Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
Uploaded new attachment "image-20241118164859-1.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.ting - Content
-
... ... @@ -47,7 +47,7 @@ 47 47 ))) 48 48 49 49 ((( 50 -SDI-12-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%) or (% style="color:blue" %)**solar powered + li-on battery**(%%) it is designed for long term use up to 5 years.50 +SDI-12-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%) or (% style="color:blue" %)**solar powered + Li-ion battery,**(%%) it is designed for long term use up to 5 years. 51 51 ))) 52 52 53 53 ((( ... ... @@ -72,7 +72,7 @@ 72 72 * Uplink on periodically 73 73 * Downlink to change configure 74 74 * 8500mAh Li/SOCl2 Battery (SDI-12-LB) 75 -* Solar panel + 3000mAh Li-on battery (SDI-12-LS) 75 +* Solar panel + 3000mAh Li-ion battery (SDI-12-LS) 76 76 77 77 == 1.3 Specification == 78 78 ... ... @@ -1056,7 +1056,7 @@ 1056 1056 [[image:image-20230627180303-6.png||height="292" width="1171"]] 1057 1057 1058 1058 1059 -=== 2.6.7 Example 6~-~- Connect to GroPoint Profile-8 (SDI-12 Version) ===1059 +=== 2.6.7 Example 7 ~-~- Connect to GroPoint Profile-8 (SDI-12 Version) === 1060 1060 1061 1061 ==== 2.6.7.1 Reference Manual and Command ==== 1062 1062 ... ... @@ -1095,6 +1095,46 @@ 1095 1095 [[image:image-20240423162322-4.png||height="269" width="933"]] 1096 1096 1097 1097 1098 +=== 2.6.8 Example 8 ~-~- Connect to Acclima TDR Soil Moisture Sensor === 1099 + 1100 +==== 2.6.8.1 Reference Manual and Command ==== 1101 + 1102 + 1103 +* [[Acclima TDR Soil Moisture Sensor User Manual>>url:https://acclima.com/tdr-soil-moisture-sensor-user-manual/]] 1104 + 1105 +* Commands to be used in PC and output. 1106 + 1107 +1. check device address 1108 +1. change device address 1109 +1. check device ID 1110 +1. start measure 1111 +1. Get Meausre result 1112 + 1113 +[[image:image-20240903152650-3.png]] 1114 + 1115 +[[image:image-20240903152627-2.png]] 1116 + 1117 + 1118 +==== 2.6.8.2 Hardware Connection to SDI-12-LB/LS ==== 1119 + 1120 + 1121 +(% style="color:red" %)**Note: When the bytes returned by the sensor are not fixed, the full byte interception can be used: AT+ALLDATAMOD=1 (The DATACUTx parameter needs to be cleared when using this directive, or it will not work.)** 1122 + 1123 +[[image:image-20240903153004-5.png||height="358" width="660"]] 1124 + 1125 + 1126 +==== 2.6.8.3 Commands set in SDI-12-LB/LS and uplink payload ==== 1127 + 1128 + 1129 +[[image:image-20240903153258-6.png]] 1130 + 1131 +[[image:image-20240903153627-7.png]] 1132 + 1133 +DATA in TTN: 1134 + 1135 +[[image:image-20240903154020-10.png||height="467" width="961"]] 1136 + 1137 + 1098 1098 == 2.7 Frequency Plans == 1099 1099 1100 1100 ... ... @@ -1197,6 +1197,7 @@ 1197 1197 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1198 1198 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1199 1199 1240 + 1200 1200 == 3.3 Set the output time == 1201 1201 1202 1202 ... ... @@ -1268,6 +1268,7 @@ 1268 1268 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 1269 1269 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 1270 1270 1312 + 1271 1271 == 3.4 Set the all data mode == 1272 1272 1273 1273 ... ... @@ -1290,6 +1290,7 @@ 1290 1290 * Example 1: Downlink Payload: AB 00 ~/~/ AT+ALLDATAMOD=0 1291 1291 * Example 2: Downlink Payload: AB 01 ~/~/ AT+ALLDATAMOD=1 1292 1292 1335 + 1293 1293 == 3.5 Set the splicing payload for uplink == 1294 1294 1295 1295
- image-20241118164859-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.6 KB - Content