Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 166.2
edited by Mengting Qiu
on 2025/06/07 09:44
on 2025/06/07 09:44
Change comment:
There is no comment for this version
To version 156.1
edited by Mengting Qiu
on 2025/05/16 15:20
on 2025/05/16 15:20
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -513,8 +513,6 @@ 513 513 514 514 (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)** 515 515 516 -(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)** 517 - 518 518 (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries. 519 519 520 520 (% style="color:red" %)**0 **(%%) No validation check; ... ... @@ -679,46 +679,12 @@ 679 679 680 680 (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.** 681 681 682 -* (% style="color:blue" %)**Downlink Command:** 683 683 684 -Format: Command code (0xAC) followed by up to 20 bytes. 685 - 686 - 687 -Example 1 1:AT+DATACONVx=var1, var2 688 - 689 -Downlink Command:AC x var1 var2 690 - 691 -Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 692 - 693 -Downlink Command:AC x var1 var2 var3 var4 694 - 695 -Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6 696 - 697 -Downlink Command:AC x var1 var2 var3 var4 var5 var6 698 - 699 -Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8 700 - 701 -Downlink Command:AC x var1 var2 var3 var4 var5 var6 var7 var8 702 - 703 -Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10 704 - 705 -Downlink Command:AC x var1 var2 var3 var4 var5 var6 var7 var8 var9 var10 706 - 707 - 708 -Example: 709 - 710 -* Example 1: Downlink Payload: AC 01 01 02 02 02 ~/~/ AT+DATACONV1=1,2+2,2 711 -* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02 ~/~/ AT+DATACONV2=1,2+2,2+3,2 712 - 713 - 714 - 715 - 716 - 717 717 **For example:** 718 718 719 719 This is my configuration: 720 720 721 -[[image:image-20250 605091006-1.png]]685 +[[image:image-20250516103205-2.png]] 722 722 723 723 724 724 * AT+COMMAND1=0C!,0,2,0 After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately. ... ... @@ -1416,11 +1416,7 @@ 1416 1416 1417 1417 **SDI-12-LB will uplink this payload.** 1418 1418 1419 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A ** 1420 -68253C5D 12 0C7801F10D302B312E31372B32372E340D0A 1421 -68253D33 12 0C7201F10D302B312E31352B32382E390D0A 1422 -68253DAB 12 0C7201F10D302B312E31342B32392E340D0A 1423 -68253E23 12 0C7201F10D302B312E31332B33302E300D0A 1383 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A 1424 1424 1425 1425 1426 1426 Where the first 23 bytes is for the first entry: ... ... @@ -1674,7 +1674,7 @@ 1674 1674 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1675 1675 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1676 1676 1677 -== 3.7 Print data entries base on page(Since v1.3.0) == 1637 +=== 3.7 Print data entries base on page(Since v1.3.0) === 1678 1678 1679 1679 1680 1680 Feature: Print the sector data from start page to stop page (max is 416 pages). ... ... @@ -1718,7 +1718,7 @@ 1718 1718 No downlink commands for feature 1719 1719 1720 1720 1721 -== 3.8 Print last few data entries(Since v1.3.0) == 1681 +=== 3.8 Print last few data entries(Since v1.3.0) === 1722 1722 1723 1723 1724 1724 Feature: Print the last few data entries ... ... @@ -1730,7 +1730,7 @@ 1730 1730 |(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,0|(% style="background-color:#f2f2f2; width:192px" %)Printing the last ten data in hex format 1731 1731 |(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,1|(% style="background-color:#f2f2f2; width:192px" %)Print the last ten data in string format 1732 1732 1733 -* **Prints in hex format:**1693 +* Prints in hex format: 1734 1734 1735 1735 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1736 1736 |(% style="background-color:#4f81bd; color:white; width:158px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:352px" %)**Function** ... ... @@ -1828,6 +1828,7 @@ 1828 1828 1829 1829 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1830 1830 1791 + 1831 1831 == 3.10 SDI12 timing(Since v1.3.0) == 1832 1832 1833 1833 ... ... @@ -1835,7 +1835,6 @@ 1835 1835 1836 1836 [[image:1747289896656-580.png||height="414" width="566"]] 1837 1837 1838 - 1839 1839 (% style="color:#4f81bd" %)**AT Command: AT+SDITIMING** 1840 1840 1841 1841 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %) ... ... @@ -1854,101 +1854,6 @@ 1854 1854 1855 1855 * Example: 0xA90D09 ~/~/ Same as AT+SDITIMING=13,9 1856 1856 1857 -== 3.11 add Pulse_count, VDC_input, IDC_input(Since firmware V1.3.0) == 1858 - 1859 - 1860 -(% style="color:blue" %)**Setting up external sensors:** 1861 - 1862 -* (% style="color:#037691" %)**AT Command:** 1863 - 1864 -(% style="color:#4472c4" %)**AT+EXT=a,b,c**(%%) 1865 - 1866 -(% style="color:#4472c4" %)**a:**(%%) **0:** Disable Counting function ( doesn't effect interrupt ). **1:** Enable Counting function(4 bytes). 1867 -(% style="color:#4472c4" %)**b: **(%%) **0:** Disable voltage acquisition function. **1:** Enable voltage acquisition function(2 bytes) 1868 -(% style="color:#4472c4" %)**c:**(%%) **0:** Disable current acquisition function. **1:** Enable current acquisition function(2 bytes). 1869 - 1870 -**Example:** 1871 - 1872 -(% style="color:#4472c4" %)**AT+EXT=1,1,1** 1873 - 1874 -Device will add counting, voltage and current acquisition function. 1875 - 1876 -The payload will be: 1877 -Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting + ** ***VDC_INPUT** + ***IDC_INPUT** + Length depends on the return from the commands 1878 - 1879 -(% style="color:#4472c4" %)**AT+EXT=1,0,0** 1880 - 1881 -Device will add counting support. 1882 - 1883 -The payload will be: 1884 -Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting** + Length depends on the return from the commands 1885 - 1886 -* (% style="color:#037691" %)**Downlink Command: 0x0B aa bb cc** 1887 - 1888 -Format: Command Code (0x0B) followed by 3 bytes. 1889 - 1890 -(% style="color:#037691" %)**aa:**(%%) Set Disable or Enable Counting Support. **00**: Disable, **01**: Enable. 1891 - 1892 -(% style="color:#037691" %)**bb:**(%%) Set Disable or Enable voltage acquisition. **00**: Disable, **01**: Enable. 1893 - 1894 -(% style="color:#037691" %)**cc:**(%%) Set Disable or Enable current acquisition. **00**: Disable, **01**: Enable. 1895 - 1896 -**Example:** 1897 - 1898 -Downlink payload: 0B 00 00 01 ~/~/AT+EXT=0,0,1 Enable current acquisition 1899 - 1900 -Downlink payload: 0B 01 00 01 ~/~/AT+EXT=1,0,1 Enable Counting Support and Current acquisition 1901 - 1902 - 1903 -(% style="color:blue" %)**Set the pulse count value:** 1904 - 1905 -* (% style="color:#037691" %)**AT Command:** 1906 - 1907 -(% style="color:#4472c4" %)**AT+SETCNT=aa **(%%)~/~/ Set the pulse count value. 1908 - 1909 -**Example:** 1910 - 1911 -AT+SETCNT=100 (% style="display:none" %) (%%)~/~/ Set the pulse count to 100.(% style="display:none" %) 1912 - 1913 -* (% style="color:#037691" %)**Downlink Command: 0x0C** 1914 - 1915 -Format: Command Code (0x0C) followed by 4 bytes. 1916 - 1917 -**Example:** 1918 - 1919 -Downlink Payload: 0C 00 00 00 64 ~/~/ AT+SETCNT=100 1920 - 1921 - 1922 -(% style="color:blue" %)**Connect counting sensor:** 1923 - 1924 -The counting sensor cables are connected to the **3V3 pin** and **GPIO_EXTI** pin of the **SIB v1.3** motherboard. 1925 - 1926 -[[image:image-20250519110640-1.jpeg||height="318" width="708"]] 1927 - 1928 - 1929 -(% id="cke_bm_1699404S" style="color:blue; display:none" %)** **(% style="color:blue" %)**Connect Voltage output sensor:** 1930 - 1931 -Example: 1932 - 1933 -**RED <~-~-~-~-> VDC_INPUT** 1934 - 1935 -**BLACK <~-~-~-~-~-~-> GND** 1936 - 1937 -[[image:image-20250519111415-3.jpeg||height="338" width="710"]] 1938 - 1939 - 1940 -(% style="color:blue" %)**Connect Current output sensor:** 1941 - 1942 -Example: 1943 - 1944 -**RED <~-~-~-~-~-~-~-~--> IDC_INPUT** 1945 - 1946 -**BLACK <~-~-~-~-~-~-> GND** 1947 - 1948 -[[image:image-20250519111732-4.jpeg||height="373" width="708"]] 1949 - 1950 - 1951 - 1952 1952 = 4. Battery & Power Consumption = 1953 1953 1954 1954
- image-20250519110640-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -230.2 KB - Content
- image-20250519111322-2.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -228.0 KB - Content
- image-20250519111415-3.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -192.7 KB - Content
- image-20250519111732-4.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -193.7 KB - Content
- image-20250605091006-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -37.1 KB - Content