Changes for page SDI-12-LB/LS -- SDI-12 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/25 08:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Bei - Content
-
... ... @@ -151,7 +151,7 @@ 151 151 (% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 152 152 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 153 153 ))) 154 -|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means S DI-12-LB/LSis in Deep Sleep Mode.154 +|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 155 155 156 156 == 1.7 Pin Mapping == 157 157 ... ... @@ -205,7 +205,7 @@ 205 205 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example. 206 206 207 207 208 -[[image:image-20230201090528-5.png||_mstalt="430300" height="4 42" width="1056"]]208 +[[image:image-20230201090528-5.png||_mstalt="430300" height="465" width="1111"]] 209 209 210 210 211 211 The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. ... ... @@ -596,6 +596,7 @@ 596 596 If AT+ALLDATAMOD=1, (% style="color:#4f81bd" %)**FX,X**(%%) will be added in the payload, FX specify which command is used and X specify the length of return. for example in above screen, F1 05 means the return is from AT+COMMAND1 and the return is 5 bytes. 597 597 598 598 599 + 599 599 (% style="color:blue" %)**Compose Uplink** 600 600 601 601 (% style="color:#4f81bd" %)**AT+DATAUP=0** ... ... @@ -932,6 +932,7 @@ 932 932 [[image:image-20230603121826-11.png||height="155" width="1104"]] 933 933 934 934 936 + 935 935 === 2.6.4 Example 4 ~-~- Connect to TEROS-12 === 936 936 937 937 ==== 2.6.4.1 Reference Manual and Command ==== ... ... @@ -1034,6 +1034,7 @@ 1034 1034 [[image:image-20230627174446-2.png]] 1035 1035 1036 1036 1039 + 1037 1037 ==== 2.6.6.3 Commands set in SDI-12-LB/LS and uplink payload ==== 1038 1038 1039 1039 ... ... @@ -1051,7 +1051,6 @@ 1051 1051 1052 1052 ==== 2.6.7.1 Reference Manual and Command ==== 1053 1053 1054 - 1055 1055 * [[https:~~/~~/static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf>>https://static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf]] 1056 1056 1057 1057 * Commands to be used in PC and output. ... ... @@ -1067,9 +1067,8 @@ 1067 1067 1068 1068 ==== 2.6.7.2 Hardware Connection to SDI-12-LB/LS ==== 1069 1069 1072 +Note: When the bytes returned by the sensor are not fixed, the full byte interception can be used: AT+ALLDATAMOD=1 (The DATACUTx parameter needs to be cleared when using this directive, or it will not work.) 1070 1070 1071 -(% style="color:red" %)**Note: When the bytes returned by the sensor are not fixed, the full byte interception can be used: AT+ALLDATAMOD=1 (The DATACUTx parameter needs to be cleared when using this directive, or it will not work.)** 1072 - 1073 1073 [[image:image-20240423145522-2.png||height="345" width="400"]] 1074 1074 1075 1075 ... ... @@ -1381,7 +1381,6 @@ 1381 1381 1382 1382 == 7.3 How to change the LoRa Frequency Bands/Region? == 1383 1383 1384 - 1385 1385 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. 1386 1386 When downloading the images, choose the required image file for download. 1387 1387 ... ... @@ -1388,7 +1388,6 @@ 1388 1388 1389 1389 == 7.4 Why is the data uploaded to the LoRaWAN platform node empty and fProt~=0? == 1390 1390 1391 - 1392 1392 This is due to The length of bytes sent by the node is limited by the lorawan protocol, and the fixed DR needs to be adjusted to improve this problem. 1393 1393 1394 1394 Please refer to the following link for the number of bytes limited by different frequencies and different DRs in the lorawan protocol ... ... @@ -1409,6 +1409,8 @@ 1409 1409 1410 1410 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]] 1411 1411 1411 +(% class="wikigeneratedid" %) 1412 += = 1412 1412 1413 1413 = 8. Order Info = 1414 1414
- image-20240823165402-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -580.7 KB - Content