Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Mengting Qiu on 2025/07/03 15:42
From version 145.2
edited by Mengting Qiu
on 2025/05/15 10:06
on 2025/05/15 10:06
Change comment:
There is no comment for this version
To version 149.3
edited by Mengting Qiu
on 2025/05/16 09:55
on 2025/05/16 09:55
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -498,7 +498,7 @@ 498 498 === 2.3.4 Define periodically SDI-12 commands and uplink. === 499 499 500 500 501 -AT+COMMANDx & AT+DATACUTx 501 +AT+COMMANDx & AT+DATACUTx**&AT+DATACONVx** 502 502 503 503 User can define max 15 SDI-12 Commands (AT+COMMAND1 ~~ AT+COMMANDF). On each uplink period (TDC time, default 20 minutes), SDI-12-LB/LS will send these SDI-12 commands and wait for return from SDI-12 sensors. SDI-12-LB/LS will then combine these returns and uplink via LoRaWAN. 504 504 ... ... @@ -511,7 +511,7 @@ 511 511 512 512 (% style="color:red" %)**var2**(%%): Wait timeout for return. (unit: second) 513 513 514 -(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. 514 +(% style="color:red" %)**var3**(%%): Whether to send //addrD0!// to get return after var2 timeout. 0: Don't Send //addrD0! //; 1: Send //addrD0!//. (% style="color:red" %)**2: The returned data will not be clipped.(since v1.3.0)** 515 515 516 516 (% style="color:red" %)**var4**(%%): validation check for return. If return invalid, SDI-12-LB/LS will resend this command. Max 3 retries. 517 517 ... ... @@ -654,6 +654,31 @@ 654 654 (% style="color:red" %)**When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value.** 655 655 656 656 657 + 658 +(% style="color:blue" %)**Automatically converts polled data to hex format for uplinking(Since v1.3.0)** 659 + 660 + 661 +This command can retrieve the returned data, convert the number after the positive or negative sign into a data, and then set the number of bytes to upload the data. 662 + 663 + 664 +* (% style="color:blue" %)**AT Command:** 665 + 666 +The maximum number can be set to 5 groups and the format of the command is as follows: 667 + 668 +(% style="color:#037691" %)**Example 1:AT+DATACONVx=var1, var2** 669 + 670 +(% style="color:#037691" %)**Example 2:AT+DATACONVx=var1, var2+ var3, var4** 671 + 672 +(% style="color:#037691" %)**Example 3:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6** 673 + 674 +(% style="color:#037691" %)**Example 4:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8** 675 + 676 +(% style="color:#037691" %)**Example 5:AT+DATACONVx=var1, var2+ var3, var4+ var5, var6+ var7, var8+ var9, var10** 677 + 678 +(% style="color:red" %)**Notice: Among them, var1, var3, var5, var7, and var9 are the data to be selected for conversion, and var2, var4, var6, var8, and var10 are the number of bytes to be uploaded. The values of var2, var4, var6, var8, and var10 range from 1 to 4.** 679 + 680 + 681 + 657 657 == 2.4 Uplink Payload == 658 658 659 659 === 2.4.1 Device Payload, FPORT~=5 === ... ... @@ -1575,7 +1575,7 @@ 1575 1575 * Example 1: Downlink Payload: AE 01 ~/~/ AT+PAYVER=1 1576 1576 * Example 2: Downlink Payload: AE 05 ~/~/ AT+PAYVER=5 1577 1577 1578 -=== 3.7 Print data entries base on page === 1603 +=== 3.7 Print data entries base on page(Since v1.3.0) === 1579 1579 1580 1580 1581 1581 Feature: Print the sector data from start page to stop page (max is 416 pages). ... ... @@ -1619,7 +1619,7 @@ 1619 1619 No downlink commands for feature 1620 1620 1621 1621 1622 -=== 3.8 Print last few data entries === 1647 +=== 3.8 Print last few data entries(Since v1.3.0) === 1623 1623 1624 1624 1625 1625 Feature: Print the last few data entries ... ... @@ -1654,7 +1654,7 @@ 1654 1654 No downlink commands for feature 1655 1655 1656 1656 1657 -=== 3.9 Clear Flash Record === 1682 +=== 3.9 Clear Flash Record(Since v1.3.0) === 1658 1658 1659 1659 1660 1660 Feature: Clear flash storage for data log feature. ... ... @@ -1673,6 +1673,33 @@ 1673 1673 1674 1674 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1675 1675 1701 + 1702 + 1703 +== 3.10 SDI12 timing(Since v1.3.0) == 1704 + 1705 + 1706 +Feature: Get or set the time of SDI12 timing. 1707 + 1708 +[[image:1747289896656-580.png||height="414" width="566"]] 1709 + 1710 +(% style="color:#4f81bd" %)**AT Command: AT+SDITIMING** 1711 + 1712 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:503px" %) 1713 +|(% style="background-color:#4f81bd; color:white; width:157px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:167px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:177px" %)**Response** 1714 +|(% style="width:155px" %)((( 1715 +AT+SDITIMING=13,9 1716 + 1717 + 1718 +)))|(% style="width:167px" %)Get or set the time of SDI12 timing|(% style="width:177px" %)((( 1719 +OK 1720 + 1721 +Default: 13,9 1722 +))) 1723 + 1724 +(% style="color:#4f81bd" %)**Downlink Command: 0xA9** 1725 + 1726 +* Example: 0xA90D09 ~/~/ Same as AT+SDITIMING=13,9 1727 + 1676 1676 = 4. Battery & Power Consumption = 1677 1677 1678 1678
- 1747289896656-580.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.0 KB - Content