Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 150.3
edited by Mengting Qiu
on 2025/05/16 10:22
on 2025/05/16 10:22
Change comment:
There is no comment for this version
To version 145.1
edited by Mengting Qiu
on 2025/05/15 09:36
on 2025/05/15 09:36
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -498,7 +498,7 @@ 498 498 === 2.3.4 Define periodically SDI-12 commands and uplink. === 499 499 500 500 501 -AT+COMMANDx & AT+DATACUTx **&AT+DATACONVx**501 +AT+COMMANDx & AT+DATACUTx 502 502 503 503 User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB/LS will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB/LS will then combine these returns and uplink via LoRaWAN. 504 504 ... ... @@ -511,7 +511,7 @@ 511 511 512 512 (% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second) 513 513 514 -(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**514 +(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. 515 515 516 516 (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries. 517 517 ... ... @@ -654,44 +654,6 @@ 654 654 (% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.** 655 655 656 656 657 - 658 -(% style="color:blue" %)**Automatically converts polled data to hex format for uplinking(Since v1.3.0)** 659 - 660 - 661 -This command can retrieve the returned data, convert the number after the positive or negative sign into a data, and then set the number of bytes to upload the data. 662 - 663 - 664 -* (% style="color:blue" %)**AT Command:** 665 - 666 -The maximum number can be set to 5 groups and the format of the command is as follows: 667 - 668 -(% style="color:#037691" %)**Example 1:AT+DATACONVx=var1, var2** 669 - 670 -(% style="color:#037691" %)**Example 2:AT+DATACONVx=var1, var2+ var3, var4** 671 - 672 -(% style="color:#037691" %)**Example 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6** 673 - 674 -(% style="color:#037691" %)**Example 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8** 675 - 676 -(% style="color:#037691" %)**Example 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10** 677 - 678 -(% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.** 679 - 680 - 681 -**For example:** 682 - 683 -This is my configuration: 684 - 685 -[[image:image-20250516100849-1.png]] 686 - 687 - 688 -AT+COMMAND1=0C!,0,2,0 After sending the concurrent command of device 0, the data will not be cut, and the next command will be sent immediately. 689 - 690 -AT+COMMAND2=0M!,2,1,0 After sending the concurrent command of device 0, do not cut the data and wait for one second. (The last concurrent command needs to wait for the measurement time of all sensors) 691 - 692 - 693 - 694 - 695 695 == 2.4 Uplink Payload == 696 696 697 697 === 2.4.1 Device Payload, FPORT~=5 === ... ... @@ -1350,31 +1350,31 @@ 1350 1350 2025/3/25 08:16:30 1351 1351 )))|(% style="width:82px" %)5|(% style="width:86px" %)0c ae|(% style="width:92px" %)01|(% style="width:131px" %)08 22 1352 1352 1353 -If user sends below downlink command: (% style="background-color:yellow" %)316 8253B6E68253E23051315 +If user sends below downlink command: (% style="background-color:yellow" %)3167E264BA67E2665E05 1354 1354 1355 -Where : Start time: (% _mstmutation="1" %)68253B6E(%%)= time 2025/05/15 00:55:101317 +Where : Start time: 67E264BA = time 2025/3/25 08:09:30 1356 1356 1357 - Stop time: (% _mstmutation="1" %)68253E23 (%%)= time 2025/05/15 01:06:431319 + Stop time: 67E2665E= time 2025/3/25 08:16:30 1358 1358 1359 1359 1360 1360 **SDI-12-LB will uplink this payload.** 1361 1361 1362 -**6 8253B6E120C7801F10D302B312E31372B32362E390D0A**68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A1324 +**67E264BA 05 0CA8 01 0821** 67E264F6050CAE01082267E26532050CAE01082267E2656E050CAE01082267E265AA050CB401082367E265E6050CAE01082267E26622050CB401082367E2665E050CAE010822 1363 1363 1364 1364 1365 -Where the first 23bytes is for the first entry:1327 +Where the first 10 bytes is for the first entry: 1366 1366 1367 - **68253B6E127801F10D302B312E31372B32362E390D0A**1329 +67E264BA050CA8010821 1368 1368 1369 -Unix Time Stamp: 6 8253B6E(H)=1747270510(D) ~-~-> time=2025-05-15 8:55:001331 +Unix Time Stamp: 67E264BA(H)=1742890170(D) ~-~-> time=2025-03-25 8:09:30 1370 1370 1371 -Payload Length: 0x 12(H)=18bytes1333 +Payload Length: 0x05(H)=5 bytes 1372 1372 1373 -Battery voltage: 0x0C 78(H)=3192 mV1335 +Battery voltage: 0x0CA8(H)=3240 mV 1374 1374 1375 1375 Payload Version: 01 1376 1376 1377 -Value: For the distance sensor used for testing, this value is the mm distance value, 0x F10D302B312E31372B32362E390D0A(H)1339 +Value: For the distance sensor used for testing, this value is the mm distance value, 0x0821(H)=2081mm. 1378 1378 1379 1379 1380 1380 ... ... @@ -1613,9 +1613,10 @@ 1613 1613 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1614 1614 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1615 1615 1616 -=== 3.7 Print data entries base on page(Since v1.3.0) === 1617 1617 1579 +=== 3.7 Print data entries base on page === 1618 1618 1581 + 1619 1619 Feature: Print the sector data from start page to stop page (max is 416 pages). 1620 1620 1621 1621 (% style="color:#4f81bd" %)**AT Command: AT+PDTA** ... ... @@ -1657,7 +1657,7 @@ 1657 1657 No downlink commands for feature 1658 1658 1659 1659 1660 -=== 3.8 Print last few data entries (Sincev1.3.0)===1623 +=== 3.8 Print last few data entries === 1661 1661 1662 1662 1663 1663 Feature: Print the last few data entries ... ... @@ -1692,7 +1692,7 @@ 1692 1692 No downlink commands for feature 1693 1693 1694 1694 1695 -=== 3.9 Clear Flash Record (Sincev1.3.0)===1658 +=== 3.9 Clear Flash Record === 1696 1696 1697 1697 1698 1698 Feature: Clear flash storage for data log feature. ... ... @@ -1712,32 +1712,6 @@ 1712 1712 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1713 1713 1714 1714 1715 - 1716 -== 3.10 SDI12 timing(Since v1.3.0) == 1717 - 1718 - 1719 -Feature: Get or set the time of SDI12 timing. 1720 - 1721 -[[image:1747289896656-580.png||height="414" width="566"]] 1722 - 1723 -(% style="color:#4f81bd" %)**AT Command: AT+SDITIMING** 1724 - 1725 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %) 1726 -|(% style="background-color:#4f81bd; color:white; width:157px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:167px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:177px" %)**Response** 1727 -|(% style="width:155px" %)((( 1728 -AT+SDITIMING=13,9 1729 - 1730 - 1731 -)))|(% style="width:167px" %)Get or set the time of SDI12 timing|(% style="width:177px" %)((( 1732 -OK 1733 - 1734 -Default: 13,9 1735 -))) 1736 - 1737 -(% style="color:#4f81bd" %)**Downlink Command: 0xA9** 1738 - 1739 -* Example: 0xA90D09 ~/~/ Same as AT+SDITIMING=13,9 1740 - 1741 1741 = 4. Battery & Power Consumption = 1742 1742 1743 1743
- 1747289896656-580.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -37.0 KB - Content
- image-20250516100849-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -37.2 KB - Content