Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 152.2
edited by Mengting Qiu
on 2025/05/16 11:30
on 2025/05/16 11:30
Change comment:
There is no comment for this version
To version 167.1
edited by Mengting Qiu
on 2025/06/09 10:23
on 2025/06/09 10:23
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -513,6 +513,8 @@ 513 513 514 514 (% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)** 515 515 516 +(% style="color:red" %)**(When set to 2, AT+ALDATAMOD=1 does not intercept data returned by the current COMMAND command.)** 517 + 516 516 (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries. 517 517 518 518 (% style="color:red" %)**0 **(%%) No validation check; ... ... @@ -677,12 +677,45 @@ 677 677 678 678 (% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.** 679 679 682 +* (% style="color:blue" %)**Downlink Command:** 680 680 684 +Format: Command code (0xAC) followed by up to 20 bytes. 685 + 686 + 687 +Example 1 1:AT+DATACONVx=var1, var2 688 + 689 +Downlink Command:AC x var1 var2 690 + 691 +Example 1 2:AT+DATACONVx=var1, var2+ var3, var4 692 + 693 +Downlink Command:AC x var1 var2 var3 var4 694 + 695 +Example 1 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6 696 + 697 +Downlink Command:AC x var1 var2 var3 var4 var5 var6 698 + 699 +Example 1 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8 700 + 701 +Downlink Command:AC x var1 var2 var3 var4 var5 var6 var7 var8 702 + 703 +Example 1 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10 704 + 705 +Downlink Command:AC x var1 var2 var3 var4 var5 var6 var7 var8 var9 var10 706 + 707 + 708 +Example: 709 + 710 +* Example 1: Downlink Payload: AC 01 01 02 02 02 ~/~/ AT+DATACONV1=1,2+2,2 711 +* Example 2: Downlink Payload: AC 02 01 02 02 02 03 02 ~/~/ AT+DATACONV2=1,2+2,2+3,2 712 + 713 + 714 + 715 + 681 681 **For example:** 682 682 683 683 This is my configuration: 684 684 685 -[[image:image-2025051 6103205-2.png]]720 +[[image:image-20250605091006-1.png]] 686 686 687 687 688 688 * AT+COMMAND1=0C!,0,2,0 After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately. ... ... @@ -689,20 +689,30 @@ 689 689 * AT+COMMAND2=0M!,1,2,0 After sending the concurrent command of device 0, do not cut the data and wait for one second. (The last concurrent command needs to wait for the measurement time of all sensors) 690 690 * AT+COMMAND3=0D0!,0,0,0 Query the data measured by device 0 691 691 692 - 693 693 This is the data obtained: 694 694 695 -[[image:image-202505161 03652-3.png]]729 +[[image:image-20250516145402-2.png]] 696 696 697 697 698 698 When using the AT+DATACONVx command, 699 699 700 -The data of RETURN3 will be converted into 2 data, the first data is + 101, and the second data is +263.734 +The data of RETURN3 will be converted into 2 data, the first data is +95, and the second data is +260. 701 701 702 702 * AT+DATACONV3=1,2+2,2 The first data is uploaded as 2 bytes and the second data is uploaded as 2 bytes. The form converted to hexadecimal is as shown above,as below: 703 703 738 +[[image:image-20250516144559-1.png]] 704 704 740 +0C90 01 005F 0104 705 705 742 +(% style="color:#037691" %)**BAT**(%%): 0x0c90 = 3216mV = 3.216V 743 + 744 +(% style="color:#037691" %)**Payload Version**(%%): 0x01, Means: v1.0 version 745 + 746 +(% style="color:#037691" %)**Data 1: **(%%)0x005F(H) = 95(D) / 100 = 0.95 747 + 748 +(% style="color:#037691" %)**Data 2: **(%%)0x0104(H) = 260(D) / 10 = 26.0 749 + 750 + 706 706 == 2.4 Uplink Payload == 707 707 708 708 === 2.4.1 Device Payload, FPORT~=5 === ... ... @@ -1370,7 +1370,11 @@ 1370 1370 1371 1371 **SDI-12-LB will uplink this payload.** 1372 1372 1373 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A 1418 +**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A ** 1419 +68253C5D 12 0C7801F10D302B312E31372B32372E340D0A 1420 +68253D33 12 0C7201F10D302B312E31352B32382E390D0A 1421 +68253DAB 12 0C7201F10D302B312E31342B32392E340D0A 1422 +68253E23 12 0C7201F10D302B312E31332B33302E300D0A 1374 1374 1375 1375 1376 1376 Where the first 23 bytes is for the first entry: ... ... @@ -1624,7 +1624,7 @@ 1624 1624 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1625 1625 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1626 1626 1627 -== =3.7 Print data entries base on page(Since v1.3.0) ===1676 +== 3.7 Print data entries base on page(Since v1.3.0) == 1628 1628 1629 1629 1630 1630 Feature: Print the sector data from start page to stop page (max is 416 pages). ... ... @@ -1668,7 +1668,7 @@ 1668 1668 No downlink commands for feature 1669 1669 1670 1670 1671 -== =3.8 Print last few data entries(Since v1.3.0) ===1720 +== 3.8 Print last few data entries(Since v1.3.0) == 1672 1672 1673 1673 1674 1674 Feature: Print the last few data entries ... ... @@ -1675,35 +1675,91 @@ 1675 1675 1676 1676 (% style="color:#4f81bd" %)**AT Command: AT+PLDTA** 1677 1677 1727 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:437px" %) 1728 +|=(% style="width: 158px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 192px;background-color:#4F81BD;color:white" %)**Function** 1729 +|(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,0|(% style="background-color:#f2f2f2; width:192px" %)Printing the last ten data in hex format 1730 +|(% style="background-color:#f2f2f2; width:158px" %)AT+PLDTA=10,1|(% style="background-color:#f2f2f2; width:192px" %)Print the last ten data in string format 1731 + 1732 +* **Prints in hex format:** 1733 + 1678 1678 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1679 1679 |(% style="background-color:#4f81bd; color:white; width:158px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:352px" %)**Function** 1680 1680 |(% style="width:156px" %)((( 1681 -AT+PLDTA=10 1737 +AT+PLDTA=10,0 1682 1682 Print last 10 entries 1683 1683 )))|(% style="width:311px" %)((( 1684 1684 Stop Tx events when read sensor data 1685 1685 1686 -0001-000 22025/5/1501:04:43180c 7201f10d 302b312e 31 34 2b 32 39 2e 340d 0a1742 +0001-0001 2025/5/16 06:48:04 7 0c 7e 01 00 5f 01 05 1687 1687 1688 -000 3-00042025/5/1501:06:43180c 72 01f10d 302b312e 31 33 2b 33 302e 30 0d 0a1744 +0002-0002 2025/5/16 06:50:04 7 0c 72 01 00 5f 01 05 1689 1689 1690 -000 5-00062025/5/1501:08:43180c 7e01f10d 302b 31 2e 33 30 2b 33 30 2e 35 0d0a1746 +0003-0003 2025/5/16 06:52:04 7 0c 72 01 00 5f 01 05 1691 1691 1692 -000 7-00082025/5/1501:10:43180c 7201f10d 302b31 2e 33 302b 33 312e 300d 0a1748 +0004-0004 2025/5/16 06:54:04 7 0c 7e 01 00 5f 01 05 1693 1693 1694 -000 9-0010 2025/5/1501:12:43180c 7201f10d 302b31 2e 33 302b 33 312e 310d 0a1750 +0005-0005 2025/5/16 06:56:04 7 0c 7e 01 00 5f 01 07 1695 1695 1752 +0006-0006 2025/5/16 06:58:04 7 0c 8a 01 00 60 01 07 1753 + 1754 +0007-0007 2025/5/16 07:00:04 7 0c 84 01 00 61 01 07 1755 + 1756 +0008-0008 2025/5/16 07:02:04 7 0c 72 01 00 61 01 07 1757 + 1758 +0009-0009 2025/5/16 07:04:04 7 0c 78 01 00 61 01 07 1759 + 1760 +0010-0010 2025/5/16 07:06:04 7 0c 78 01 00 61 01 07 1761 + 1696 1696 Start Tx events 1697 1697 1698 1698 OK 1699 1699 ))) 1700 1700 1767 +* **Printing in String Format:** 1768 + 1769 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1770 +|(% style="background-color:#4f81bd; color:white; width:158px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:352px" %)**Function** 1771 +|(% style="width:156px" %)((( 1772 +AT+PLDTA=10,1 1773 +Print last 10 entries 1774 + 1775 +((( 1776 +(Printing in String Format) 1777 +))) 1778 +)))|(% style="width:311px" %)((( 1779 +Stop Tx events when read sensor data 1780 + 1781 +0001-0001 2025/5/16 06:48:04 7 ~~_ 1782 + 1783 +0002-0002 2025/5/16 06:50:04 7 r_ 1784 + 1785 +0003-0003 2025/5/16 06:52:04 7 r_ 1786 + 1787 +0004-0004 2025/5/16 06:54:04 7 ~~_ 1788 + 1789 +0005-0005 2025/5/16 06:56:04 7 ~~_ 1790 + 1791 +0006-0006 2025/5/16 06:58:04 7 ` 1792 + 1793 +0007-0007 2025/5/16 07:00:04 7 a 1794 + 1795 +0008-0008 2025/5/16 07:02:04 7 ra 1796 + 1797 +0009-0009 2025/5/16 07:04:04 7 xa 1798 + 1799 +0010-0010 2025/5/16 07:06:04 7 xa 1800 + 1801 +Start Tx events 1802 + 1803 +OK 1804 +))) 1805 + 1701 1701 (% style="color:#4f81bd" %)**Downlink Command:** 1702 1702 1703 1703 No downlink commands for feature 1704 1704 1705 1705 1706 -== =3.9 Clear Flash Record(Since v1.3.0) ===1811 +== 3.9 Clear Flash Record(Since v1.3.0) == 1707 1707 1708 1708 1709 1709 Feature: Clear flash storage for data log feature. ... ... @@ -1722,8 +1722,6 @@ 1722 1722 1723 1723 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1724 1724 1725 - 1726 - 1727 1727 == 3.10 SDI12 timing(Since v1.3.0) == 1728 1728 1729 1729 ... ... @@ -1731,6 +1731,7 @@ 1731 1731 1732 1732 [[image:1747289896656-580.png||height="414" width="566"]] 1733 1733 1837 + 1734 1734 (% style="color:#4f81bd" %)**AT Command: AT+SDITIMING** 1735 1735 1736 1736 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %) ... ... @@ -1749,6 +1749,101 @@ 1749 1749 1750 1750 * Example: 0xA90D09 ~/~/ Same as AT+SDITIMING=13,9 1751 1751 1856 +== 3.11 add Pulse_count, VDC_input, IDC_input(Since firmware V1.3.0) == 1857 + 1858 + 1859 +(% style="color:blue" %)**Setting up external sensors:** 1860 + 1861 +* (% style="color:#037691" %)**AT Command:** 1862 + 1863 +(% style="color:#4472c4" %)**AT+EXT=a,b,c**(%%) 1864 + 1865 +(% style="color:#4472c4" %)**a:**(%%) **0:** Disable Counting function ( doesn't effect interrupt ). **1:** Enable Counting function(4 bytes). 1866 +(% style="color:#4472c4" %)**b: **(%%) **0:** Disable voltage acquisition function. **1:** Enable voltage acquisition function(2 bytes) 1867 +(% style="color:#4472c4" %)**c:**(%%) **0:** Disable current acquisition function. **1:** Enable current acquisition function(2 bytes). 1868 + 1869 +**Example:** 1870 + 1871 +(% style="color:#4472c4" %)**AT+EXT=1,1,1** 1872 + 1873 +Device will add counting, voltage and current acquisition function. 1874 + 1875 +The payload will be: 1876 +Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting + ** ***VDC_INPUT** + ***IDC_INPUT** + Length depends on the return from the commands 1877 + 1878 +(% style="color:#4472c4" %)**AT+EXT=1,0,0** 1879 + 1880 +Device will add counting support. 1881 + 1882 +The payload will be: 1883 +Battery(mV) & Interrupt _Flag + PAYLOAD_VER + ***counting** + Length depends on the return from the commands 1884 + 1885 +* (% style="color:#037691" %)**Downlink Command: 0x0B aa bb cc** 1886 + 1887 +Format: Command Code (0x0B) followed by 3 bytes. 1888 + 1889 +(% style="color:#037691" %)**aa:**(%%) Set Disable or Enable Counting Support. **00**: Disable, **01**: Enable. 1890 + 1891 +(% style="color:#037691" %)**bb:**(%%) Set Disable or Enable voltage acquisition. **00**: Disable, **01**: Enable. 1892 + 1893 +(% style="color:#037691" %)**cc:**(%%) Set Disable or Enable current acquisition. **00**: Disable, **01**: Enable. 1894 + 1895 +**Example:** 1896 + 1897 +Downlink payload: 0B 00 00 01 ~/~/AT+EXT=0,0,1 Enable current acquisition 1898 + 1899 +Downlink payload: 0B 01 00 01 ~/~/AT+EXT=1,0,1 Enable Counting Support and Current acquisition 1900 + 1901 + 1902 +(% style="color:blue" %)**Set the pulse count value:** 1903 + 1904 +* (% style="color:#037691" %)**AT Command:** 1905 + 1906 +(% style="color:#4472c4" %)**AT+SETCNT=aa **(%%)~/~/ Set the pulse count value. 1907 + 1908 +**Example:** 1909 + 1910 +AT+SETCNT=100 (% style="display:none" %) (%%)~/~/ Set the pulse count to 100.(% style="display:none" %) 1911 + 1912 +* (% style="color:#037691" %)**Downlink Command: 0x0C** 1913 + 1914 +Format: Command Code (0x0C) followed by 4 bytes. 1915 + 1916 +**Example:** 1917 + 1918 +Downlink Payload: 0C 00 00 00 64 ~/~/ AT+SETCNT=100 1919 + 1920 + 1921 +(% style="color:blue" %)**Connect counting sensor:** 1922 + 1923 +The counting sensor cables are connected to the **3V3 pin** and **GPIO_EXTI** pin of the **SIB v1.3** motherboard. 1924 + 1925 +[[image:image-20250519110640-1.jpeg||height="318" width="708"]] 1926 + 1927 + 1928 +(% id="cke_bm_1699404S" style="color:blue; display:none" %)** **(% style="color:blue" %)**Connect Voltage output sensor:** 1929 + 1930 +Example: 1931 + 1932 +**RED <~-~-~-~-> VDC_INPUT** 1933 + 1934 +**BLACK <~-~-~-~-~-~-> GND** 1935 + 1936 +[[image:image-20250519111415-3.jpeg||height="338" width="710"]] 1937 + 1938 + 1939 +(% style="color:blue" %)**Connect Current output sensor:** 1940 + 1941 +Example: 1942 + 1943 +**RED <~-~-~-~-~-~-~-~--> IDC_INPUT** 1944 + 1945 +**BLACK <~-~-~-~-~-~-> GND** 1946 + 1947 +[[image:image-20250519111732-4.jpeg||height="373" width="708"]] 1948 + 1949 + 1950 + 1752 1752 = 4. Battery & Power Consumption = 1753 1753 1754 1754
- image-20250516144559-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +55.1 KB - Content
- image-20250516145402-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.6 KB - Content
- image-20250519110640-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +230.2 KB - Content
- image-20250519111322-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +228.0 KB - Content
- image-20250519111415-3.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +192.7 KB - Content
- image-20250519111732-4.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +193.7 KB - Content
- image-20250605091006-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.1 KB - Content