Last modified by Mengting Qiu on 2025/07/03 15:42

From version 157.1
edited by Mengting Qiu
on 2025/05/16 17:07
Change comment: There is no comment for this version
To version 166.2
edited by Mengting Qiu
on 2025/06/07 09:44
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -513,6 +513,8 @@
513 513  
514 514  (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
515 515  
516 +(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)**
517 +
516 516  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
517 517  
518 518  (% style="color:red" %)**0 **(%%) No validation check;
... ... @@ -677,12 +677,46 @@
677 677  
678 678  (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
679 679  
682 +* (% style="color:blue" %)**Downlink Command:**
680 680  
684 +Format: Command code (0xAC) followed by up to 20 bytes.
685 +
686 +
687 +Example 1 1:AT+DATACONVx=var1, var2   
688 +
689 +Downlink Command:AC x var1  var2
690 +
691 +Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 
692 +
693 +Downlink Command:AC x var1  var2  var3 var4
694 +
695 +Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6
696 +
697 +Downlink Command:AC x var1  var2  var3 var4 var5 var6
698 +
699 +Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8
700 +
701 +Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8
702 +
703 +Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10
704 +
705 +Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8 var9 var10
706 +
707 +
708 +Example:
709 +
710 +* Example 1: Downlink Payload: AC 01 01 02 02 02  ~/~/  AT+DATACONV1=1,2+2,2 
711 +* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02  ~/~/  AT+DATACONV2=1,2+2,2+3,2
712 +
713 +
714 +
715 +
716 +
681 681  **For example:**
682 682  
683 683  This is my configuration:
684 684  
685 -[[image:image-20250516103205-2.png]]
721 +[[image:image-20250605091006-1.png]]
686 686  
687 687  
688 688  * AT+COMMAND1=0C!,0,2,0  After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately.
... ... @@ -1380,7 +1380,11 @@
1380 1380  
1381 1381  **SDI-12-LB will uplink this payload.**
1382 1382  
1383 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A
1419 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **
1420 +68253C5D 12 0C7801F10D302B312E31372B32372E340D0A
1421 +68253D33 12 0C7201F10D302B312E31352B32382E390D0A
1422 +68253DAB 12 0C7201F10D302B312E31342B32392E340D0A
1423 +68253E23 12 0C7201F10D302B312E31332B33302E300D0A
1384 1384  
1385 1385  
1386 1386  Where the first 23 bytes is for the first entry:
... ... @@ -1634,7 +1634,7 @@
1634 1634  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1635 1635  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1636 1636  
1637 -=== 3.7 Print data entries base on page(Since v1.3.0) ===
1677 +== 3.7 Print data entries base on page(Since v1.3.0) ==
1638 1638  
1639 1639  
1640 1640  Feature: Print the sector data from start page to stop page (max is 416 pages).
... ... @@ -1678,7 +1678,7 @@
1678 1678  No downlink commands for feature
1679 1679  
1680 1680  
1681 -=== 3.8 Print last few data entries(Since v1.3.0) ===
1721 +== 3.8 Print last few data entries(Since v1.3.0) ==
1682 1682  
1683 1683  
1684 1684  Feature: Print the last few data entries
... ... @@ -1690,7 +1690,7 @@
1690 1690  |(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,0|(% style="background-color:#f2f2f2; width:192px" %)Printing the last ten data in hex format
1691 1691  |(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,1|(% style="background-color:#f2f2f2; width:192px" %)Print the last ten data in string format
1692 1692  
1693 -* Prints in hex format:
1733 +* **Prints in hex format:**
1694 1694  
1695 1695  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
1696 1696  |(% style="background-color:#4f81bd; color:white; width:158px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:352px" %)**Function**
... ... @@ -1788,8 +1788,6 @@
1788 1788  
1789 1789  * Example: 0xA301  ~/~/  Same as AT+CLRDTA
1790 1790  
1791 -
1792 -
1793 1793  == 3.10 SDI12 timing(Since v1.3.0) ==
1794 1794  
1795 1795  
... ... @@ -1816,8 +1816,6 @@
1816 1816  
1817 1817  * Example: 0xA90D09  ~/~/  Same as AT+SDITIMING=13,9
1818 1818  
1819 -
1820 -
1821 1821  == 3.11 add Pulse_count, VDC_input, IDC_input(Since firmware V1.3.0) ==
1822 1822  
1823 1823  
... ... @@ -1887,10 +1887,10 @@
1887 1887  
1888 1888  The counting sensor cables are connected to the **3V3 pin** and **GPIO_EXTI** pin of the **SIB v1.3** motherboard.
1889 1889  
1890 -[[image:image-20241223102347-4.jpeg||height="437" width="683"]]
1926 +[[image:image-20250519110640-1.jpeg||height="318" width="708"]]
1891 1891  
1892 1892  
1893 -(% id="cke_bm_1699404S" style="color: blue; display: none" %)** **(% style="color:blue" %)**Connect Voltage output sensor:**
1929 +(% id="cke_bm_1699404S" style="color:blue; display:none" %)** **(% style="color:blue" %)**Connect Voltage output sensor:**
1894 1894  
1895 1895  Example:
1896 1896  
... ... @@ -1898,7 +1898,7 @@
1898 1898  
1899 1899  **BLACK <~-~-~-~-~-~-> GND**
1900 1900  
1901 -[[image:image-20241223101841-3.jpeg||height="417" width="666"]]
1937 +[[image:image-20250519111415-3.jpeg||height="338" width="710"]]
1902 1902  
1903 1903  
1904 1904  (% style="color:blue" %)**Connect Current output sensor:**
... ... @@ -1909,11 +1909,10 @@
1909 1909  
1910 1910  **BLACK <~-~-~-~-~-~-> GND**
1911 1911  
1912 -[[image:image-20241223100438-2.jpeg||height="440" width="672"]]
1948 +[[image:image-20250519111732-4.jpeg||height="373" width="708"]]
1913 1913  
1914 1914  
1915 1915  
1916 -
1917 1917  = 4. Battery & Power Consumption =
1918 1918  
1919 1919  
image-20250519110640-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +230.2 KB
Content
image-20250519111322-2.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +228.0 KB
Content
image-20250519111415-3.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +192.7 KB
Content
image-20250519111732-4.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +193.7 KB
Content
image-20250605091006-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +37.1 KB
Content