Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 157.1
edited by Mengting Qiu
on 2025/05/16 17:07
on 2025/05/16 17:07
Change comment:
There is no comment for this version
To version 156.1
edited by Mengting Qiu
on 2025/05/16 15:20
on 2025/05/16 15:20
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1789,7 +1789,6 @@ 1789 1789 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1790 1790 1791 1791 1792 - 1793 1793 == 3.10 SDI12 timing(Since v1.3.0) == 1794 1794 1795 1795 ... ... @@ -1797,7 +1797,6 @@ 1797 1797 1798 1798 [[image:1747289896656-580.png||height="414" width="566"]] 1799 1799 1800 - 1801 1801 (% style="color:#4f81bd" %)**AT Command: AT+SDITIMING** 1802 1802 1803 1803 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %) ... ... @@ -1816,104 +1816,6 @@ 1816 1816 1817 1817 * Example: 0xA90D09 ~/~/ Same as AT+SDITIMING=13,9 1818 1818 1819 - 1820 - 1821 -== 3.11 add Pulse_count, VDC_input, IDC_input(Since firmware V1.3.0) == 1822 - 1823 - 1824 -(% style="color:blue" %)**Setting up external sensors:** 1825 - 1826 -* (% style="color:#037691" %)**AT Command:** 1827 - 1828 -(% style="color:#4472c4" %)**AT+EXT=a,b,c**(%%) 1829 - 1830 -(% style="color:#4472c4" %)**a:**(%%) **0:** Disable Counting function ( doesn't effect interrupt ). **1:** Enable Counting function(4 bytes). 1831 -(% style="color:#4472c4" %)**b: **(%%) **0:** Disable voltage acquisition function. **1:** Enable voltage acquisition function(2 bytes) 1832 -(% style="color:#4472c4" %)**c:**(%%) **0:** Disable current acquisition function. **1:** Enable current acquisition function(2 bytes). 1833 - 1834 -**Example:** 1835 - 1836 -(% style="color:#4472c4" %)**AT+EXT=1,1,1** 1837 - 1838 -Device will add counting, voltage and current acquisition function. 1839 - 1840 -The payload will be: 1841 -Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting + ** ***VDC_INPUT** + ***IDC_INPUT** + Length depends on the return from the commands 1842 - 1843 -(% style="color:#4472c4" %)**AT+EXT=1,0,0** 1844 - 1845 -Device will add counting support. 1846 - 1847 -The payload will be: 1848 -Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting** + Length depends on the return from the commands 1849 - 1850 -* (% style="color:#037691" %)**Downlink Command: 0x0B aa bb cc** 1851 - 1852 -Format: Command Code (0x0B) followed by 3 bytes. 1853 - 1854 -(% style="color:#037691" %)**aa:**(%%) Set Disable or Enable Counting Support. **00**: Disable, **01**: Enable. 1855 - 1856 -(% style="color:#037691" %)**bb:**(%%) Set Disable or Enable voltage acquisition. **00**: Disable, **01**: Enable. 1857 - 1858 -(% style="color:#037691" %)**cc:**(%%) Set Disable or Enable current acquisition. **00**: Disable, **01**: Enable. 1859 - 1860 -**Example:** 1861 - 1862 -Downlink payload: 0B 00 00 01 ~/~/AT+EXT=0,0,1 Enable current acquisition 1863 - 1864 -Downlink payload: 0B 01 00 01 ~/~/AT+EXT=1,0,1 Enable Counting Support and Current acquisition 1865 - 1866 - 1867 -(% style="color:blue" %)**Set the pulse count value:** 1868 - 1869 -* (% style="color:#037691" %)**AT Command:** 1870 - 1871 -(% style="color:#4472c4" %)**AT+SETCNT=aa **(%%)~/~/ Set the pulse count value. 1872 - 1873 -**Example:** 1874 - 1875 -AT+SETCNT=100 (% style="display:none" %) (%%)~/~/ Set the pulse count to 100.(% style="display:none" %) 1876 - 1877 -* (% style="color:#037691" %)**Downlink Command: 0x0C** 1878 - 1879 -Format: Command Code (0x0C) followed by 4 bytes. 1880 - 1881 -**Example:** 1882 - 1883 -Downlink Payload: 0C 00 00 00 64 ~/~/ AT+SETCNT=100 1884 - 1885 - 1886 -(% style="color:blue" %)**Connect counting sensor:** 1887 - 1888 -The counting sensor cables are connected to the **3V3 pin** and **GPIO_EXTI** pin of the **SIB v1.3** motherboard. 1889 - 1890 -[[image:image-20241223102347-4.jpeg||height="437" width="683"]] 1891 - 1892 - 1893 -(% id="cke_bm_1699404S" style="color: blue; display: none" %)** **(% style="color:blue" %)**Connect Voltage output sensor:** 1894 - 1895 -Example: 1896 - 1897 -**RED <~-~-~-~-> VDC_INPUT** 1898 - 1899 -**BLACK <~-~-~-~-~-~-> GND** 1900 - 1901 -[[image:image-20241223101841-3.jpeg||height="417" width="666"]] 1902 - 1903 - 1904 -(% style="color:blue" %)**Connect Current output sensor:** 1905 - 1906 -Example: 1907 - 1908 -**RED <~-~-~-~-~-~-~-~--> IDC_INPUT** 1909 - 1910 -**BLACK <~-~-~-~-~-~-> GND** 1911 - 1912 -[[image:image-20241223100438-2.jpeg||height="440" width="672"]] 1913 - 1914 - 1915 - 1916 - 1917 1917 = 4. Battery & Power Consumption = 1918 1918 1919 1919