Last modified by Mengting Qiu on 2025/07/03 15:42

From version 166.2
edited by Mengting Qiu
on 2025/06/07 09:44
Change comment: There is no comment for this version
To version 165.1
edited by Mengting Qiu
on 2025/06/05 09:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -513,8 +513,6 @@
513 513  
514 514  (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
515 515  
516 -(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)**
517 -
518 518  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
519 519  
520 520  (% style="color:red" %)**0 **(%%) No validation check;
... ... @@ -679,41 +679,7 @@
679 679  
680 680  (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
681 681  
682 -* (% style="color:blue" %)**Downlink Command:**
683 683  
684 -Format: Command code (0xAC) followed by up to 20 bytes.
685 -
686 -
687 -Example 1 1:AT+DATACONVx=var1, var2   
688 -
689 -Downlink Command:AC x var1  var2
690 -
691 -Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 
692 -
693 -Downlink Command:AC x var1  var2  var3 var4
694 -
695 -Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6
696 -
697 -Downlink Command:AC x var1  var2  var3 var4 var5 var6
698 -
699 -Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8
700 -
701 -Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8
702 -
703 -Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10
704 -
705 -Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8 var9 var10
706 -
707 -
708 -Example:
709 -
710 -* Example 1: Downlink Payload: AC 01 01 02 02 02  ~/~/  AT+DATACONV1=1,2+2,2 
711 -* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02  ~/~/  AT+DATACONV2=1,2+2,2+3,2
712 -
713 -
714 -
715 -
716 -
717 717  **For example:**
718 718  
719 719  This is my configuration:
... ... @@ -1416,11 +1416,7 @@
1416 1416  
1417 1417  **SDI-12-LB will uplink this payload.**
1418 1418  
1419 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **
1420 -68253C5D 12 0C7801F10D302B312E31372B32372E340D0A
1421 -68253D33 12 0C7201F10D302B312E31352B32382E390D0A
1422 -68253DAB 12 0C7201F10D302B312E31342B32392E340D0A
1423 -68253E23 12 0C7201F10D302B312E31332B33302E300D0A
1383 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A
1424 1424  
1425 1425  
1426 1426  Where the first 23 bytes is for the first entry: