Last modified by Mengting Qiu on 2025/07/03 15:42

From version 150.2
edited by Mengting Qiu
on 2025/05/16 10:12
Change comment: There is no comment for this version
To version 148.1
edited by Mengting Qiu
on 2025/05/15 14:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -498,7 +498,7 @@
498 498  === 2.3.4 Define periodically SDI-12 commands and uplink. ===
499 499  
500 500  
501 -AT+COMMANDx & AT+DATACUTx**&AT+DATACONVx**
501 +AT+COMMANDx & AT+DATACUTx
502 502  
503 503  User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB/LS will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB/LS will then combine these returns and uplink via LoRaWAN.
504 504  
... ... @@ -511,7 +511,7 @@
511 511  
512 512  (% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second)
513 513  
514 -(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
514 +(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//.
515 515  
516 516  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
517 517  
... ... @@ -654,38 +654,6 @@
654 654  (% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**
655 655  
656 656  
657 -
658 -(% style="color:blue" %)**Automatically converts polled data to hex format for uplinking(Since v1.3.0)**
659 -
660 -
661 -This command can retrieve the returned data, convert the number after the positive or negative sign into a data, and then set the number of bytes to upload the data.
662 -
663 -
664 -* (% style="color:blue" %)**AT Command:**
665 -
666 -The maximum number can be set to 5 groups and the format of the command is as follows:
667 -
668 -(% style="color:#037691" %)**Example 1:AT+DATACONVx=var1, var2**
669 -
670 -(% style="color:#037691" %)**Example 2:AT+DATACONVx=var1, var2+ var3, var4**
671 -
672 -(% style="color:#037691" %)**Example 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6**
673 -
674 -(% style="color:#037691" %)**Example 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8**
675 -
676 -(% style="color:#037691" %)**Example 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10**
677 -
678 -(% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
679 -
680 -
681 -**For example:**
682 -
683 -This is my configuration:
684 -
685 -[[image:image-20250516100849-1.png]]
686 -
687 -
688 -
689 689  == 2.4 Uplink Payload ==
690 690  
691 691  === 2.4.1 Device Payload, FPORT~=5 ===
... ... @@ -1607,7 +1607,7 @@
1607 1607  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1608 1608  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1609 1609  
1610 -=== 3.7 Print data entries base on page(Since v1.3.0) ===
1578 +=== 3.7 Print data entries base on page ===
1611 1611  
1612 1612  
1613 1613  Feature: Print the sector data from start page to stop page (max is 416 pages).
... ... @@ -1651,7 +1651,7 @@
1651 1651  No downlink commands for feature
1652 1652  
1653 1653  
1654 -=== 3.8 Print last few data entries(Since v1.3.0) ===
1622 +=== 3.8 Print last few data entries ===
1655 1655  
1656 1656  
1657 1657  Feature: Print the last few data entries
... ... @@ -1686,7 +1686,7 @@
1686 1686  No downlink commands for feature
1687 1687  
1688 1688  
1689 -=== 3.9 Clear Flash Record(Since v1.3.0) ===
1657 +=== 3.9 Clear Flash Record ===
1690 1690  
1691 1691  
1692 1692  Feature: Clear flash storage for data log feature.
... ... @@ -1707,7 +1707,7 @@
1707 1707  
1708 1708  
1709 1709  
1710 -== 3.10 SDI12 timing(Since v1.3.0) ==
1678 +== 3.10 SDI12 timing ==
1711 1711  
1712 1712  
1713 1713  Feature: Get or set the time of SDI12 timing.
... ... @@ -1732,6 +1732,8 @@
1732 1732  
1733 1733  * Example: 0xA90D09  ~/~/  Same as AT+SDITIMING=13,9
1734 1734  
1703 +
1704 +
1735 1735  = 4. Battery & Power Consumption =
1736 1736  
1737 1737  
image-20250516100849-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.ting
Size
... ... @@ -1,1 +1,0 @@
1 -37.2 KB
Content