Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 172.1
edited by Mengting Qiu
on 2025/06/09 14:22
on 2025/06/09 14:22
Change comment:
There is no comment for this version
To version 171.2
edited by Mengting Qiu
on 2025/06/09 14:18
on 2025/06/09 14:18
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -513,7 +513,7 @@ 513 513 514 514 (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.(since v1.3.0)** 515 515 516 -(% style="color:red" %)**(Function set to 2: When the device is connected to more than two sensors with different sampling addresses, concurrent measurement can be used to reduce data acquisition time and save battery power; for example, when adevice is connected to two sensors with different addresses,and bothsensorsare to useconcurrent measurements,thenboth sensorscan bemeasured atthesametimewithoutthesecondonehavingtowaituntilafterthefirstone.)**516 +(% style="color:red" %)**(Function set to 2: When the device is connected to more than two sensors with different sampling addresses, concurrent measurement can be used to reduce data acquisition time and save battery power; for example, when the device is connected to two sensors with different addresses, the concurrent measurement function can be used and the two sensors can collect data at the same time.)** 517 517 518 518 (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries. 519 519 ... ... @@ -718,8 +718,8 @@ 718 718 [[image:image-20250609134137-1.png]] 719 719 720 720 721 -* AT+COMMAND1=0C!,0,2,0 Use concurrentmeasurementcommandswithout interceptingthereturned data.722 -* AT+COMMAND2=1C!,1,2,0 Use concurrent measurement commands withoutintercepting the returneddata,with asecondparametertobe setat thelastconcurrent command(thesecondparametertakesthemaximumtransition timebetween the two sensors)721 +* AT+COMMAND1=0C!,0,2,0 After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately. 722 +* AT+COMMAND2=1C!,1,2,0 After sending a concurrent command to device 1, do not truncate the data and wait for one second. (Concurrent commands will be sampled with the command with the longest waiting time; for example, if the waiting time in the current device is set to 1s, the concurrent command will default to a maximum waiting time of 1s.) 723 723 * AT+COMMAND3=0D0!,0,0,0 Query the data measured by device 0 724 724 * AT+COMMAND4=1D0!,0,0,0 Query the data measured by device 1 725 725