Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 149.3
edited by Mengting Qiu
on 2025/05/16 09:55
on 2025/05/16 09:55
Change comment:
There is no comment for this version
To version 149.1
edited by Mengting Qiu
on 2025/05/15 14:25
on 2025/05/15 14:25
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -498,7 +498,7 @@ 498 498 === 2.3.4 Define periodically SDI-12 commands and uplink. === 499 499 500 500 501 -AT+COMMANDx & AT+DATACUTx **&AT+DATACONVx**501 +AT+COMMANDx & AT+DATACUTx 502 502 503 503 User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB/LS will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB/LS will then combine these returns and uplink via LoRaWAN. 504 504 ... ... @@ -511,7 +511,7 @@ 511 511 512 512 (% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second) 513 513 514 -(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**514 +(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. 515 515 516 516 (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries. 517 517 ... ... @@ -654,31 +654,6 @@ 654 654 (% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.** 655 655 656 656 657 - 658 -(% style="color:blue" %)**Automatically converts polled data to hex format for uplinking(Since v1.3.0)** 659 - 660 - 661 -This command can retrieve the returned data, convert the number after the positive or negative sign into a data, and then set the number of bytes to upload the data. 662 - 663 - 664 -* (% style="color:blue" %)**AT Command:** 665 - 666 -The maximum number can be set to 5 groups and the format of the command is as follows: 667 - 668 -(% style="color:#037691" %)**Example 1:AT+DATACONVx=var1, var2** 669 - 670 -(% style="color:#037691" %)**Example 2:AT+DATACONVx=var1, var2+ var3, var4** 671 - 672 -(% style="color:#037691" %)**Example 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6** 673 - 674 -(% style="color:#037691" %)**Example 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8** 675 - 676 -(% style="color:#037691" %)**Example 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10** 677 - 678 -(% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.** 679 - 680 - 681 - 682 682 == 2.4 Uplink Payload == 683 683 684 684 === 2.4.1 Device Payload, FPORT~=5 === ... ... @@ -1699,7 +1699,6 @@ 1699 1699 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1700 1700 1701 1701 1702 - 1703 1703 == 3.10 SDI12 timing(Since v1.3.0) == 1704 1704 1705 1705 ... ... @@ -1725,6 +1725,7 @@ 1725 1725 1726 1726 * Example: 0xA90D09 ~/~/ Same as AT+SDITIMING=13,9 1727 1727 1702 + 1728 1728 = 4. Battery & Power Consumption = 1729 1729 1730 1730