... ... @@ -513,8 +513,6 @@
513 513  
514 514  (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
515 515  
516 -(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)**
517 -
518 518  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
519 519  
520 520  (% style="color:red" %)**0 **(%%) No validation check;
... ... @@ -679,41 +679,7 @@
679 679  
680 680  (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
681 681  
682 -* (% style="color:blue" %)**Downlink Command:**
683 683  
684 -Format: Command code (0xAC) followed by up to 20 bytes.
685 -
686 -
687 -Example 1 1:AT+DATACONVx=var1, var2   
688 -
689 -Downlink Command:AC x var1  var2
690 -
691 -Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 
692 -
693 -Downlink Command:AC x var1  var2  var3 var4
694 -
695 -Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6
696 -
697 -Downlink Command:AC x var1  var2  var3 var4 var5 var6
698 -
699 -Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8
700 -
701 -Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8
702 -
703 -Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10
704 -
705 -Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8 var9 var10
706 -
707 -
708 -Example:
709 -
710 -* Example 1: Downlink Payload: AC 01 01 02 02 02  ~/~/  AT+DATACONV1=1,2+2,2 
711 -* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02  ~/~/  AT+DATACONV2=1,2+2,2+3,2
712 -
713 -
714 -
715 -
716 -
717 717  **For example:**
718 718  