Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 157.1
edited by Mengting Qiu
on 2025/05/16 17:07
on 2025/05/16 17:07
Change comment:
There is no comment for this version
To version 166.2
edited by Mengting Qiu
on 2025/06/07 09:44
on 2025/06/07 09:44
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -513,6 +513,8 @@ 513 513 514 514 (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)** 515 515 516 +(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)** 517 + 516 516 (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries. 517 517 518 518 (% style="color:red" %)**0 **(%%) No validation check; ... ... @@ -677,12 +677,46 @@ 677 677 678 678 (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.** 679 679 682 +* (% style="color:blue" %)**Downlink Command:** 680 680 684 +Format: Command code (0xAC) followed by up to 20 bytes. 685 + 686 + 687 +Example 1 1:AT+DATACONVx=var1, var2 688 + 689 +Downlink Command:AC x var1 var2 690 + 691 +Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 692 + 693 +Downlink Command:AC x var1 var2 var3 var4 694 + 695 +Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6 696 + 697 +Downlink Command:AC x var1 var2 var3 var4 var5 var6 698 + 699 +Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8 700 + 701 +Downlink Command:AC x var1 var2 var3 var4 var5 var6 var7 var8 702 + 703 +Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10 704 + 705 +Downlink Command:AC x var1 var2 var3 var4 var5 var6 var7 var8 var9 var10 706 + 707 + 708 +Example: 709 + 710 +* Example 1: Downlink Payload: AC 01 01 02 02 02 ~/~/ AT+DATACONV1=1,2+2,2 711 +* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02 ~/~/ AT+DATACONV2=1,2+2,2+3,2 712 + 713 + 714 + 715 + 716 + 681 681 **For example:** 682 682 683 683 This is my configuration: 684 684 685 -[[image:image-2025051 6103205-2.png]]721 +[[image:image-20250605091006-1.png]] 686 686 687 687 688 688 * AT+COMMAND1=0C!,0,2,0 After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately. ... ... @@ -1380,7 +1380,11 @@ 1380 1380 1381 1381 **SDI-12-LB will uplink this payload.** 1382 1382 1383 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A 1419 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A ** 1420 +68253C5D 12 0C7801F10D302B312E31372B32372E340D0A 1421 +68253D33 12 0C7201F10D302B312E31352B32382E390D0A 1422 +68253DAB 12 0C7201F10D302B312E31342B32392E340D0A 1423 +68253E23 12 0C7201F10D302B312E31332B33302E300D0A 1384 1384 1385 1385 1386 1386 Where the first 23 bytes is for the first entry: ... ... @@ -1634,7 +1634,7 @@ 1634 1634 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1635 1635 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1636 1636 1637 -== =3.7 Print data entries base on page(Since v1.3.0) ===1677 +== 3.7 Print data entries base on page(Since v1.3.0) == 1638 1638 1639 1639 1640 1640 Feature: Print the sector data from start page to stop page (max is 416 pages). ... ... @@ -1678,7 +1678,7 @@ 1678 1678 No downlink commands for feature 1679 1679 1680 1680 1681 -== =3.8 Print last few data entries(Since v1.3.0) ===1721 +== 3.8 Print last few data entries(Since v1.3.0) == 1682 1682 1683 1683 1684 1684 Feature: Print the last few data entries ... ... @@ -1690,7 +1690,7 @@ 1690 1690 |(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,0|(% style="background-color:#f2f2f2; width:192px" %)Printing the last ten data in hex format 1691 1691 |(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,1|(% style="background-color:#f2f2f2; width:192px" %)Print the last ten data in string format 1692 1692 1693 -* Prints in hex format: 1733 +* **Prints in hex format:** 1694 1694 1695 1695 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1696 1696 |(% style="background-color:#4f81bd; color:white; width:158px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:352px" %)**Function** ... ... @@ -1788,8 +1788,6 @@ 1788 1788 1789 1789 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1790 1790 1791 - 1792 - 1793 1793 == 3.10 SDI12 timing(Since v1.3.0) == 1794 1794 1795 1795 ... ... @@ -1816,8 +1816,6 @@ 1816 1816 1817 1817 * Example: 0xA90D09 ~/~/ Same as AT+SDITIMING=13,9 1818 1818 1819 - 1820 - 1821 1821 == 3.11 add Pulse_count, VDC_input, IDC_input(Since firmware V1.3.0) == 1822 1822 1823 1823 ... ... @@ -1887,10 +1887,10 @@ 1887 1887 1888 1888 The counting sensor cables are connected to the **3V3 pin** and **GPIO_EXTI** pin of the **SIB v1.3** motherboard. 1889 1889 1890 -[[image:image-202 41223102347-4.jpeg||height="437" width="683"]]1926 +[[image:image-20250519110640-1.jpeg||height="318" width="708"]] 1891 1891 1892 1892 1893 -(% id="cke_bm_1699404S" style="color: 1929 +(% id="cke_bm_1699404S" style="color:blue; display:none" %)** **(% style="color:blue" %)**Connect Voltage output sensor:** 1894 1894 1895 1895 Example: 1896 1896 ... ... @@ -1898,7 +1898,7 @@ 1898 1898 1899 1899 **BLACK <~-~-~-~-~-~-> GND** 1900 1900 1901 -[[image:image-202 41223101841-3.jpeg||height="417" width="666"]]1937 +[[image:image-20250519111415-3.jpeg||height="338" width="710"]] 1902 1902 1903 1903 1904 1904 (% style="color:blue" %)**Connect Current output sensor:** ... ... @@ -1909,11 +1909,10 @@ 1909 1909 1910 1910 **BLACK <~-~-~-~-~-~-> GND** 1911 1911 1912 -[[image:image-202 41223100438-2.jpeg||height="440" width="672"]]1948 +[[image:image-20250519111732-4.jpeg||height="373" width="708"]] 1913 1913 1914 1914 1915 1915 1916 - 1917 1917 = 4. Battery & Power Consumption = 1918 1918 1919 1919
- image-20250519110640-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +230.2 KB - Content
- image-20250519111322-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +228.0 KB - Content
- image-20250519111415-3.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +192.7 KB - Content
- image-20250519111732-4.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +193.7 KB - Content
- image-20250605091006-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.1 KB - Content