Last modified by Mengting Qiu on 2025/07/03 15:42

From version 167.1
edited by Mengting Qiu
on 2025/06/09 10:23
Change comment: There is no comment for this version
To version 164.1
edited by Mengting Qiu
on 2025/06/05 09:10
Change comment: Uploaded new attachment "image-20250605091006-1.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -513,8 +513,6 @@
513 513  
514 514  (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
515 515  
516 -(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)**
517 -
518 518  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
519 519  
520 520  (% style="color:red" %)**0 **(%%) No validation check;
... ... @@ -679,45 +679,12 @@
679 679  
680 680  (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
681 681  
682 -* (% style="color:blue" %)**Downlink Command:**
683 683  
684 -Format: Command code (0xAC) followed by up to 20 bytes.
685 -
686 -
687 -Example 1 1:AT+DATACONVx=var1, var2   
688 -
689 -Downlink Command:AC x var1  var2
690 -
691 -Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 
692 -
693 -Downlink Command:AC x var1  var2  var3 var4
694 -
695 -Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6
696 -
697 -Downlink Command:AC x var1  var2  var3 var4 var5 var6
698 -
699 -Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8
700 -
701 -Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8
702 -
703 -Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10
704 -
705 -Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8 var9 var10
706 -
707 -
708 -Example:
709 -
710 -* Example 1: Downlink Payload: AC 01 01 02 02 02  ~/~/  AT+DATACONV1=1,2+2,2 
711 -* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02  ~/~/  AT+DATACONV2=1,2+2,2+3,2
712 -
713 -
714 -
715 -
716 716  **For example:**
717 717  
718 718  This is my configuration:
719 719  
720 -[[image:image-20250605091006-1.png]]
685 +[[image:image-20250516103205-2.png]]
721 721  
722 722  
723 723  * AT+COMMAND1=0C!,0,2,0  After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately.
... ... @@ -1415,11 +1415,7 @@
1415 1415  
1416 1416  **SDI-12-LB will uplink this payload.**
1417 1417  
1418 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **
1419 -68253C5D 12 0C7801F10D302B312E31372B32372E340D0A
1420 -68253D33 12 0C7201F10D302B312E31352B32382E390D0A
1421 -68253DAB 12 0C7201F10D302B312E31342B32392E340D0A
1422 -68253E23 12 0C7201F10D302B312E31332B33302E300D0A
1383 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A
1423 1423  
1424 1424  
1425 1425  Where the first 23 bytes is for the first entry:
... ... @@ -1673,6 +1673,7 @@
1673 1673  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1674 1674  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1675 1675  
1637 +
1676 1676  == 3.7 Print data entries base on page(Since v1.3.0) ==
1677 1677  
1678 1678  
... ... @@ -1808,7 +1808,7 @@
1808 1808  No downlink commands for feature
1809 1809  
1810 1810  
1811 -== 3.9 Clear Flash Record(Since v1.3.0) ==
1773 +=== 3.9 Clear Flash Record(Since v1.3.0) ===
1812 1812  
1813 1813  
1814 1814  Feature: Clear flash storage for data log feature.