<
From version < 102.1 >
edited by Mengting Qiu
on 2024/07/31 08:53
To version < 100.1 >
edited by kai
on 2024/05/25 10:43
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.ting
1 +XWiki.kai
Content
... ... @@ -151,7 +151,7 @@
151 151  (% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
152 152  Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network.
153 153  )))
154 -|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means SDI-12-LB/LS is in Deep Sleep Mode.
154 +|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
155 155  
156 156  == 1.7 Pin Mapping ==
157 157  
... ... @@ -1382,34 +1382,11 @@
1382 1382  
1383 1383  == 7.3 How to change the LoRa Frequency Bands/Region? ==
1384 1384  
1385 +
1385 1385  You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]].
1386 1386  When downloading the images, choose the required image file for download. ​
1387 1387  
1388 1388  
1389 -== 7.4 Why is the data uploaded to the LoRaWAN platform node empty and fProt~=0? ==
1390 -
1391 -This is due to The length of bytes sent by the node is limited by the lorawan protocol, and the fixed DR needs to be adjusted to improve this problem.
1392 -
1393 -Please refer to the following link for the number of bytes limited by different frequencies and different DRs in the lorawan protocol
1394 -
1395 -[[lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf>>url:https://lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf]]
1396 -
1397 -Example:
1398 -
1399 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20240620145456-1.png?rev=1.1||alt="image-20240620145456-1.png"]]
1400 -
1401 -Please refer to the following command to fix DR
1402 -
1403 -AT+ADR=0
1404 -
1405 -AT+DR=3
1406 -
1407 -Downlink command:
1408 -
1409 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]]
1410 -
1411 -= =
1412 -
1413 1413  = 8. ​Order Info =
1414 1414  
1415 1415  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0