Last modified by Mengting Qiu on 2025/07/03 15:42

From version 155.3
edited by Mengting Qiu
on 2025/05/16 15:14
Change comment: There is no comment for this version
To version 157.1
edited by Mengting Qiu
on 2025/05/16 17:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1789,6 +1789,7 @@
1789 1789  * Example: 0xA301  ~/~/  Same as AT+CLRDTA
1790 1790  
1791 1791  
1792 +
1792 1792  == 3.10 SDI12 timing(Since v1.3.0) ==
1793 1793  
1794 1794  
... ... @@ -1796,6 +1796,7 @@
1796 1796  
1797 1797  [[image:1747289896656-580.png||height="414" width="566"]]
1798 1798  
1800 +
1799 1799  (% style="color:#4f81bd" %)**AT Command: AT+SDITIMING**
1800 1800  
1801 1801  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %)
... ... @@ -1814,6 +1814,104 @@
1814 1814  
1815 1815  * Example: 0xA90D09  ~/~/  Same as AT+SDITIMING=13,9
1816 1816  
1819 +
1820 +
1821 +== 3.11 add Pulse_count, VDC_input, IDC_input(Since firmware V1.3.0) ==
1822 +
1823 +
1824 +(% style="color:blue" %)**Setting up external sensors:**
1825 +
1826 +* (% style="color:#037691" %)**AT Command:**
1827 +
1828 +(% style="color:#4472c4" %)**AT+EXT=a,b,c**(%%)
1829 +
1830 +(% style="color:#4472c4" %)**a:**(%%)  **0:** Disable Counting function ( doesn't effect interrupt ).  **1:** Enable Counting function(4 bytes).
1831 +(% style="color:#4472c4" %)**b: **(%%) **0:** Disable voltage acquisition function.  **1:** Enable voltage acquisition function(2 bytes)
1832 +(% style="color:#4472c4" %)**c:**(%%)  **0:** Disable current acquisition  function.  **1:** Enable current acquisition function(2 bytes).
1833 +
1834 +**Example:**
1835 +
1836 +(% style="color:#4472c4" %)**AT+EXT=1,1,1**
1837 +
1838 +Device will add counting, voltage and current acquisition function.
1839 +
1840 +The payload will be:
1841 +Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting + ** ***VDC_INPUT**  + ***IDC_INPUT**  + Length depends on the return from the commands
1842 +
1843 +(% style="color:#4472c4" %)**AT+EXT=1,0,0**
1844 +
1845 +Device will add counting support.
1846 +
1847 +The payload will be:
1848 +Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting** + Length depends on the return from the commands
1849 +
1850 +* (% style="color:#037691" %)**Downlink Command: 0x0B aa bb cc**
1851 +
1852 +Format: Command Code (0x0B) followed by 3 bytes.
1853 +
1854 +(% style="color:#037691" %)**aa:**(%%) Set Disable or Enable Counting Support.   **00**: Disable, **01**: Enable.
1855 +
1856 +(% style="color:#037691" %)**bb:**(%%) Set Disable or Enable voltage acquisition.  **00**: Disable, **01**: Enable.
1857 +
1858 +(% style="color:#037691" %)**cc:**(%%) Set Disable or Enable current acquisition.  **00**: Disable, **01**: Enable.
1859 +
1860 +**Example:**
1861 +
1862 +Downlink payload:  0B 00 00 01  ~/~/AT+EXT=0,0,1  Enable current acquisition
1863 +
1864 +Downlink payload:  0B 01 00 01  ~/~/AT+EXT=1,0,1  Enable Counting Support and Current acquisition                        
1865 +
1866 +
1867 +(% style="color:blue" %)**Set the pulse count value:**
1868 +
1869 +* (% style="color:#037691" %)**AT Command:**
1870 +
1871 +(% style="color:#4472c4" %)**AT+SETCNT=aa     **(%%)~/~/ Set the pulse count value.
1872 +
1873 +**Example:**
1874 +
1875 +AT+SETCNT=100  (% style="display:none" %) (%%)~/~/ Set the pulse count to 100.(% style="display:none" %)
1876 +
1877 +* (% style="color:#037691" %)**Downlink Command: 0x0C**
1878 +
1879 +Format: Command Code (0x0C) followed by 4 bytes.
1880 +
1881 +**Example:**
1882 +
1883 +Downlink Payload: 0C 00 00 00 64  ~/~/ AT+SETCNT=100
1884 +
1885 +
1886 +(% style="color:blue" %)**Connect counting sensor:**
1887 +
1888 +The counting sensor cables are connected to the **3V3 pin** and **GPIO_EXTI** pin of the **SIB v1.3** motherboard.
1889 +
1890 +[[image:image-20241223102347-4.jpeg||height="437" width="683"]]
1891 +
1892 +
1893 +(% id="cke_bm_1699404S" style="color: blue; display: none" %)** **(% style="color:blue" %)**Connect Voltage output sensor:**
1894 +
1895 +Example:
1896 +
1897 +**RED <~-~-~-~-> VDC_INPUT**
1898 +
1899 +**BLACK <~-~-~-~-~-~-> GND**
1900 +
1901 +[[image:image-20241223101841-3.jpeg||height="417" width="666"]]
1902 +
1903 +
1904 +(% style="color:blue" %)**Connect Current output sensor:**
1905 +
1906 +Example:
1907 +
1908 +**RED <~-~-~-~-~-~-~-~--> IDC_INPUT**
1909 +
1910 +**BLACK <~-~-~-~-~-~-> GND**
1911 +
1912 +[[image:image-20241223100438-2.jpeg||height="440" width="672"]]
1913 +
1914 +
1915 +
1916 +
1817 1817  = 4. Battery & Power Consumption =