... ... @@ -513,7 +513,7 @@
513 513  
514 514  (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.(since v1.3.0)**
515 515  
516 -(% style="color:red" %)**(Function set to 2: When the device is connected to more than two sensors with different sampling addresses, concurrent measurement can be used to reduce data acquisition time and save battery power; for example, when a device is connected to two sensors with different addresses, and both sensors are to use concurrent measurements, then both sensors can be measured at the same time without the second one having to wait until after the first one.)**
516 +(% style="color:red" %)**(Function set to 2: When the device is connected to more than two sensors with different sampling addresses, concurrent measurement can be used to reduce data acquisition time and save battery power; for example, when the device is connected to two sensors with different addresses, the concurrent measurement function can be used and the two sensors can collect data at the same time.)**
517 517  
518 518  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
519 519  
... ... @@ -711,6 +711,7 @@
711 711  * Example 2: Downlink Payload: AC 02 01 02 02 02 03 02  ~/~/  AT+DATACONV2=1,2+2,2+3,2
712 712  
713 713  
714 +
714 714  **For example:**
715 715  
716 716  This is my configuration:
... ... @@ -718,8 +718,8 @@
718 718  [[image:image-20250609134137-1.png]]
719 719  
720 720  
721 -* AT+COMMAND1=0C!,0,2,0  Use concurrent measurement commands without intercepting the returned data.
722 -* AT+COMMAND2=1C!,1,2,0  Use concurrent measurement commands without intercepting the returned data, with a second parameter to be set at the last concurrent command (the second parameter takes the maximum transition time between the two sensors)
722 +* AT+COMMAND1=0C!,0,2,0  After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately.
723 +* AT+COMMAND2=1C!,1,2,0  After sending a concurrent command to device 1, do not truncate the data and wait for one second. (Concurrent commands will be sampled with the command with the longest waiting time; for example, if the waiting time in the current device is set to 1s, the concurrent command will default to a maximum waiting time of 1s.)
723 723  * AT+COMMAND3=0D0!,0,0,0  Query the data measured by device 0
724 724  * AT+COMMAND4=1D0!,0,0,0  Query the data measured by device 1
725 725  
... ... @@ -737,27 +737,19 @@
737 737  AT+DATACONV4=1,3+2,2+3,2  The first data uploads 3 bytes, the second data also uploads 2 bytes, and the third data also uploads 2 bytes. The hexadecimal form is shown above and as shown in the following figure:
738 738  )))
739 739  
740 -[[image:image-20250609141343-1.png]]
741 +[[image:image-20250516144559-1.png]]
741 741  
742 -**For example,the uplink payload as below:**
743 +0C90 01 005F 0104
743 743  
744 -0CE4 01 00C6 0103 02DB99 00FD 0001
745 +(% style="color:#037691" %)**BAT**(%%): 0x0c90 = 3216mV = 3.216V
745 745  
746 -(% style="color:#037691" %)**BAT**(%%): 0x0CE4 = 3300mV = 3.300V
747 -
748 748  (% style="color:#037691" %)**Payload Version**(%%): 0x01, Means: v1.0 version
749 749  
750 -(% style="color:#037691" %)**Data 1: **(%%)0x00C6(H) = 198(D) / 100 = 19.8
749 +(% style="color:#037691" %)**Data 1: **(%%)0x005F(H) = 95(D) / 100 = 0.95
751 751  
752 -(% style="color:#037691" %)**Data 2: **(%%)0x0103(H) = 259(D) / 10 = 25.9
751 +(% style="color:#037691" %)**Data 2: **(%%)0x0104(H) = 260(D) / 10 = 26.0
753 753  
754 -(% style="color:#037691" %)**Data 3: **(%%)0x02DB99(H) = 187289(D) / 100 = 1872.89
755 755  
756 -(% style="color:#037691" %)**Data 4: **(%%)0x00FD(H) = 253(D) / 10 = 25.3
757 -
758 -(% style="color:#037691" %)**Data 5: **(%%)0x0001(H) = 1(D) = 1
759 -