... ... @@ -513,6 +513,8 @@
513 513  
514 514  (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
515 515  
516 +(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)**
517 +
516 516  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
517 517  
518 518  (% style="color:red" %)**0 **(%%) No validation check;
... ... @@ -677,12 +677,46 @@
677 677  
678 678  (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
679 679  
682 +* (% style="color:blue" %)**Downlink Command:**
680 680  
684 +Format: Command code (0xAC) followed by up to 20 bytes.
685 +
686 +
687 +Example 1 1:AT+DATACONVx=var1, var2   
688 +
689 +Downlink Command:AC x var1  var2
690 +
691 +Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 
692 +
693 +Downlink Command:AC x var1  var2  var3 var4
694 +
695 +Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6
696 +
697 +Downlink Command:AC x var1  var2  var3 var4 var5 var6
698 +
699 +Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8
700 +
701 +Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8
702 +
703 +Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10
704 +
705 +Downlink Command:AC x var1  var2  var3 var4 var5 var6 var7 var8 var9 var10
706 +
707 +
708 +Example:
709 +
710 +* Example 1: Downlink Payload: AC 01 01 02 02 02  ~/~/  AT+DATACONV1=1,2+2,2 
711 +* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02  ~/~/  AT+DATACONV2=1,2+2,2+3,2
712 +
713 +
714 +
715 +
716 +
681 681  **For example:**
682 682  
683 683  This is my configuration:
684 684  
685 -[[image:image-20250516103205-2.png]]
721 +[[image:image-20250605091006-1.png]]
686 686  
687 687  
688 688  * AT+COMMAND1=0C!,0,2,0  After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately.
... ... @@ -689,20 +689,30 @@
689 689  * AT+COMMAND2=0M!,1,2,0  After sending the concurrent command of device 0, do not cut the data and wait for one second. (The last concurrent command needs to wait for the measurement time of all sensors)
690 690  * AT+COMMAND3=0D0!,0,0,0  Query the data measured by device 0
691 691  
692 -
693 693  This is the data obtained:
694 694  
695 -[[image:image-20250516103652-3.png]]
730 +[[image:image-20250516145402-2.png]]
696 696  
697 697  
698 698  When using the AT+DATACONVx command,
699 699  
700 -The data of RETURN3 will be converted into 2 data, the first data is +101, and the second data is +263.
735 +The data of RETURN3 will be converted into 2 data, the first data is +95, and the second data is +260.
701 701  
702 702  * AT+DATACONV3=1,2+2,2  The first data is uploaded as 2 bytes and the second data is uploaded as 2 bytes. The form converted to hexadecimal is as shown above,as below:
703 703  
739 +[[image:image-20250516144559-1.png]]
704 704  
741 +0C90 01 005F 0104
705 705  
743 +(% style="color:#037691" %)**BAT**(%%): 0x0c90 = 3216mV = 3.216V
744 +
745 +(% style="color:#037691" %)**Payload Version**(%%): 0x01, Means: v1.0 version
746 +
747 +(% style="color:#037691" %)**Data 1: **(%%)0x005F(H) = 95(D) / 100 = 0.95
748 +
749 +(% style="color:#037691" %)**Data 2: **(%%)0x0104(H) = 260(D) / 10 = 26.0
750 +
751 +
706 706  == 2.4 Uplink Payload ==
707 707  
708 708  === 2.4.1 Device Payload, FPORT~=5 ===
... ... @@ -1370,7 +1370,11 @@
1370 1370  
1371 1371  **SDI-12-LB will uplink this payload.**
1372 1372  
1373 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A
1419 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **
1420 +68253C5D 12 0C7801F10D302B312E31372B32372E340D0A
1421 +68253D33 12 0C7201F10D302B312E31352B32382E390D0A
1422 +68253DAB 12 0C7201F10D302B312E31342B32392E340D0A
1423 +68253E23 12 0C7201F10D302B312E31332B33302E300D0A
1374 1374  
1375 1375  
1376 1376  Where the first 23 bytes is for the first entry:
... ... @@ -1624,7 +1624,7 @@
1624 1624  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1625 1625  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1626 1626  
1627 -=== 3.7 Print data entries base on page(Since v1.3.0) ===
1677 +== 3.7 Print data entries base on page(Since v1.3.0) ==
1628 1628  
1629 1629  
1630 1630  Feature: Print the sector data from start page to stop page (max is 416 pages).
... ... @@ -1668,7 +1668,7 @@
1668 1668  No downlink commands for feature
1669 1669  
1670 1670  
1671 -=== 3.8 Print last few data entries(Since v1.3.0) ===
1721 +== 3.8 Print last few data entries(Since v1.3.0) ==
1672 1672  
1673 1673  
1674 1674  Feature: Print the last few data entries
... ... @@ -1675,29 +1675,85 @@
1675 1675  
1676 1676  (% style="color:#4f81bd" %)**AT Command: AT+PLDTA**
1677 1677  
1728 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:437px" %)
1729 +|=(% style="width: 158px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 192px;background-color:#4F81BD;color:white" %)**Function**
1730 +|(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,0|(% style="background-color:#f2f2f2; width:192px" %)Printing the last ten data in hex format
1731 +|(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,1|(% style="background-color:#f2f2f2; width:192px" %)Print the last ten data in string format
1732 +
1733 +* **Prints in hex format:**
1734 +
1678 1678  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
1679 1679  |(% style="background-color:#4f81bd; color:white; width:158px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:352px" %)**Function**
1680 1680  |(% style="width:156px" %)(((
1681 -AT+PLDTA=10
1738 +AT+PLDTA=10,0
1682 1682  Print last 10 entries
1683 1683  )))|(% style="width:311px" %)(((
1684 1684  Stop Tx events when read sensor data
1685 1685  
1686 -0001-0002 2025/5/15 01:04:43 18 0c 72 01 f1 0d 30 2b 31 2e 31 34 2b 32 39 2e 34 0d 0a
1743 +0001-0001 2025/5/16 06:48:04 7 0c 7e 01 00 5f 01 05
1687 1687  
1688 -0003-0004 2025/5/15 01:06:43 18 0c 72 01 f1 0d 30 2b 31 2e 31 33 2b 33 30 2e 30 0d 0a
1745 +0002-0002 2025/5/16 06:50:04 7 0c 72 01 00 5f 01 05
1689 1689  
1690 -0005-0006 2025/5/15 01:08:43 18 0c 7e 01 f1 0d 30 2b 31 2e 33 30 2b 33 30 2e 35 0d 0a
1747 +0003-0003 2025/5/16 06:52:04 7 0c 72 01 00 5f 01 05
1691 1691  
1692 -0007-0008 2025/5/15 01:10:43 18 0c 72 01 f1 0d 30 2b 31 2e 33 30 2b 33 31 2e 30 0d 0a
1749 +0004-0004 2025/5/16 06:54:04 7 0c 7e 01 00 5f 01 05
1693 1693  
1694 -0009-0010 2025/5/15 01:12:43 18 0c 72 01 f1 0d 30 2b 31 2e 33 30 2b 33 31 2e 31 0d 0a
1751 +0005-0005 2025/5/16 06:56:04 7 0c 7e 01 00 5f 01 07
1695 1695  
1753 +0006-0006 2025/5/16 06:58:04 7 0c 8a 01 00 60 01 07
1754 +
1755 +0007-0007 2025/5/16 07:00:04 7 0c 84 01 00 61 01 07
1756 +
1757 +0008-0008 2025/5/16 07:02:04 7 0c 72 01 00 61 01 07
1758 +
1759 +0009-0009 2025/5/16 07:04:04 7 0c 78 01 00 61 01 07
1760 +
1761 +0010-0010 2025/5/16 07:06:04 7 0c 78 01 00 61 01 07
1762 +
1696 1696  Start Tx events
1697 1697  
1698 1698  OK
1699 1699  )))
1700 1700  
1768 +* **Printing in String Format:**
1769 +
1770 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
1771 +|(% style="background-color:#4f81bd; color:white; width:158px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:352px" %)**Function**
1772 +|(% style="width:156px" %)(((
1773 +AT+PLDTA=10,1
1774 +Print last 10 entries
1775 +
1776 +(((
1777 +(Printing in String Format)
1778 +)))
1779 +)))|(% style="width:311px" %)(((
1780 +Stop Tx events when read sensor data
1781 +
1782 +0001-0001 2025/5/16 06:48:04 7 ~~_
1783 +
1784 +0002-0002 2025/5/16 06:50:04 7 r_
1785 +
1786 +0003-0003 2025/5/16 06:52:04 7 r_
1787 +
1788 +0004-0004 2025/5/16 06:54:04 7 ~~_
1789 +
1790 +0005-0005 2025/5/16 06:56:04 7 ~~_
1791 +
1792 +0006-0006 2025/5/16 06:58:04 7 `
1793 +
1794 +0007-0007 2025/5/16 07:00:04 7 a
1795 +
1796 +0008-0008 2025/5/16 07:02:04 7 ra
1797 +
1798 +0009-0009 2025/5/16 07:04:04 7 xa
1799 +
1800 +0010-0010 2025/5/16 07:06:04 7 xa
1801 +
1802 +Start Tx events
1803 +
1804 +OK
1805 +)))
1806 +
1701 1701  (% style="color:#4f81bd" %)**Downlink Command:**
1702 1702  
1703 1703  No downlink commands for feature
... ... @@ -1722,8 +1722,6 @@
1722 1722  
1723 1723  * Example: 0xA301  ~/~/  Same as AT+CLRDTA
1724 1724  
1725 -
1726 -
1727 1727  == 3.10 SDI12 timing(Since v1.3.0) ==
1728 1728  
1729 1729  
... ... @@ -1731,6 +1731,7 @@
1731 1731  
1732 1732  [[image:1747289896656-580.png||height="414" width="566"]]
1733 1733  
1838 +
1734 1734  (% style="color:#4f81bd" %)**AT Command: AT+SDITIMING**
1735 1735  
1736 1736  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %)
... ... @@ -1749,6 +1749,101 @@
1749 1749  
1750 1750  * Example: 0xA90D09  ~/~/  Same as AT+SDITIMING=13,9
1751 1751  
1857 +== 3.11 add Pulse_count, VDC_input, IDC_input(Since firmware V1.3.0) ==
1858 +
1859 +
1860 +(% style="color:blue" %)**Setting up external sensors:**
1861 +
1862 +* (% style="color:#037691" %)**AT Command:**
1863 +
1864 +(% style="color:#4472c4" %)**AT+EXT=a,b,c**(%%)
1865 +
1866 +(% style="color:#4472c4" %)**a:**(%%)  **0:** Disable Counting function ( doesn't effect interrupt ).  **1:** Enable Counting function(4 bytes).
1867 +(% style="color:#4472c4" %)**b: **(%%) **0:** Disable voltage acquisition function.  **1:** Enable voltage acquisition function(2 bytes)
1868 +(% style="color:#4472c4" %)**c:**(%%)  **0:** Disable current acquisition  function.  **1:** Enable current acquisition function(2 bytes).
1869 +
1870 +**Example:**
1871 +
1872 +(% style="color:#4472c4" %)**AT+EXT=1,1,1**
1873 +
1874 +Device will add counting, voltage and current acquisition function.
1875 +
1876 +The payload will be:
1877 +Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting + ** ***VDC_INPUT**  + ***IDC_INPUT**  + Length depends on the return from the commands
1878 +
1879 +(% style="color:#4472c4" %)**AT+EXT=1,0,0**
1880 +
1881 +Device will add counting support.
1882 +
1883 +The payload will be:
1884 +Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting** + Length depends on the return from the commands
1885 +
1886 +* (% style="color:#037691" %)**Downlink Command: 0x0B aa bb cc**
1887 +
1888 +Format: Command Code (0x0B) followed by 3 bytes.
1889 +
1890 +(% style="color:#037691" %)**aa:**(%%) Set Disable or Enable Counting Support.   **00**: Disable, **01**: Enable.
1891 +
1892 +(% style="color:#037691" %)**bb:**(%%) Set Disable or Enable voltage acquisition.  **00**: Disable, **01**: Enable.
1893 +
1894 +(% style="color:#037691" %)**cc:**(%%) Set Disable or Enable current acquisition.  **00**: Disable, **01**: Enable.
1895 +
1896 +**Example:**
1897 +
1898 +Downlink payload:  0B 00 00 01  ~/~/AT+EXT=0,0,1  Enable current acquisition
1899 +
1900 +Downlink payload:  0B 01 00 01  ~/~/AT+EXT=1,0,1  Enable Counting Support and Current acquisition                        
1901 +
1902 +
1903 +(% style="color:blue" %)**Set the pulse count value:**
1904 +
1905 +* (% style="color:#037691" %)**AT Command:**
1906 +
1907 +(% style="color:#4472c4" %)**AT+SETCNT=aa     **(%%)~/~/ Set the pulse count value.
1908 +
1909 +**Example:**
1910 +
1911 +AT+SETCNT=100  (% style="display:none" %) (%%)~/~/ Set the pulse count to 100.(% style="display:none" %)
1912 +
1913 +* (% style="color:#037691" %)**Downlink Command: 0x0C**
1914 +
1915 +Format: Command Code (0x0C) followed by 4 bytes.
1916 +
1917 +**Example:**
1918 +
1919 +Downlink Payload: 0C 00 00 00 64  ~/~/ AT+SETCNT=100
1920 +
1921 +
1922 +(% style="color:blue" %)**Connect counting sensor:**
1923 +
1924 +The counting sensor cables are connected to the **3V3 pin** and **GPIO_EXTI** pin of the **SIB v1.3** motherboard.
1925 +
1926 +[[image:image-20250519110640-1.jpeg||height="318" width="708"]]
1927 +
1928 +
1929 +(% id="cke_bm_1699404S" style="color:blue; display:none" %)** **(% style="color:blue" %)**Connect Voltage output sensor:**
1930 +
1931 +Example:
1932 +
1933 +**RED <~-~-~-~-> VDC_INPUT**
1934 +
1935 +**BLACK <~-~-~-~-~-~-> GND**
1936 +
1937 +[[image:image-20250519111415-3.jpeg||height="338" width="710"]]
1938 +
1939 +
1940 +(% style="color:blue" %)**Connect Current output sensor:**
1941 +
1942 +Example:
1943 +
1944 +**RED <~-~-~-~-~-~-~-~--> IDC_INPUT**
1945 +
1946 +**BLACK <~-~-~-~-~-~-> GND**
1947 +
1948 +[[image:image-20250519111732-4.jpeg||height="373" width="708"]]
1949 +
1950 +
1951 +
1752 1752  = 4. Battery & Power Consumption =
1753 1753  
1754 1754  
image-20250516144559-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +55.1 KB
Content
image-20250516145402-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +9.6 KB
Content
image-20250519110640-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +230.2 KB
Content
image-20250519111322-2.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +228.0 KB
Content
image-20250519111415-3.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@