND3=0D0!,0,0,0 Query the data measured by device 0 722 722 * AT+COMMAND4=1D0!,0,0,0 Query the data measured by device 1 723 723 ... ... @@ -735,27 +735,19 @@ 735 735 AT+DATACONV4=1,3+2,2+3,2 The first data uploads 3 bytes, the second data also uploads 2 bytes, and the third data also uploads 2 bytes. The hexadecimal form is shown above and as shown in the following figure: 736 736 ))) 737 737 738 -[[image:image-202506 09141343-1.png]]741 +[[image:image-20250516144559-1.png]] 739 739 740 - **Forexample,theuplinkpayload as below:**743 +0C90 01 005F 0104 741 741 742 - 0CE40100C6010302DB9900FD0001745 +(% style="color:#037691" %)**BAT**(%%): 0x0c90 = 3216mV = 3.216V 743 743 744 -(% style="color:#037691" %)**BAT**(%%): 0x0CE4 = 3300mV = 3.300V 745 - 746 746 (% style="color:#037691" %)**Payload Version**(%%): 0x01, Means: v1.0 version 747 747 748 -(% style="color:#037691" %)**Data 1: **(%%)0x00 C6(H) =198(D) / 100 =19.8749 +(% style="color:#037691" %)**Data 1: **(%%)0x005F(H) = 95(D) / 100 = 0.95 749 749 750 -(% style="color:#037691" %)**Data 2: **(%%)0x010 3(H) = 259(D) / 10 = 25.9751 +(% style="color:#037691" %)**Data 2: **(%%)0x0104(H) = 260(D) / 10 = 26.0 751 751 752 -(% style="color:#037691" %)**Data 3: **(%%)0x02DB99(H) = 187289(D) / 100 = 1872.89 753 753 754 -(% style="color:#037691" %)**Data 4: **(%%)0x00FD(H) = 253(D) / 10 = 25.3 755 - 756 -(% style="color:#037691" %)**Data 5: **(%%)0x0001(H) = 1(D) = 1 757 - 758 - 759 759 == 2.4 Uplink Payload == 760 760 761 761 === 2.4.1 Device Payload, FPORT~=5 === ... ... @@ -1861,9 +1861,6 @@ 1861 1861 1862 1862 * Example: 0xA90D09 ~/~/ Same as AT+SDITIMING=13,9 1863 1863 1864 - 1865 - 1866 - 1867 1867 == 3.11 add Pulse_count, VDC_input, IDC_input(Since firmware V1.3.0) == 1868 1868 1869 1869 ... ... @@ -1959,45 +1959,6 @@ 1959 1959 1960 1960 1961 1961 1962 -== 3.12 Cut data separation processing == 1963 - 1964 - 1965 -AT+NEWLINE command, which only takes effect when AT+DATAUP=1 or AT+DATAUP=1, timeout. 1966 - 1967 -When not set, each part of AT+DATAUP is sent according to the maximum number of bytes of DR. 1968 - 1969 -When setting, each part of AT+DATAUP is sent according to the value set by AT+NEWLINE. 1970 - 1971 - 1972 -* ((( 1973 -(% style="color:#037691" %)** AT Command:** 1974 -))) 1975 - 1976 -(% style="color:#4472c4" %)//**AT+NEWLINE=ALL**//(%%)// //The data cut out by each AT+COMMANDx command is sent separately as an uplink. 1977 - 1978 -(% style="color:#4472c4" %)//**AT+NEWLINE=ALL**//(%%)// equal: (% style="color:#4472c4" %)**AT+NEWLINE=1+2+3+4+5+6+7+8+9+10+11+12+13+14+15**// 1979 - 1980 - 1981 -(% style="color:#4472c4" %)//**AT+NEWLINE=a+b+c**//(%%)// //The data returned by all commands is divided into three parts, COMMAND(1~~a) is the first part, COMMAND(a+1~~b) is the second part,COMMAND(b+1~~c) is the third part. 1982 - 1983 - 1984 -(% style="color:#4472c4" %)//**AT+NEWLINE=NULL**//(%%)// //Turn off the functionality of this AT command. 1985 - 1986 - 1987 -* ((( 1988 -(% style="color:#037691" %)** Downlink Payload:** 1989 -))) 1990 - 1991 -//AT+NEWLINE=ALL ~-~--> (% style="color:#4472c4" %)**0xA5 01**// 1992 - 1993 -// AT+NEWLINE= NULL ~-~--> (% style="color:#4472c4" %)**0xA5 00**// 1994 - 1995 -//AT+NEWLINE= a+b+c ~-~--> (% style="color:#4472c4" %)**0xA5 number of bytes a b c**// 1996 - 1997 -//AT+NEWLINE= 1+5+15 ~-~--> (% style="color:#4472c4" %)**0xA5 03 01 05 0F**// 1998 - 1999 - 2000 - 2001 2001 = 4. Battery & Power Consumption = 2002 2002 2003 2003
- 1749523825515-716.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.4 KB - Content
- 1749523850351-927.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.9 KB - Content
- 1749523852387-583.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.9 KB - Content