Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 155.3
edited by Mengting Qiu
on 2025/05/16 15:14
on 2025/05/16 15:14
Change comment:
There is no comment for this version
To version 157.1
edited by Mengting Qiu
on 2025/05/16 17:07
on 2025/05/16 17:07
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1789,6 +1789,7 @@ 1789 1789 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1790 1790 1791 1791 1792 + 1792 1792 == 3.10 SDI12 timing(Since v1.3.0) == 1793 1793 1794 1794 ... ... @@ -1796,6 +1796,7 @@ 1796 1796 1797 1797 [[image:1747289896656-580.png||height="414" width="566"]] 1798 1798 1800 + 1799 1799 (% style="color:#4f81bd" %)**AT Command: AT+SDITIMING** 1800 1800 1801 1801 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %) ... ... @@ -1814,6 +1814,104 @@ 1814 1814 1815 1815 * Example: 0xA90D09 ~/~/ Same as AT+SDITIMING=13,9 1816 1816 1819 + 1820 + 1821 +== 3.11 add Pulse_count, VDC_input, IDC_input(Since firmware V1.3.0) == 1822 + 1823 + 1824 +(% style="color:blue" %)**Setting up external sensors:** 1825 + 1826 +* (% style="color:#037691" %)**AT Command:** 1827 + 1828 +(% style="color:#4472c4" %)**AT+EXT=a,b,c**(%%) 1829 + 1830 +(% style="color:#4472c4" %)**a:**(%%) **0:** Disable Counting function ( doesn't effect interrupt ). **1:** Enable Counting function(4 bytes). 1831 +(% style="color:#4472c4" %)**b: **(%%) **0:** Disable voltage acquisition function. **1:** Enable voltage acquisition function(2 bytes) 1832 +(% style="color:#4472c4" %)**c:**(%%) **0:** Disable current acquisition function. **1:** Enable current acquisition function(2 bytes). 1833 + 1834 +**Example:** 1835 + 1836 +(% style="color:#4472c4" %)**AT+EXT=1,1,1** 1837 + 1838 +Device will add counting, voltage and current acquisition function. 1839 + 1840 +The payload will be: 1841 +Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting + ** ***VDC_INPUT** + ***IDC_INPUT** + Length depends on the return from the commands 1842 + 1843 +(% style="color:#4472c4" %)**AT+EXT=1,0,0** 1844 + 1845 +Device will add counting support. 1846 + 1847 +The payload will be: 1848 +Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting** + Length depends on the return from the commands 1849 + 1850 +* (% style="color:#037691" %)**Downlink Command: 0x0B aa bb cc** 1851 + 1852 +Format: Command Code (0x0B) followed by 3 bytes. 1853 + 1854 +(% style="color:#037691" %)**aa:**(%%) Set Disable or Enable Counting Support. **00**: Disable, **01**: Enable. 1855 + 1856 +(% style="color:#037691" %)**bb:**(%%) Set Disable or Enable voltage acquisition. **00**: Disable, **01**: Enable. 1857 + 1858 +(% style="color:#037691" %)**cc:**(%%) Set Disable or Enable current acquisition. **00**: Disable, **01**: Enable. 1859 + 1860 +**Example:** 1861 + 1862 +Downlink payload: 0B 00 00 01 ~/~/AT+EXT=0,0,1 Enable current acquisition 1863 + 1864 +Downlink payload: 0B 01 00 01 ~/~/AT+EXT=1,0,1 Enable Counting Support and Current acquisition 1865 + 1866 + 1867 +(% style="color:blue" %)**Set the pulse count value:** 1868 + 1869 +* (% style="color:#037691" %)**AT Command:** 1870 + 1871 +(% style="color:#4472c4" %)**AT+SETCNT=aa **(%%)~/~/ Set the pulse count value. 1872 + 1873 +**Example:** 1874 + 1875 +AT+SETCNT=100 (% style="display:none" %) (%%)~/~/ Set the pulse count to 100.(% style="display:none" %) 1876 + 1877 +* (% style="color:#037691" %)**Downlink Command: 0x0C** 1878 + 1879 +Format: Command Code (0x0C) followed by 4 bytes. 1880 + 1881 +**Example:** 1882 + 1883 +Downlink Payload: 0C 00 00 00 64 ~/~/ AT+SETCNT=100 1884 + 1885 + 1886 +(% style="color:blue" %)**Connect counting sensor:** 1887 + 1888 +The counting sensor cables are connected to the **3V3 pin** and **GPIO_EXTI** pin of the **SIB v1.3** motherboard. 1889 + 1890 +[[image:image-20241223102347-4.jpeg||height="437" width="683"]] 1891 + 1892 + 1893 +(% id="cke_bm_1699404S" style="color: blue; display: none" %)** **(% style="color:blue" %)**Connect Voltage output sensor:** 1894 + 1895 +Example: 1896 + 1897 +**RED <~-~-~-~-> VDC_INPUT** 1898 + 1899 +**BLACK <~-~-~-~-~-~-> GND** 1900 + 1901 +[[image:image-20241223101841-3.jpeg||height="417" width="666"]] 1902 + 1903 + 1904 +(% style="color:blue" %)**Connect Current output sensor:** 1905 + 1906 +Example: 1907 + 1908 +**RED <~-~-~-~-~-~-~-~--> IDC_INPUT** 1909 + 1910 +**BLACK <~-~-~-~-~-~-> GND** 1911 + 1912 +[[image:image-20241223100438-2.jpeg||height="440" width="672"]] 1913 + 1914 + 1915 + 1916 + 1817 1817 = 4. Battery & Power Consumption = 1818 1818 1819 1819