Last modified by Mengting Qiu on 2025/07/03 15:42

From version 148.1
edited by Mengting Qiu
on 2025/05/15 14:19
Change comment: There is no comment for this version
To version 149.3
edited by Mengting Qiu
on 2025/05/16 09:55
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -498,7 +498,7 @@
498 498  === 2.3.4 Define periodically SDI-12 commands and uplink. ===
499 499  
500 500  
501 -AT+COMMANDx & AT+DATACUTx
501 +AT+COMMANDx & AT+DATACUTx**&AT+DATACONVx**
502 502  
503 503  User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB/LS will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB/LS will then combine these returns and uplink via LoRaWAN.
504 504  
... ... @@ -511,7 +511,7 @@
511 511  
512 512  (% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second)
513 513  
514 -(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//.
514 +(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)**
515 515  
516 516  (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries.
517 517  
... ... @@ -654,6 +654,31 @@
654 654  (% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.**
655 655  
656 656  
657 +
658 +(% style="color:blue" %)**Automatically converts polled data to hex format for uplinking(Since v1.3.0)**
659 +
660 +
661 +This command can retrieve the returned data, convert the number after the positive or negative sign into a data, and then set the number of bytes to upload the data.
662 +
663 +
664 +* (% style="color:blue" %)**AT Command:**
665 +
666 +The maximum number can be set to 5 groups and the format of the command is as follows:
667 +
668 +(% style="color:#037691" %)**Example 1:AT+DATACONVx=var1, var2**
669 +
670 +(% style="color:#037691" %)**Example 2:AT+DATACONVx=var1, var2+ var3, var4**
671 +
672 +(% style="color:#037691" %)**Example 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6**
673 +
674 +(% style="color:#037691" %)**Example 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8**
675 +
676 +(% style="color:#037691" %)**Example 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10**
677 +
678 +(% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.**
679 +
680 +
681 +
657 657  == 2.4 Uplink Payload ==
658 658  
659 659  === 2.4.1 Device Payload, FPORT~=5 ===
... ... @@ -1575,7 +1575,7 @@
1575 1575  * Example 1: Downlink Payload: AE 01  ~/~/  AT+PAYVER=1
1576 1576  * Example 2: Downlink Payload: AE 05  ~/~/  AT+PAYVER=5
1577 1577  
1578 -=== 3.7 Print data entries base on page ===
1603 +=== 3.7 Print data entries base on page(Since v1.3.0) ===
1579 1579  
1580 1580  
1581 1581  Feature: Print the sector data from start page to stop page (max is 416 pages).
... ... @@ -1619,7 +1619,7 @@
1619 1619  No downlink commands for feature
1620 1620  
1621 1621  
1622 -=== 3.8 Print last few data entries ===
1647 +=== 3.8 Print last few data entries(Since v1.3.0) ===
1623 1623  
1624 1624  
1625 1625  Feature: Print the last few data entries
... ... @@ -1654,7 +1654,7 @@
1654 1654  No downlink commands for feature
1655 1655  
1656 1656  
1657 -=== 3.9 Clear Flash Record ===
1682 +=== 3.9 Clear Flash Record(Since v1.3.0) ===
1658 1658  
1659 1659  
1660 1660  Feature: Clear flash storage for data log feature.
... ... @@ -1675,7 +1675,7 @@
1675 1675  
1676 1676  
1677 1677  
1678 -== 3.10 SDI12 timing ==
1703 +== 3.10 SDI12 timing(Since v1.3.0) ==
1679 1679  
1680 1680  
1681 1681  Feature: Get or set the time of SDI12 timing.
... ... @@ -1700,8 +1700,6 @@
1700 1700  
1701 1701  * Example: 0xA90D09  ~/~/  Same as AT+SDITIMING=13,9
1702 1702  
1703 -
1704 -
1705 1705  = 4. Battery & Power Consumption =
1706 1706  
1707 1707