Last modified by Mengting Qiu on 2025/07/03 15:42

From version 152.1
edited by Mengting Qiu
on 2025/05/16 10:37
Change comment: Uploaded new attachment "image-20250516103652-3.png", version {1}
To version 148.1
edited by Mengting Qiu
on 2025/05/15 14:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -498,7 +498,7 @@
498 498  === 2.3.4 Define periodically SDI-12 commands and uplink. ===
499 499  
500 500  
501 -AT+COMMANDx & AT+DATACUTx**&AT+DATACONVx**
501 +AT+COMMANDx & AT+DATACUTx
502 502  
503 503  User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB/LS will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB/LS will then combine these returns and uplink via LoRaWAN.
504 504  
... ... @@ -511,7 +511,7 @@
511 511  
512 512  (% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second)
513 513  
514 -(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
514 +(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//.
515 515  
516 516  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
517 517  
... ... @@ -654,44 +654,6 @@
654 654  (% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**
655 655  
656 656  
657 -
658 -(% style="color:blue" %)**Automatically converts polled data to hex format for uplinking(Since v1.3.0)**
659 -
660 -
661 -This command can retrieve the returned data, convert the number after the positive or negative sign into a data, and then set the number of bytes to upload the data.
662 -
663 -
664 -* (% style="color:blue" %)**AT Command:**
665 -
666 -The maximum number can be set to 5 groups and the format of the command is as follows:
667 -
668 -(% style="color:#037691" %)**Example 1:AT+DATACONVx=var1, var2**
669 -
670 -(% style="color:#037691" %)**Example 2:AT+DATACONVx=var1, var2+ var3, var4**
671 -
672 -(% style="color:#037691" %)**Example 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6**
673 -
674 -(% style="color:#037691" %)**Example 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8**
675 -
676 -(% style="color:#037691" %)**Example 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10**
677 -
678 -(% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
679 -
680 -
681 -**For example:**
682 -
683 -This is my configuration:
684 -
685 -[[image:image-20250516100849-1.png]]
686 -
687 -
688 -AT+COMMAND1=0C!,0,2,0  After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately.
689 -
690 -AT+COMMAND2=0M!,2,1,0  After sending the concurrent command of device 0, do not cut the data and wait for one second. (The last concurrent command needs to wait for the measurement time of all sensors)
691 -
692 -
693 -
694 -
695 695  == 2.4 Uplink Payload ==
696 696  
697 697  === 2.4.1 Device Payload, FPORT~=5 ===
... ... @@ -1613,7 +1613,7 @@
1613 1613  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1614 1614  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1615 1615  
1616 -=== 3.7 Print data entries base on page(Since v1.3.0) ===
1578 +=== 3.7 Print data entries base on page ===
1617 1617  
1618 1618  
1619 1619  Feature: Print the sector data from start page to stop page (max is 416 pages).
... ... @@ -1657,7 +1657,7 @@
1657 1657  No downlink commands for feature
1658 1658  
1659 1659  
1660 -=== 3.8 Print last few data entries(Since v1.3.0) ===
1622 +=== 3.8 Print last few data entries ===
1661 1661  
1662 1662  
1663 1663  Feature: Print the last few data entries
... ... @@ -1692,7 +1692,7 @@
1692 1692  No downlink commands for feature
1693 1693  
1694 1694  
1695 -=== 3.9 Clear Flash Record(Since v1.3.0) ===
1657 +=== 3.9 Clear Flash Record ===
1696 1696  
1697 1697  
1698 1698  Feature: Clear flash storage for data log feature.
... ... @@ -1713,7 +1713,7 @@
1713 1713  
1714 1714  
1715 1715  
1716 -== 3.10 SDI12 timing(Since v1.3.0) ==
1678 +== 3.10 SDI12 timing ==
1717 1717  
1718 1718  
1719 1719  Feature: Get or set the time of SDI12 timing.
... ... @@ -1738,6 +1738,8 @@
1738 1738  
1739 1739  * Example: 0xA90D09  ~/~/  Same as AT+SDITIMING=13,9
1740 1740  
1703 +
1704 +
1741 1741  = 4. Battery & Power Consumption =
1742 1742  
1743 1743  
image-20250516100849-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.ting
Size
... ... @@ -1,1 +1,0 @@
1 -37.2 KB
Content
image-20250516103205-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.ting
Size
... ... @@ -1,1 +1,0 @@
1 -37.3 KB
Content
image-20250516103652-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.ting
Size
... ... @@ -1,1 +1,0 @@
1 -14.5 KB
Content