Last modified by Mengting Qiu on 2025/07/03 15:42

From version 155.1
edited by Mengting Qiu
on 2025/05/16 14:54
Change comment: Uploaded new attachment "image-20250516145402-2.png", version {1}
To version 166.2
edited by Mengting Qiu
on 2025/06/07 09:44
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -513,6 +513,8 @@
513 513  
514 514  (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
515 515  
516 +(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)**
517 +
516 516  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
517 517  
518 518  (% style="color:red" %)**0 **(%%) No validation check;
... ... @@ -677,12 +677,46 @@
677 677  
678 678  (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
679 679  
682 +* (% style="color:blue" %)**Downlink Command:**
680 680  
684 +Format: Command code (0xAC) followed by up to 20 bytes.
685 +
686 +
687 +Example 1 1:AT+DATACONVx=var1, var2   
688 +
689 +Downlink Command:AC x var1  var2
690 +
691 +Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 
692 +
693 +Downlink Command:AC x var1  var2  var3 var4
694 +
695 +Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6
696 +
697 +Downlink Command:AC x var1  var2  var3 var4 var5 var6
698 +
699 +Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8
700 +
701 +Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8
702 +
703 +Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10
704 +
705 +Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8 var9 var10
706 +
707 +
708 +Example:
709 +
710 +* Example 1: Downlink Payload: AC 01 01 02 02 02  ~/~/  AT+DATACONV1=1,2+2,2 
711 +* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02  ~/~/  AT+DATACONV2=1,2+2,2+3,2
712 +
713 +
714 +
715 +
716 +
681 681  **For example:**
682 682  
683 683  This is my configuration:
684 684  
685 -[[image:image-20250516103205-2.png]]
721 +[[image:image-20250605091006-1.png]]
686 686  
687 687  
688 688  * AT+COMMAND1=0C!,0,2,0  After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately.
... ... @@ -691,16 +691,28 @@
691 691  
692 692  This is the data obtained:
693 693  
694 -[[image:image-20250516103652-3.png]]
730 +[[image:image-20250516145402-2.png]]
695 695  
696 696  
697 697  When using the AT+DATACONVx command,
698 698  
699 -The data of RETURN3 will be converted into 2 data, the first data is +101, and the second data is +263.
735 +The data of RETURN3 will be converted into 2 data, the first data is +95, and the second data is +260.
700 700  
701 701  * AT+DATACONV3=1,2+2,2  The first data is uploaded as 2 bytes and the second data is uploaded as 2 bytes. The form converted to hexadecimal is as shown above,as below:
702 702  
739 +[[image:image-20250516144559-1.png]]
703 703  
741 +0C90 01 005F 0104
742 +
743 +(% style="color:#037691" %)**BAT**(%%): 0x0c90 = 3216mV = 3.216V
744 +
745 +(% style="color:#037691" %)**Payload Version**(%%): 0x01, Means: v1.0 version
746 +
747 +(% style="color:#037691" %)**Data 1: **(%%)0x005F(H) = 95(D) / 100 = 0.95
748 +
749 +(% style="color:#037691" %)**Data 2: **(%%)0x0104(H) = 260(D) / 10 = 26.0
750 +
751 +
704 704  == 2.4 Uplink Payload ==
705 705  
706 706  === 2.4.1 Device Payload, FPORT~=5 ===
... ... @@ -1368,7 +1368,11 @@
1368 1368  
1369 1369  **SDI-12-LB will uplink this payload.**
1370 1370  
1371 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A
1419 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **
1420 +68253C5D 12 0C7801F10D302B312E31372B32372E340D0A
1421 +68253D33 12 0C7201F10D302B312E31352B32382E390D0A
1422 +68253DAB 12 0C7201F10D302B312E31342B32392E340D0A
1423 +68253E23 12 0C7201F10D302B312E31332B33302E300D0A
1372 1372  
1373 1373  
1374 1374  Where the first 23 bytes is for the first entry:
... ... @@ -1622,7 +1622,7 @@
1622 1622  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1623 1623  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1624 1624  
1625 -=== 3.7 Print data entries base on page(Since v1.3.0) ===
1677 +== 3.7 Print data entries base on page(Since v1.3.0) ==
1626 1626  
1627 1627  
1628 1628  Feature: Print the sector data from start page to stop page (max is 416 pages).
... ... @@ -1666,7 +1666,7 @@
1666 1666  No downlink commands for feature
1667 1667  
1668 1668  
1669 -=== 3.8 Print last few data entries(Since v1.3.0) ===
1721 +== 3.8 Print last few data entries(Since v1.3.0) ==
1670 1670  
1671 1671  
1672 1672  Feature: Print the last few data entries
... ... @@ -1673,29 +1673,85 @@
1673 1673  
1674 1674  (% style="color:#4f81bd" %)**AT Command: AT+PLDTA**
1675 1675  
1728 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:437px" %)
1729 +|=(% style="width: 158px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 192px;background-color:#4F81BD;color:white" %)**Function**
1730 +|(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,0|(% style="background-color:#f2f2f2; width:192px" %)Printing the last ten data in hex format
1731 +|(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,1|(% style="background-color:#f2f2f2; width:192px" %)Print the last ten data in string format
1732 +
1733 +* **Prints in hex format:**
1734 +
1676 1676  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
1677 1677  |(% style="background-color:#4f81bd; color:white; width:158px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:352px" %)**Function**
1678 1678  |(% style="width:156px" %)(((
1679 -AT+PLDTA=10
1738 +AT+PLDTA=10,0
1680 1680  Print last 10 entries
1681 1681  )))|(% style="width:311px" %)(((
1682 1682  Stop Tx events when read sensor data
1683 1683  
1684 -0001-0002 2025/5/15 01:04:43 18 0c 72 01 f1 0d 30 2b 31 2e 31 34 2b 32 39 2e 34 0d 0a
1743 +0001-0001 2025/5/16 06:48:04 7 0c 7e 01 00 5f 01 05
1685 1685  
1686 -0003-0004 2025/5/15 01:06:43 18 0c 72 01 f1 0d 30 2b 31 2e 31 33 2b 33 30 2e 30 0d 0a
1745 +0002-0002 2025/5/16 06:50:04 7 0c 72 01 00 5f 01 05
1687 1687  
1688 -0005-0006 2025/5/15 01:08:43 18 0c 7e 01 f1 0d 30 2b 31 2e 33 30 2b 33 30 2e 35 0d 0a
1747 +0003-0003 2025/5/16 06:52:04 7 0c 72 01 00 5f 01 05
1689 1689  
1690 -0007-0008 2025/5/15 01:10:43 18 0c 72 01 f1 0d 30 2b 31 2e 33 30 2b 33 31 2e 30 0d 0a
1749 +0004-0004 2025/5/16 06:54:04 7 0c 7e 01 00 5f 01 05
1691 1691  
1692 -0009-0010 2025/5/15 01:12:43 18 0c 72 01 f1 0d 30 2b 31 2e 33 30 2b 33 31 2e 31 0d 0a
1751 +0005-0005 2025/5/16 06:56:04 7 0c 7e 01 00 5f 01 07
1693 1693  
1753 +0006-0006 2025/5/16 06:58:04 7 0c 8a 01 00 60 01 07
1754 +
1755 +0007-0007 2025/5/16 07:00:04 7 0c 84 01 00 61 01 07
1756 +
1757 +0008-0008 2025/5/16 07:02:04 7 0c 72 01 00 61 01 07
1758 +
1759 +0009-0009 2025/5/16 07:04:04 7 0c 78 01 00 61 01 07
1760 +
1761 +0010-0010 2025/5/16 07:06:04 7 0c 78 01 00 61 01 07
1762 +
1694 1694  Start Tx events
1695 1695  
1696 1696  OK
1697 1697  )))
1698 1698  
1768 +* **Printing in String Format:**
1769 +
1770 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
1771 +|(% style="background-color:#4f81bd; color:white; width:158px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:352px" %)**Function**
1772 +|(% style="width:156px" %)(((
1773 +AT+PLDTA=10,1
1774 +Print last 10 entries
1775 +
1776 +(((
1777 +(Printing in String Format)
1778 +)))
1779 +)))|(% style="width:311px" %)(((
1780 +Stop Tx events when read sensor data
1781 +
1782 +0001-0001 2025/5/16 06:48:04 7 ~~_
1783 +
1784 +0002-0002 2025/5/16 06:50:04 7 r_
1785 +
1786 +0003-0003 2025/5/16 06:52:04 7 r_
1787 +
1788 +0004-0004 2025/5/16 06:54:04 7 ~~_
1789 +
1790 +0005-0005 2025/5/16 06:56:04 7 ~~_
1791 +
1792 +0006-0006 2025/5/16 06:58:04 7 `
1793 +
1794 +0007-0007 2025/5/16 07:00:04 7 a
1795 +
1796 +0008-0008 2025/5/16 07:02:04 7 ra
1797 +
1798 +0009-0009 2025/5/16 07:04:04 7 xa
1799 +
1800 +0010-0010 2025/5/16 07:06:04 7 xa
1801 +
1802 +Start Tx events
1803 +
1804 +OK
1805 +)))
1806 +
1699 1699  (% style="color:#4f81bd" %)**Downlink Command:**
1700 1700  
1701 1701  No downlink commands for feature
... ... @@ -1720,7 +1720,6 @@
1720 1720  
1721 1721  * Example: 0xA301  ~/~/  Same as AT+CLRDTA
1722 1722  
1723 -
1724 1724  == 3.10 SDI12 timing(Since v1.3.0) ==
1725 1725  
1726 1726  
... ... @@ -1728,6 +1728,7 @@
1728 1728  
1729 1729  [[image:1747289896656-580.png||height="414" width="566"]]
1730 1730  
1838 +
1731 1731  (% style="color:#4f81bd" %)**AT Command: AT+SDITIMING**
1732 1732  
1733 1733  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %)
... ... @@ -1746,6 +1746,101 @@
1746 1746  
1747 1747  * Example: 0xA90D09  ~/~/  Same as AT+SDITIMING=13,9
1748 1748  
1857 +== 3.11 add Pulse_count, VDC_input, IDC_input(Since firmware V1.3.0) ==
1858 +
1859 +
1860 +(% style="color:blue" %)**Setting up external sensors:**
1861 +
1862 +* (% style="color:#037691" %)**AT Command:**
1863 +
1864 +(% style="color:#4472c4" %)**AT+EXT=a,b,c**(%%)
1865 +
1866 +(% style="color:#4472c4" %)**a:**(%%)  **0:** Disable Counting function ( doesn't effect interrupt ).  **1:** Enable Counting function(4 bytes).
1867 +(% style="color:#4472c4" %)**b: **(%%) **0:** Disable voltage acquisition function.  **1:** Enable voltage acquisition function(2 bytes)
1868 +(% style="color:#4472c4" %)**c:**(%%)  **0:** Disable current acquisition  function.  **1:** Enable current acquisition function(2 bytes).
1869 +
1870 +**Example:**
1871 +
1872 +(% style="color:#4472c4" %)**AT+EXT=1,1,1**
1873 +
1874 +Device will add counting, voltage and current acquisition function.
1875 +
1876 +The payload will be:
1877 +Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting + ** ***VDC_INPUT**  + ***IDC_INPUT**  + Length depends on the return from the commands
1878 +
1879 +(% style="color:#4472c4" %)**AT+EXT=1,0,0**
1880 +
1881 +Device will add counting support.
1882 +
1883 +The payload will be:
1884 +Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting** + Length depends on the return from the commands
1885 +
1886 +* (% style="color:#037691" %)**Downlink Command: 0x0B aa bb cc**
1887 +
1888 +Format: Command Code (0x0B) followed by 3 bytes.
1889 +
1890 +(% style="color:#037691" %)**aa:**(%%) Set Disable or Enable Counting Support.   **00**: Disable, **01**: Enable.
1891 +
1892 +(% style="color:#037691" %)**bb:**(%%) Set Disable or Enable voltage acquisition.  **00**: Disable, **01**: Enable.
1893 +
1894 +(% style="color:#037691" %)**cc:**(%%) Set Disable or Enable current acquisition.  **00**: Disable, **01**: Enable.
1895 +
1896 +**Example:**
1897 +
1898 +Downlink payload:  0B 00 00 01  ~/~/AT+EXT=0,0,1  Enable current acquisition
1899 +
1900 +Downlink payload:  0B 01 00 01  ~/~/AT+EXT=1,0,1  Enable Counting Support and Current acquisition                        
1901 +
1902 +
1903 +(% style="color:blue" %)**Set the pulse count value:**
1904 +
1905 +* (% style="color:#037691" %)**AT Command:**
1906 +
1907 +(% style="color:#4472c4" %)**AT+SETCNT=aa     **(%%)~/~/ Set the pulse count value.
1908 +
1909 +**Example:**
1910 +
1911 +AT+SETCNT=100  (% style="display:none" %) (%%)~/~/ Set the pulse count to 100.(% style="display:none" %)
1912 +
1913 +* (% style="color:#037691" %)**Downlink Command: 0x0C**
1914 +
1915 +Format: Command Code (0x0C) followed by 4 bytes.
1916 +
1917 +**Example:**
1918 +
1919 +Downlink Payload: 0C 00 00 00 64  ~/~/ AT+SETCNT=100
1920 +
1921 +
1922 +(% style="color:blue" %)**Connect counting sensor:**
1923 +
1924 +The counting sensor cables are connected to the **3V3 pin** and **GPIO_EXTI** pin of the **SIB v1.3** motherboard.
1925 +
1926 +[[image:image-20250519110640-1.jpeg||height="318" width="708"]]
1927 +
1928 +
1929 +(% id="cke_bm_1699404S" style="color:blue; display:none" %)** **(% style="color:blue" %)**Connect Voltage output sensor:**
1930 +
1931 +Example:
1932 +
1933 +**RED <~-~-~-~-> VDC_INPUT**
1934 +
1935 +**BLACK <~-~-~-~-~-~-> GND**
1936 +
1937 +[[image:image-20250519111415-3.jpeg||height="338" width="710"]]
1938 +
1939 +
1940 +(% style="color:blue" %)**Connect Current output sensor:**
1941 +
1942 +Example:
1943 +
1944 +**RED <~-~-~-~-~-~-~-~--> IDC_INPUT**
1945 +
1946 +**BLACK <~-~-~-~-~-~-> GND**
1947 +
1948 +[[image:image-20250519111732-4.jpeg||height="373" width="708"]]
1949 +
1950 +
1951 +
1749 1749  = 4. Battery & Power Consumption =
1750 1750  
1751 1751  
image-20250519110640-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +230.2 KB
Content
image-20250519111322-2.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +228.0 KB
Content
image-20250519111415-3.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +192.7 KB
Content
image-20250519111732-4.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +193.7 KB
Content
image-20250605091006-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +37.1 KB
Content