... ... @@ -513,7 +513,7 @@
513 513  
514 514  (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.(since v1.3.0)**
515 515  
516 -(% style="color:red" %)**(Function set to 2: When the device is connected to more than two sensors with different sampling addresses, concurrent measurement can be used to reduce data acquisition time and save battery power; for example, when the device is connected to two sensors with different addresses, the concurrent measurement function can be used and the two sensors can collect data at the same time.)**
516 +(% style="color:red" %)**(Function set to 2: When the device is connected to more than two sensors with different sampling addresses, concurrent measurement can be used to reduce data acquisition time and save battery power; for example, when a device is connected to two sensors with different addresses, and both sensors are to use concurrent measurements, then both sensors can be measured at the same time without the second one having to wait until after the first one.)**
517 517  
518 518  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
519 519  
... ... @@ -711,21 +711,21 @@
711 711  * Example 2: Downlink Payload: AC 02 01 02 02 02 03 02  ~/~/  AT+DATACONV2=1,2+2,2+3,2
712 712  
713 713  
714 -
715 715  **For example:**
716 716  
717 717  This is my configuration:
718 718  
719 -[[image:image-20250605091006-1.png]]
718 +[[image:image-20250609134137-1.png]]
720 720  
721 721  
722 -* AT+COMMAND1=0C!,0,2,0  After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately.
723 -* AT+COMMAND2=0M!,1,2,0  After sending the concurrent command of device 0, do not cut the data and wait for one second. (The last concurrent command needs to wait for the measurement time of all sensors)
724 -* AT+COMMAND3=0D0!,0,0,0  Query the data measured by device 0
721 +* AT+COMMAND1=0C!,0,2,0  Use concurrent measurement commands without intercepting the returned data.
722 +* AT+COMMAND2=1C!,1,2,0  Use concurrent measurement commands without intercepting the returned data, with a second parameter to be set at the last concurrent command (the second parameter takes the maximum transition time between the two sensors)
723 +* AT+COMMAND3=0D0!,0,0,0  Query the data measured by device 0
724 +* AT+COMMAND4=1D0!,0,0,0  Query the data measured by device 1
725 725  
726 726  This is the data obtained:
727 727  
728 -[[image:image-20250516145402-2.png]]
728 +[[image:image-20250609134901-2.png]]
729 729  
730 730  
731 731  When using the AT+DATACONVx command,
... ... @@ -733,20 +733,31 @@
733 733  The data of RETURN3 will be converted into 2 data, the first data is +95, and the second data is +260.
734 734  
735 735  * AT+DATACONV3=1,2+2,2  The first data is uploaded as 2 bytes and the second data is uploaded as 2 bytes. The form converted to hexadecimal is as shown above,as below:
736 +* (((
737 +AT+DATACONV4=1,3+2,2+3,2  The first data uploads 3 bytes, the second data also uploads 2 bytes, and the third data also uploads 2 bytes. The hexadecimal form is shown above and as shown in the following figure:
738 +)))
736 736  
737 -[[image:image-20250516144559-1.png]]
740 +[[image:image-20250609141343-1.png]]
738 738  
739 -0C90 01 005F 0104
742 +**For example,the uplink payload as below:**
740 740  
741 -(% style="color:#037691" %)**BAT**(%%): 0x0c90 3216mV = 3.216V
744 +0CE4 01 00C6 0103 02DB99 00FD 0001
742 742  
746 +(% style="color:#037691" %)**BAT**(%%): 0x0CE4 = 3300mV = 3.300V
747 +
743 743  (% style="color:#037691" %)**Payload Version**(%%): 0x01, Means: v1.0 version
744 744  
745 -(% style="color:#037691" %)**Data 1: **(%%)0x005F(H) = 95(D) / 100 = 0.95
750 +(% style="color:#037691" %)**Data 1: **(%%)0x00C6(H) = 198(D) / 100 = 19.8
746 746  
747 -(% style="color:#037691" %)**Data 2: **(%%)0x0104(H) = 260(D) / 10 = 26.0
752 +(% style="color:#037691" %)**Data 2: **(%%)0x0103(H) = 259(D) / 10 = 25.9
748 748  
754 +(% style="color:#037691" %)**Data 3: **(%%)0x02DB99(H) = 187289(D) / 100 = 1872.89
749 749  
756 +(% style="color:#037691" %)**Data 4: **(%%)0x00FD(H) = 253(D) / 10 = 25.3
757 +
758 +(% style="color:#037691" %)**Data 5: **(%%)0x0001(H) = 1(D) = 1
759 +
760 +
750 750  == 2.4 Uplink Payload ==
751 751  
752 752  === 2.4.1 Device Payload, FPORT~=5 ===
image-20250609134901-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +16.6 KB
Content
image-20250609141343-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +76.1 KB
Content