Summary

Details

Page properties
Content
... ... @@ -410,7 +410,7 @@
410 410  === 2.5.1 Ways to get datalog via LoRaWAN ===
411 411  
412 412  
413 -Set PNACKMD=1, S31x-LB/LS will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB/LS will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
413 +Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB/LS will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB/LS will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
414 414  
415 415  * (((
416 416  a) S31x-LB/LS will do an ACK check for data records sending to make sure every data arrive server.
... ... @@ -419,7 +419,11 @@
419 419  b) S31x-LB/LS will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB/LS won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB/LS gets a ACK, S31x-LB/LS will consider there is a network connection and resend all NONE-ACK messages.
420 420  )))
421 421  
422 +Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
422 422  
424 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220703111700-2.png?width=1119&height=381&rev=1.1||alt="图片-20220703111700-2.png" height="381" width="1119"]]
425 +
426 +
423 423  === 2.5.2 Unix TimeStamp ===
424 424  
425 425  
... ... @@ -464,6 +464,10 @@
464 464  (((
465 465  Humidity
466 466  )))
471 +
472 +(((
473 +
474 +)))
467 467  )))|(% style="width:87px" %)(((
468 468  Temperature
469 469  )))|(% style="width:178px" %)(((
... ... @@ -557,7 +557,7 @@
557 557  == 2.7 Frequency Plans ==
558 558  
559 559  
560 -The S31x-LB/LS uses OTAA mode and below frequency plans by default. Each frequency band use different firmware, user update the firmware to the corresponding band for their country.
568 +The S31x-LB/LS uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
561 561  
562 562  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]