Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 163.1
edited by Mengting Qiu
on 2025/05/19 11:22
on 2025/05/19 11:22
Change comment:
There is no comment for this version
To version 168.1
edited by Mengting Qiu
on 2025/06/09 10:32
on 2025/06/09 10:32
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -511,8 +511,10 @@ 511 511 512 512 (% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second) 513 513 514 -(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: Thereturneddatawill not be clipped.(since v1.3.0)**514 +(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.(since v1.3.0)** 515 515 516 +(% style="color:red" %)**(Function set to 2: When the device is connected to more than two sensors with different sampling addresses, concurrent measurement can be used to reduce data acquisition time and save battery power; for example, when the device is connected to two sensors with different addresses, the concurrent measurement function can be used and the two sensors can collect data at the same time.)** 517 + 516 516 (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries. 517 517 518 518 (% style="color:red" %)**0 **(%%) No validation check; ... ... @@ -677,12 +677,44 @@ 677 677 678 678 (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.** 679 679 682 +* (% style="color:blue" %)**Downlink Command:** 680 680 684 +Format: Command code (0xAC) followed by up to 20 bytes. 685 + 686 + 687 +Example 1 1:AT+DATACONVx=var1, var2 688 + 689 +Downlink Command:AC x var1 var2 690 + 691 +Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 692 + 693 +Downlink Command:AC x var1 var2 var3 var4 694 + 695 +Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6 696 + 697 +Downlink Command:AC x var1 var2 var3 var4 var5 var6 698 + 699 +Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8 700 + 701 +Downlink Command:AC x var1 var2 var3 var4 var5 var6 var7 var8 702 + 703 +Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10 704 + 705 +Downlink Command:AC x var1 var2 var3 var4 var5 var6 var7 var8 var9 var10 706 + 707 + 708 +Example: 709 + 710 +* Example 1: Downlink Payload: AC 01 01 02 02 02 ~/~/ AT+DATACONV1=1,2+2,2 711 +* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02 ~/~/ AT+DATACONV2=1,2+2,2+3,2 712 + 713 + 714 + 681 681 **For example:** 682 682 683 683 This is my configuration: 684 684 685 -[[image:image-2025051 6103205-2.png]]719 +[[image:image-20250605091006-1.png]] 686 686 687 687 688 688 * AT+COMMAND1=0C!,0,2,0 After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately. ... ... @@ -1380,7 +1380,11 @@ 1380 1380 1381 1381 **SDI-12-LB will uplink this payload.** 1382 1382 1383 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A 1417 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A ** 1418 +68253C5D 12 0C7801F10D302B312E31372B32372E340D0A 1419 +68253D33 12 0C7201F10D302B312E31352B32382E390D0A 1420 +68253DAB 12 0C7201F10D302B312E31342B32392E340D0A 1421 +68253E23 12 0C7201F10D302B312E31332B33302E300D0A 1384 1384 1385 1385 1386 1386 Where the first 23 bytes is for the first entry: ... ... @@ -1634,7 +1634,6 @@ 1634 1634 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1635 1635 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1636 1636 1637 - 1638 1638 == 3.7 Print data entries base on page(Since v1.3.0) == 1639 1639 1640 1640 ... ... @@ -1770,7 +1770,7 @@ 1770 1770 No downlink commands for feature 1771 1771 1772 1772 1773 -== =3.9 Clear Flash Record(Since v1.3.0) ===1810 +== 3.9 Clear Flash Record(Since v1.3.0) == 1774 1774 1775 1775 1776 1776 Feature: Clear flash storage for data log feature.
- image-20250605091006-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.1 KB - Content