Last modified by Mengting Qiu on 2025/07/03 15:42

From version 101.1
edited by Bei Jinggeng
on 2024/07/29 17:48
Change comment: There is no comment for this version
To version 90.11
edited by Xiaoling
on 2024/01/15 09:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -1,7 +1,7 @@
1 1  
2 2  
3 3  (% style="text-align:center" %)
4 -[[image:image-20240103165259-3.png||height="433" width="591"]]
4 +[[image:image-20240103165259-3.png]]
5 5  
6 6  
7 7  
... ... @@ -140,8 +140,8 @@
140 140  
141 141  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LB_Waterproof_RS485UART_to_LoRaWAN_Converter/WebHome/image-20240103160425-4.png?rev=1.1||alt="image-20240103160425-4.png"]]
142 142  
143 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
144 -|=(% style="width: 167px;background-color:#4F81BD;color:white" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 226px;background-color:#4F81BD;color:white" %)**Action**
143 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
144 +|=(% style="width: 167px;background-color:#4F81BD;color:white" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 225px;background-color:#4F81BD;color:white" %)**Action**
145 145  |(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Send an uplink|(% style="background-color:#f2f2f2; width:225px" %)(((
146 146  If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once.
147 147  Meanwhile, BLE module will be active and user can connect via BLE to configure device.
... ... @@ -526,8 +526,8 @@
526 526  For example, if return from AT+COMMAND1 is “013METER   TER12 112T12-00024895<CR><LF>” , Below AT+DATACUT1 will get different result to combine payload:
527 527  
528 528  
529 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
530 -|=(% style="width: 164px;background-color:#4F81BD;color:white" %)**AT+DATACUT1 value**|=(% style="width: 346px;background-color:#4F81BD;color:white" %)**Final Result to combine Payload**
529 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
530 +|=(% style="width: 164px;background-color:#4F81BD;color:white" %)**AT+DATACUT1 value**|=(% style="width: 344px;background-color:#4F81BD;color:white" %)**Final Result to combine Payload**
531 531  |(% style="background-color:#f2f2f2; width:164px" %)34,1,1+2+3|(% style="background-color:#f2f2f2; width:344px" %)0D 00 01 30 31 33
532 532  |(% style="background-color:#f2f2f2; width:164px" %)34,2,1~~8+12~~16|(% style="background-color:#f2f2f2; width:344px" %)0D 00 01 30 31 33 4D 45 54 45 52 54 45 52 31 32
533 533  |(% style="background-color:#f2f2f2; width:164px" %)34,2,1~~34|(% style="background-color:#f2f2f2; width:344px" %)0D 00 01 30 31 33 4D 45 54 45 52 20 20 20 54 45 52 31 32 20 31 31 32 54 31 32 2D 30 30 30 32 34 38 39 35 0D 0A
... ... @@ -647,7 +647,7 @@
647 647  
648 648  Users can also use the downlink command(0x26 01) to ask SDI-12-LB/LS to resend this uplink.
649 649  
650 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
650 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
651 651  |(% colspan="6" style="background-color:#4f81bd; color:white" %)**Device Status (FPORT=5)**
652 652  |(% style="background-color:#f2f2f2; width:103px" %)**Size (bytes)**|(% style="background-color:#f2f2f2; width:72px" %)**1**|(% style="background-color:#f2f2f2" %)**2**|(% style="background-color:#f2f2f2; width:91px" %)**1**|(% style="background-color:#f2f2f2; width:86px" %)**1**|(% style="background-color:#f2f2f2; width:44px" %)**2**
653 653  |(% style="background-color:#f2f2f2; width:103px" %)**Value**|(% style="background-color:#f2f2f2; width:72px" %)Sensor Model|(% style="background-color:#f2f2f2" %)Firmware Version|(% style="background-color:#f2f2f2; width:91px" %)Frequency Band|(% style="background-color:#f2f2f2; width:86px" %)Sub-band|(% style="background-color:#f2f2f2; width:44px" %)BAT
... ... @@ -719,7 +719,7 @@
719 719  
720 720  * Periodically Uplink: FPORT=2
721 721  
722 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:500px" %)
722 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
723 723  |=(% style="width: 90px;background-color:#4F81BD;color:white" %)(((
724 724  **Size(bytes)**
725 725  )))|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**2**|=(% style="width: 90px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 240px;background-color:#4F81BD;color:white" %)**Length depends on the return from the commands**
... ... @@ -829,27 +829,27 @@
829 829  (% style="color:#037691" %)**AT+COMMANDx=4M!,1,1,1**
830 830  
831 831  
832 -(% style="color:blue" %)**2) The AT+DATACUTx command is applied to the green arrow part, receiving and cut out data from the SDI12 sensor:**
832 +(% style="color:blue" %)**2) The AT+DATACUTx command is applied to the green arrow part, receiving and cut out data from the SDI12 sensor**
833 833  
834 834  a. The first reply, all 34 characters: ”113TRUEBNERSMT100038220303182331<CR><LF>”
835 835  
836 836  Cut out all characters: (% _mstmutation="1" style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=34,2,1~~34**(% style="color:#037691" %);
837 837  
838 -b. The sixth reply, all 31 characters: "1+19210+1.04+0.00+22.49+11.75<CR><LF>"
838 +b. The sixth reply, all 31 characters:”1+19210+1.04+0.00+22.49+11.75<CR><LF>
839 839  
840 840  Cut out all characters: (% _mstmutation="1" style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31**(% style="color:#037691" %);
841 841  
842 -c. The eighth reply, all 31 characters: "2+18990+1.08+0.00+22.24+11.80<CR><LF>"
842 +c. The eighth reply, all 31 characters:”2+18990+1.08+0.00+22.24+11.80<CR><LF>
843 843  
844 844  Cut out all characters: (% _mstmutation="1" style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=31,2,1~~31**(% style="color:#037691" %);
845 845  
846 -d. The tenth reply, all 15 characters: "3-2919.8+24.0<CR><LF>"
846 +d. The tenth reply, all 15 characters:”3-2919.8+24.0<CR><LF>
847 847  
848 848  Cut out all characters: (% _mstmutation="1" style="color:#037691" %)**AT+ALLDATAMOD=1 or AT+DATACUTx=15,2,1~~15**(% style="color:#037691" %);
849 849  
850 -e. The twelfth reply, all 25 characters: "4+30.8+22.84+4.7+954.38<CR><LF>"
850 +e. The twelfth reply, all 25 characters:”4+30.8+22.84+4.7+954.38<CR><LF>
851 851  
852 -Partial cut, the cut sensor address and the first two parameters:(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field "4+30.8+22.84"**.
852 +Partial cut, the cut sensor address and the first two parameters(% style="color:#037691" %)**AT+DATACUTx=25,2,1~~12, cut out the character field ” 4+30.8+22.84**.
853 853  
854 854  
855 855  === 2.6.2 Example 2 ~-~- Connect to Hygrovue10 ===
... ... @@ -1050,43 +1050,6 @@
1050 1050  [[image:image-20230627180303-6.png||height="292" width="1171"]]
1051 1051  
1052 1052  
1053 -=== 2.6.7 Example 6 ~-~- Connect to GroPoint Profile-8 (SDI-12 Version) ===
1054 -
1055 -==== 2.6.7.1  Reference Manual and Command ====
1056 -
1057 -* [[https:~~/~~/static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf>>https://static1.squarespace.com/static/5db0b690c4990258f8f6d042/t/64189e1ab3ebc54e6947b0c0/1679334941034/2625-N-T+GroPoint+Profile+User+Manual-V1.1.3.pdf]]
1058 -
1059 -* Commands to be used in PC and output.
1060 -
1061 -1. check device address
1062 -1. change device address
1063 -1. check device ID
1064 -1. start measure
1065 -1. Get Meausre result
1066 -
1067 -[[image:image-20240423143921-1.png]]
1068 -
1069 -
1070 -==== 2.6.7.2 Hardware Connection to SDI-12-LB/LS ====
1071 -
1072 -Note: When the bytes returned by the sensor are not fixed, the full byte interception can be used: AT+ALLDATAMOD=1 (The DATACUTx parameter needs to be cleared when using this directive, or it will not work.)
1073 -
1074 -[[image:image-20240423145522-2.png||height="345" width="400"]]
1075 -
1076 -
1077 -==== 2.6.7.3 Commands set in SDI-12-LB/LS and uplink payload ====
1078 -
1079 -[[image:image-20240423151202-3.png]]
1080 -
1081 -(% class="wikigeneratedid" id="H" %)
1082 -[[image:image-20240423162851-6.png||height="251" width="935"]]
1083 -
1084 -
1085 -DATA in TTN:
1086 -
1087 -[[image:image-20240423162322-4.png||height="269" width="933"]]
1088 -
1089 -
1090 1090  == 2.7 Frequency Plans ==
1091 1091  
1092 1092  
... ... @@ -1137,7 +1137,7 @@
1137 1137  
1138 1138  (% style="color:blue" %)**AT Command: AT+TDC**
1139 1139  
1140 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
1103 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1141 1141  |=(% style="width: 160px; background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 160px; background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 190px;background-color:#4F81BD;color:white" %)**Response**
1142 1142  |(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=?|(% style="background-color:#f2f2f2; width:166px" %)Show current transmit Interval|(% style="background-color:#f2f2f2" %)(((
1143 1143  30000
... ... @@ -1165,7 +1165,7 @@
1165 1165  
1166 1166  (% style="color:blue" %)**AT Command: AT+INTMOD**
1167 1167  
1168 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
1131 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1169 1169  |=(% style="width: 154px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 196px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 160px;background-color:#4F81BD;color:white" %)**Response**
1170 1170  |(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=?|(% style="background-color:#f2f2f2; width:196px" %)Show current interrupt mode|(% style="background-color:#f2f2f2; width:157px" %)(((
1171 1171  0
... ... @@ -1196,7 +1196,7 @@
1196 1196  
1197 1197  (% style="color:blue" %)**AT Command: AT+3V3T**
1198 1198  
1199 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:474px" %)
1162 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:474px" %)
1200 1200  |=(% style="width: 154px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 201px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 120px;background-color:#4F81BD;color:white" %)**Response**
1201 1201  |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=?|(% style="background-color:#f2f2f2; width:201px" %)Show 3V3 open time.|(% style="background-color:#f2f2f2; width:116px" %)(((
1202 1202  0
... ... @@ -1267,7 +1267,7 @@
1267 1267  
1268 1268  (% style="color:blue" %)**AT Command: AT+ALLDATAMOD**
1269 1269  
1270 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:437px" %)
1233 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:437px" %)
1271 1271  |=(% style="background-color:#4F81BD;color:white" %)**Command Example**|=(% style="background-color:#4F81BD;color:white" %)**Function**|=(% style="background-color:#4F81BD;color:white" %)**Response**
1272 1272  |(% style="background-color:#f2f2f2" %)AT+ALLDATAMOD=?|(% style="background-color:#f2f2f2" %)Show current all data mode|(% style="background-color:#f2f2f2" %)(((
1273 1273  0
... ... @@ -1289,7 +1289,7 @@
1289 1289  
1290 1290  (% style="color:blue" %)**AT Command: AT+DATAUP**
1291 1291  
1292 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
1255 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1293 1293  |=(% style="width: 154px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 266px;background-color:#4F81BD;color:white" %)**Function**|=(% style="background-color:#4F81BD;color:white" %)**Response**
1294 1294  |(% style="background-color:#f2f2f2; width:154px" %)AT+DATAUP =?|(% style="background-color:#f2f2f2; width:266px" %)Show current splicing payload for uplink mode|(% style="background-color:#f2f2f2" %)(((
1295 1295  0
... ... @@ -1323,7 +1323,7 @@
1323 1323  
1324 1324  (% style="color:blue" %)**AT Command: AT+PAYVER**
1325 1325  
1326 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:437px" %)
1289 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:437px" %)
1327 1327  |=(% style="width: 158px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 192px;background-color:#4F81BD;color:white" %)**Function**|=(% style="background-color:#4F81BD;color:white" %)**Response**
1328 1328  |(% style="background-color:#f2f2f2; width:158px" %)AT+PAYVER=?|(% style="background-color:#f2f2f2; width:192px" %)Show current payload version|(% style="background-color:#f2f2f2" %)(((
1329 1329  1
... ... @@ -1382,35 +1382,11 @@
1382 1382  
1383 1383  == 7.3 How to change the LoRa Frequency Bands/Region? ==
1384 1384  
1348 +
1385 1385  You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]].
1386 1386  When downloading the images, choose the required image file for download. ​
1387 1387  
1388 1388  
1389 -== 7.4 Why is the data uploaded to the LoRaWAN platform node empty and fProt~=0? ==
1390 -
1391 -This is due to The length of bytes sent by the node is limited by the lorawan protocol, and the fixed DR needs to be adjusted to improve this problem.
1392 -
1393 -Please refer to the following link for the number of bytes limited by different frequencies and different DRs in the lorawan protocol
1394 -
1395 -[[lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf>>url:https://lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf]]
1396 -
1397 -Example:
1398 -
1399 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20240620145456-1.png?rev=1.1||alt="image-20240620145456-1.png"]]
1400 -
1401 -Please refer to the following command to fix DR
1402 -
1403 -AT+ADR=0
1404 -
1405 -AT+DR=3
1406 -
1407 -Downlink command:
1408 -
1409 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]]
1410 -
1411 -(% class="wikigeneratedid" %)
1412 -= =
1413 -
1414 1414  = 8. ​Order Info =
1415 1415  
1416 1416  
... ... @@ -1438,6 +1438,7 @@
1438 1438  * M12: M12 hole
1439 1439  * M16: M16 hole
1440 1440  
1380 +
1441 1441  = 9. Packing Info =
1442 1442  
1443 1443  
... ... @@ -1452,6 +1452,7 @@
1452 1452  * Package Size / pcs : cm
1453 1453  * Weight / pcs : g
1454 1454  
1395 +
1455 1455  = 10. ​Support =
1456 1456  
1457 1457  
image-20240423143921-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.kai
Size
... ... @@ -1,1 +1,0 @@
1 -43.8 KB
Content
image-20240423145522-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.kai
Size
... ... @@ -1,1 +1,0 @@
1 -709.9 KB
Content
image-20240423151202-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.kai
Size
... ... @@ -1,1 +1,0 @@
1 -45.6 KB
Content
image-20240423162322-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.kai
Size
... ... @@ -1,1 +1,0 @@
1 -87.5 KB
Content
image-20240423162811-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.kai
Size
... ... @@ -1,1 +1,0 @@
1 -45.6 KB
Content
image-20240423162851-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.kai
Size
... ... @@ -1,1 +1,0 @@
1 -45.6 KB
Content