Last modified by Mengting Qiu on 2025/07/03 15:42

From version 150.2
edited by Mengting Qiu
on 2025/05/16 10:12
Change comment: There is no comment for this version
To version 144.4
edited by Mengting Qiu
on 2025/05/15 09:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -498,7 +498,7 @@
498 498  === 2.3.4 Define periodically SDI-12 commands and uplink. ===
499 499  
500 500  
501 -AT+COMMANDx & AT+DATACUTx**&AT+DATACONVx**
501 +AT+COMMANDx & AT+DATACUTx
502 502  
503 503  User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB/LS will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB/LS will then combine these returns and uplink via LoRaWAN.
504 504  
... ... @@ -511,7 +511,7 @@
511 511  
512 512  (% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second)
513 513  
514 -(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
514 +(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//.
515 515  
516 516  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
517 517  
... ... @@ -654,38 +654,6 @@
654 654  (% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**
655 655  
656 656  
657 -
658 -(% style="color:blue" %)**Automatically converts polled data to hex format for uplinking(Since v1.3.0)**
659 -
660 -
661 -This command can retrieve the returned data, convert the number after the positive or negative sign into a data, and then set the number of bytes to upload the data.
662 -
663 -
664 -* (% style="color:blue" %)**AT Command:**
665 -
666 -The maximum number can be set to 5 groups and the format of the command is as follows:
667 -
668 -(% style="color:#037691" %)**Example 1:AT+DATACONVx=var1, var2**
669 -
670 -(% style="color:#037691" %)**Example 2:AT+DATACONVx=var1, var2+ var3, var4**
671 -
672 -(% style="color:#037691" %)**Example 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6**
673 -
674 -(% style="color:#037691" %)**Example 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8**
675 -
676 -(% style="color:#037691" %)**Example 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10**
677 -
678 -(% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
679 -
680 -
681 -**For example:**
682 -
683 -This is my configuration:
684 -
685 -[[image:image-20250516100849-1.png]]
686 -
687 -
688 -
689 689  == 2.4 Uplink Payload ==
690 690  
691 691  === 2.4.1 Device Payload, FPORT~=5 ===
... ... @@ -1344,31 +1344,31 @@
1344 1344  2025/3/25 08:16:30
1345 1345  )))|(% style="width:82px" %)5|(% style="width:86px" %)0c ae|(% style="width:92px" %)01|(% style="width:131px" %)08 22
1346 1346  
1347 -If user sends below downlink command: (% style="background-color:yellow" %)3168253B6E68253E2305
1315 +If user sends below downlink command: (% style="background-color:yellow" %)3167E264BA67E2665E05
1348 1348  
1349 -Where : Start time: (% _mstmutation="1" %)68253B6E (%%)= time 2025/05/15 00:55:10
1317 +Where : Start time: 67E264BA = time 2025/3/25 08:09:30
1350 1350  
1351 - Stop time: (% _mstmutation="1" %)68253E23 (%%)= time 2025/05/15 01:06:43
1319 + Stop time: 67E2665E= time 2025/3/25 08:16:30
1352 1352  
1353 1353  
1354 1354  **SDI-12-LB will uplink this payload.**
1355 1355  
1356 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A **68253C5D120C7801F10D302B312E31372B32372E340D0A68253D33120C7201F10D302B312E31352B32382E390D0A68253DAB120C7201F10D302B312E31342B32392E340D0A68253E23120C7201F10D302B312E31332B33302E300D0A
1324 +**67E264BA 05 0CA8 01 0821** 67E264F6050CAE01082267E26532050CAE01082267E2656E050CAE01082267E265AA050CB401082367E265E6050CAE01082267E26622050CB401082367E2665E050CAE010822
1357 1357  
1358 1358  
1359 -Where the first 23 bytes is for the first entry:
1327 +Where the first 10 bytes is for the first entry:
1360 1360  
1361 -**68253B6E 12 0C7801F10D302B312E31372B32362E390D0A**
1329 +67E264BA050CA8010821
1362 1362  
1363 -Unix Time Stamp: 68253B6E(H)=1747270510(D)  ~-~->  time=2025-05-15 8:55:00
1331 +Unix Time Stamp: 67E264BA(H)=1742890170(D)  ~-~->  time=2025-03-25 8:09:30
1364 1364  
1365 -Payload Length: 0x12(H)=18 bytes
1333 +Payload Length: 0x05(H)=5 bytes
1366 1366  
1367 -Battery voltage: 0x0C78(H)=3192 mV
1335 +Battery voltage: 0x0CA8(H)=3240 mV
1368 1368  
1369 1369  Payload Version:  01
1370 1370  
1371 -Value: For the distance sensor used for testing, this value is the mm distance value, 0xF10D302B312E31372B32362E390D0A(H)
1339 +Value: For the distance sensor used for testing, this value is the mm distance value, 0x0821(H)=2081mm.
1372 1372  
1373 1373  
1374 1374  
... ... @@ -1607,9 +1607,10 @@
1607 1607  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1608 1608  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1609 1609  
1610 -=== 3.7 Print data entries base on page(Since v1.3.0) ===
1611 1611  
1579 +=== 3.7 Print data entries base on page ===
1612 1612  
1581 +
1613 1613  Feature: Print the sector data from start page to stop page (max is 416 pages).
1614 1614  
1615 1615  (% style="color:#4f81bd" %)**AT Command: AT+PDTA**
... ... @@ -1651,7 +1651,7 @@
1651 1651  No downlink commands for feature
1652 1652  
1653 1653  
1654 -=== 3.8 Print last few data entries(Since v1.3.0) ===
1623 +=== 3.8 Print last few data entries ===
1655 1655  
1656 1656  
1657 1657  Feature: Print the last few data entries
... ... @@ -1686,7 +1686,7 @@
1686 1686  No downlink commands for feature
1687 1687  
1688 1688  
1689 -=== 3.9 Clear Flash Record(Since v1.3.0) ===
1658 +=== 3.9 Clear Flash Record ===
1690 1690  
1691 1691  
1692 1692  Feature: Clear flash storage for data log feature.
... ... @@ -1706,32 +1706,6 @@
1706 1706  * Example: 0xA301  ~/~/  Same as AT+CLRDTA
1707 1707  
1708 1708  
1709 -
1710 -== 3.10 SDI12 timing(Since v1.3.0) ==
1711 -
1712 -
1713 -Feature: Get or set the time of SDI12 timing.
1714 -
1715 -[[image:1747289896656-580.png||height="414" width="566"]]
1716 -
1717 -(% style="color:#4f81bd" %)**AT Command: AT+SDITIMING**
1718 -
1719 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %)
1720 -|(% style="background-color:#4f81bd; color:white; width:157px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:167px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:177px" %)**Response**
1721 -|(% style="width:155px" %)(((
1722 -AT+SDITIMING=13,9
1723 -
1724 -
1725 -)))|(% style="width:167px" %)Get or set the time of SDI12 timing|(% style="width:177px" %)(((
1726 -OK
1727 -
1728 -Default: 13,9
1729 -)))
1730 -
1731 -(% style="color:#4f81bd" %)**Downlink Command: 0xA9**
1732 -
1733 -* Example: 0xA90D09  ~/~/  Same as AT+SDITIMING=13,9
1734 -
1735 1735  = 4. Battery & Power Consumption =
1736 1736  
1737 1737  
1747289896656-580.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.ting
Size
... ... @@ -1,1 +1,0 @@
1 -37.0 KB
Content
image-20250516100849-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.ting
Size
... ... @@ -1,1 +1,0 @@
1 -37.2 KB
Content