Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 166.2
edited by Mengting Qiu
on 2025/06/07 09:44
on 2025/06/07 09:44
Change comment:
There is no comment for this version
To version 165.1
edited by Mengting Qiu
on 2025/06/05 09:10
on 2025/06/05 09:10
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -513,8 +513,6 @@ 513 513 514 514 (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)** 515 515 516 -(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)** 517 - 518 518 (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries. 519 519 520 520 (% style="color:red" %)**0 **(%%) No validation check; ... ... @@ -679,41 +679,7 @@ 679 679 680 680 (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.** 681 681 682 -* (% style="color:blue" %)**Downlink Command:** 683 683 684 -Format: Command code (0xAC) followed by up to 20 bytes. 685 - 686 - 687 -Example 1 1:AT+DATACONVx=var1, var2 688 - 689 -Downlink Command:AC x var1 var2 690 - 691 -Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 692 - 693 -Downlink Command:AC x var1 var2 var3 var4 694 - 695 -Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6 696 - 697 -Downlink Command:AC x var1 var2 var3 var4 var5 var6 698 - 699 -Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8 700 - 701 -Downlink Command:AC x var1 var2 var3 var4 var5 var6 var7 var8 702 - 703 -Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10 704 - 705 -Downlink Command:AC x var1 var2 var3 var4 var5 var6 var7 var8 var9 var10 706 - 707 - 708 -Example: 709 - 710 -* Example 1: Downlink Payload: AC 01 01 02 02 02 ~/~/ AT+DATACONV1=1,2+2,2 711 -* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02 ~/~/ AT+DATACONV2=1,2+2,2+3,2 712 - 713 - 714 - 715 - 716 - 717 717 **For example:** 718 718 719 719 This is my configuration: ... ... @@ -1416,11 +1416,7 @@ 1416 1416 1417 1417 **SDI-12-LB will uplink this payload.** 1418 1418 1419 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A ** 1420 -68253C5D 12 0C7801F10D302B312E31372B32372E340D0A 1421 -68253D33 12 0C7201F10D302B312E31352B32382E390D0A 1422 -68253DAB 12 0C7201F10D302B312E31342B32392E340D0A 1423 -68253E23 12 0C7201F10D302B312E31332B33302E300D0A 1383 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A 1424 1424 1425 1425 1426 1426 Where the first 23 bytes is for the first entry: