Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -47,7 +47,7 @@ 47 47 ))) 48 48 49 49 ((( 50 -SDI-12-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%) or (% style="color:blue" %)**solar powered + Li-ion battery**(%%) it is designed for long term use up to 5 years.50 +SDI-12-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%) or (% style="color:blue" %)**solar powered + li-on battery**(%%) it is designed for long term use up to 5 years. 51 51 ))) 52 52 53 53 ((( ... ... @@ -72,7 +72,7 @@ 72 72 * Uplink on periodically 73 73 * Downlink to change configure 74 74 * 8500mAh Li/SOCl2 Battery (SDI-12-LB) 75 -* Solar panel + 3000mAh Li- ion battery (SDI-12-LS)75 +* Solar panel + 3000mAh Li-on battery (SDI-12-LS) 76 76 77 77 == 1.3 Specification == 78 78 ... ... @@ -1095,7 +1095,7 @@ 1095 1095 [[image:image-20240423162322-4.png||height="269" width="933"]] 1096 1096 1097 1097 1098 -=== 2.6.8 Example 8 ~-~- Connect to Acclima TDR Soil Moisture Sensor===1098 +=== 2.6.8 Example 8 ~-~- Connect to GroPoint Profile-8 (SDI-12 Version) === 1099 1099 1100 1100 ==== 2.6.8.1 Reference Manual and Command ==== 1101 1101 ... ... @@ -1114,7 +1114,6 @@ 1114 1114 1115 1115 [[image:image-20240903152627-2.png]] 1116 1116 1117 - 1118 1118 ==== 2.6.8.2 Hardware Connection to SDI-12-LB/LS ==== 1119 1119 1120 1120 ... ... @@ -1122,10 +1122,8 @@ 1122 1122 1123 1123 [[image:image-20240903153004-5.png||height="358" width="660"]] 1124 1124 1125 - 1126 1126 ==== 2.6.8.3 Commands set in SDI-12-LB/LS and uplink payload ==== 1127 1127 1128 - 1129 1129 [[image:image-20240903153258-6.png]] 1130 1130 1131 1131 [[image:image-20240903153627-7.png]] ... ... @@ -1134,7 +1134,6 @@ 1134 1134 1135 1135 [[image:image-20240903154020-10.png||height="467" width="961"]] 1136 1136 1137 - 1138 1138 == 2.7 Frequency Plans == 1139 1139 1140 1140 ... ... @@ -1206,7 +1206,6 @@ 1206 1206 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1207 1207 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1208 1208 1209 - 1210 1210 == 3.2 Set Interrupt Mode == 1211 1211 1212 1212 ... ... @@ -1238,8 +1238,6 @@ 1238 1238 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1239 1239 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1240 1240 1241 - 1242 - 1243 1243 == 3.3 Set the output time == 1244 1244 1245 1245 ... ... @@ -1311,8 +1311,6 @@ 1311 1311 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 1312 1312 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1313 1313 1314 - 1315 - 1316 1316 == 3.4 Set the all data mode == 1317 1317 1318 1318 ... ... @@ -1335,8 +1335,6 @@ 1335 1335 * Example 1: Downlink Payload: AB 00 ~/~/ AT+ALLDATAMOD=0 1336 1336 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1337 1337 1338 - 1339 - 1340 1340 == 3.5 Set the splicing payload for uplink == 1341 1341 1342 1342