Last modified by Mengting Qiu on 2025/07/03 15:42

From version 164.1
edited by Mengting Qiu
on 2025/06/05 09:10
Change comment: Uploaded new attachment "image-20250605091006-1.png", version {1}
To version 167.1
edited by Mengting Qiu
on 2025/06/09 10:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -513,6 +513,8 @@
513 513  
514 514  (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
515 515  
516 +(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)**
517 +
516 516  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
517 517  
518 518  (% style="color:red" %)**0 **(%%) No validation check;
... ... @@ -677,12 +677,45 @@
677 677  
678 678  (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
679 679  
682 +* (% style="color:blue" %)**Downlink Command:**
680 680  
684 +Format: Command code (0xAC) followed by up to 20 bytes.
685 +
686 +
687 +Example 1 1:AT+DATACONVx=var1, var2   
688 +
689 +Downlink Command:AC x var1  var2
690 +
691 +Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 
692 +
693 +Downlink Command:AC x var1  var2  var3 var4
694 +
695 +Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6
696 +
697 +Downlink Command:AC x var1  var2  var3 var4 var5 var6
698 +
699 +Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8
700 +
701 +Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8
702 +
703 +Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10
704 +
705 +Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8 var9 var10
706 +
707 +
708 +Example:
709 +
710 +* Example 1: Downlink Payload: AC 01 01 02 02 02  ~/~/  AT+DATACONV1=1,2+2,2 
711 +* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02  ~/~/  AT+DATACONV2=1,2+2,2+3,2
712 +
713 +
714 +
715 +
681 681  **For example:**
682 682  
683 683  This is my configuration:
684 684  
685 -[[image:image-20250516103205-2.png]]
720 +[[image:image-20250605091006-1.png]]
686 686  
687 687  
688 688  * AT+COMMAND1=0C!,0,2,0  After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately.
... ... @@ -1380,7 +1380,11 @@
1380 1380  
1381 1381  **SDI-12-LB will uplink this payload.**
1382 1382  
1383 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A
1418 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **
1419 +68253C5D 12 0C7801F10D302B312E31372B32372E340D0A
1420 +68253D33 12 0C7201F10D302B312E31352B32382E390D0A
1421 +68253DAB 12 0C7201F10D302B312E31342B32392E340D0A
1422 +68253E23 12 0C7201F10D302B312E31332B33302E300D0A
1384 1384  
1385 1385  
1386 1386  Where the first 23 bytes is for the first entry:
... ... @@ -1634,7 +1634,6 @@
1634 1634  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1635 1635  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1636 1636  
1637 -
1638 1638  == 3.7 Print data entries base on page(Since v1.3.0) ==
1639 1639  
1640 1640  
... ... @@ -1770,7 +1770,7 @@
1770 1770  No downlink commands for feature
1771 1771  
1772 1772  
1773 -=== 3.9 Clear Flash Record(Since v1.3.0) ===
1811 +== 3.9 Clear Flash Record(Since v1.3.0) ==
1774 1774  
1775 1775  
1776 1776  Feature: Clear flash storage for data log feature.