... ... @@ -498,7 +498,7 @@
498 498  === 2.3.4 Define periodically SDI-12 commands and uplink. ===
499 499  
500 500  
501 -AT+COMMANDx & AT+DATACUTx**&AT+DATACONVx**
501 +AT+COMMANDx & AT+DATACUTx
502 502  
503 503  User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB/LS will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB/LS will then combine these returns and uplink via LoRaWAN.
504 504  
... ... @@ -511,7 +511,7 @@
511 511  
512 512  (% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second)
513 513  
514 -(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
514 +(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//.
515 515  
516 516  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
517 517  
... ... @@ -654,31 +654,6 @@
654 654  (% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**
655 655  
656 656  
657 -
658 -(% style="color:blue" %)**Automatically converts polled data to hex format for uplinking(Since v1.3.0)**
659 -
660 -
661 -This command can retrieve the returned data, convert the number after the positive or negative sign into a data, and then set the number of bytes to upload the data.
662 -
663 -
664 -* (% style="color:blue" %)**AT Command:**
665 -
666 -The maximum number can be set to 5 groups and the format of the command is as follows:
667 -
668 -(% style="color:#037691" %)**Example 1:AT+DATACONVx=var1, var2**
669 -
670 -(% style="color:#037691" %)**Example 2:AT+DATACONVx=var1, var2+ var3, var4**
671 -
672 -(% style="color:#037691" %)**Example 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6**
673 -
674 -(% style="color:#037691" %)**Example 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8**
675 -
676 -(% style="color:#037691" %)**Example 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10**
677 -
678 -(% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
679 -
680 -
681 -
682 682  == 2.4 Uplink Payload ==
683 683  
684 684  === 2.4.1 Device Payload, FPORT~=5 ===
... ... @@ -1600,7 +1600,7 @@
1600 1600  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1601 1601  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1602 1602  
1603 -=== 3.7 Print data entries base on page(Since v1.3.0) ===
1578 +=== 3.7 Print data entries base on page ===
1604 1604  
1605 1605  
1606 1606  Feature: Print the sector data from start page to stop page (max is 416 pages).
... ... @@ -1644,7 +1644,7 @@
1644 1644  No downlink commands for feature
1645 1645  
1646 1646  
1647 -=== 3.8 Print last few data entries(Since v1.3.0) ===
1622 +=== 3.8 Print last few data entries ===
1648 1648  
1649 1649  
1650 1650  Feature: Print the last few data entries
... ... @@ -1679,7 +1679,7 @@
1679 1679  No downlink commands for feature
1680 1680  
1681 1681  
1682 -=== 3.9 Clear Flash Record(Since v1.3.0) ===
1657 +=== 3.9 Clear Flash Record ===
1683 1683  
1684 1684  
1685 1685  Feature: Clear flash storage for data log feature.
... ... @@ -1698,33 +1698,6 @@
1698 1698  
1699 1699  * Example: 0xA301  ~/~/  Same as AT+CLRDTA
1700 1700  
1701 -
1702 -
1703 -== 3.10 SDI12 timing(Since v1.3.0) ==
1704 -
1705 -
1706 -Feature: Get or set the time of SDI12 timing.
1707 -
1708 -[[image:1747289896656-580.png||height="414" width="566"]]
1709 -
1710 -(% style="color:#4f81bd" %)**AT Command: AT+SDITIMING**
1711 -
1712 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %)
1713 -|(% style="background-color:#4f81bd; color:white; width:157px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:167px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:177px" %)**Response**
1714 -|(% style="width:155px" %)(((
1715 -AT+SDITIMING=13,9
1716 -
1717 -
1718 -)))|(% style="width:167px" %)Get or set the time of SDI12 timing|(% style="width:177px" %)(((
1719 -OK
1720 -
1721 -Default: 13,9
1722 -)))
1723 -
1724 -(% style="color:#4f81bd" %)**Downlink Command: 0xA9**
1725 -
1726 -* Example: 0xA90D09  ~/~/  Same as AT+SDITIMING=13,9
1727 -
1728 1728  = 4. Battery & Power Consumption =
1729 1729  
1730 1730