Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.ting
1 +XWiki.kai
Content
... ... @@ -151,7 +151,7 @@
151 151  (% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
152 152  Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network.
153 153  )))
154 -|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means SDI-12-LB/LS is in Deep Sleep Mode.
154 +|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
155 155  
156 156  == 1.7 Pin Mapping ==
157 157  
... ... @@ -1050,27 +1050,30 @@
1050 1050  [[image:image-20230627180303-6.png||height="292" width="1171"]]
1051 1051  
1052 1052  
1053 -=== 2.6.7 Example 6 ~-~- Connect to GroPoint Profile-8 (SDI-12 Version) ===
1053 +=== 2.6.7 Example 6 ~-~- Connect to GroPoint_SDI-12 ===
1054 1054  
1055 -==== 2.6.7.1  Reference Manual and Command ====
1055 +==== 2.6.7.1Reference Manual and Command ====
1056 1056  
1057 +
1057 1057  * [[https:~~/~~/static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf>>https://static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf]]
1058 1058  
1059 1059  * Commands to be used in PC and output.
1060 1060  
1061 -1. check device address
1062 -1. change device address
1063 -1. check device ID
1064 -1. start measure
1065 -1. Get Meausre result
1062 +1.check device address
1066 1066  
1064 +2.change device address
1065 +
1066 +3.check device ID
1067 +
1068 +4.start measure
1069 +
1070 +5.Get Meausre result
1071 +
1067 1067  [[image:image-20240423143921-1.png]]
1068 1068  
1069 1069  
1070 1070  ==== 2.6.7.2 Hardware Connection to SDI-12-LB/LS ====
1071 1071  
1072 -Note: When the bytes returned by the sensor are not fixed, the full byte interception can be used: AT+ALLDATAMOD=1 (The DATACUTx parameter needs to be cleared when using this directive, or it will not work.)
1073 -
1074 1074  [[image:image-20240423145522-2.png||height="345" width="400"]]
1075 1075  
1076 1076  
... ... @@ -1382,34 +1382,11 @@
1382 1382  
1383 1383  == 7.3 How to change the LoRa Frequency Bands/Region? ==
1384 1384  
1388 +
1385 1385  You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]].
1386 1386  When downloading the images, choose the required image file for download. ​
1387 1387  
1388 1388  
1389 -== 7.4 Why is the data uploaded to the LoRaWAN platform node empty and fProt~=0? ==
1390 -
1391 -This is due to The length of bytes sent by the node is limited by the lorawan protocol, and the fixed DR needs to be adjusted to improve this problem.
1392 -
1393 -Please refer to the following link for the number of bytes limited by different frequencies and different DRs in the lorawan protocol
1394 -
1395 -[[lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf>>url:https://lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf]]
1396 -
1397 -Example:
1398 -
1399 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20240620145456-1.png?rev=1.1||alt="image-20240620145456-1.png"]]
1400 -
1401 -Please refer to the following command to fix DR
1402 -
1403 -AT+ADR=0
1404 -
1405 -AT+DR=3
1406 -
1407 -Downlink command:
1408 -
1409 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]]
1410 -
1411 -= =
1412 -
1413 1413  = 8. ​Order Info =
1414 1414  