... ... @@ -51,7 +51,7 @@
51 51  * Support wireless OTA update firmware
52 52  * Uplink on periodically
53 53  * Downlink to change configure
54 -* 88500mAh Li/SOCl2 Battery (S31/S31B-LB)
54 +* 8500mAh Li/SOCl2 Battery (S31/S31B-LB)
55 55  * Solar panel + 3000mAh Li-on battery (S31/S31B-LS)
56 56  
57 57  == 1.3 Specification ==
... ... @@ -109,8 +109,8 @@
109 109  
110 110  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LB_Waterproof_RS485UART_to_LoRaWAN_Converter/WebHome/image-20240103160425-4.png?rev=1.1||alt="image-20240103160425-4.png"]]
111 111  
112 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
113 -|=(% style="width: 167px;background-color:#4F81BD;color:white" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 225px;background-color:#4F81BD;color:white" %)**Action**
112 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
113 +|=(% style="width: 167px;background-color:#4F81BD;color:white" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 226px;background-color:#4F81BD;color:white" %)**Action**
114 114  |(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)(((
115 115  If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once.
116 116  Meanwhile, BLE module will be active and user can connect via BLE to configure device.
... ... @@ -145,7 +145,7 @@
145 145  == 1.8 Hardware Variant ==
146 146  
147 147  
148 -(% border="1" cellspacing="5" style="width:461.818px" %)
148 +(% border="1" cellspacing="3" style="width:460px" %)
149 149  |=(% style="width: 102px;background-color:#4F81BD;color:white" %)Model|=(% style="width: 182px; background-color:#4F81BD;color:white" %)Photo|=(% style="width: 176px; background-color:#4F81BD;color:white" %)Probe Info
150 150  |(% style="width:102px" %)(((
151 151  S31-LB/LS
... ... @@ -260,7 +260,7 @@
260 260  The Payload format is as below.
261 261  
262 262  
263 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
263 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
264 264  |(% colspan="6" style="background-color:#4f81bd; color:white" %)**Device Status (FPORT=5)**
265 265  |(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2**
266 266  |(% style="width:103px" %)Value|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT
... ... @@ -328,7 +328,7 @@
328 328  
329 329  Sensor Data is uplink via FPORT=2
330 330  
331 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
331 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:500px" %)
332 332  |=(% style="width: 60px;background-color:#4F81BD;color:white" %)(((
333 333  **Size(bytes)**
334 334  )))|=(% style="width: 40px;background-color:#4F81BD;color:white" %)2|=(% style="width: 90px;background-color:#4F81BD;color:white" %)4|=(% style="width: 150px; background-color: #4F81BD;color:white" %)1|=(% style="width: 80px; background-color: #4F81BD;color:white" %)**2**|=(% style="width: 80px; background-color: #4F81BD;color:white" %)2
... ... @@ -419,7 +419,6 @@
419 419  b) S31x-LB/LS will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB/LS won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB/LS gets a ACK, S31x-LB/LS will consider there is a network connection and resend all NONE-ACK messages.
420 420  )))
421 421  
422 -
423 423  === 2.5.2 Unix TimeStamp ===
424 424  
425 425  
... ... @@ -454,7 +454,7 @@
454 454  
455 455  **Retrieval data payload:**
456 456  
457 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
456 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:500px" %)
458 458  |=(% style="width: 60px;background-color:#4F81BD;color:white" %)(((
459 459  **Size(bytes)**
460 460  )))|=(% style="width: 40px; background-color:#4F81BD;color:white" %)**2**|=(% style="width: 55px; background-color:#4F81BD;color:white" %)**2**|=(% style="width: 65px; background-color:#4F81BD;color:white" %)**2**|=(% style="width: 180px; background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px; background-color:#4F81BD;color:white" %)**4**
... ... @@ -605,7 +605,7 @@
605 605  
606 606  (% style="color:blue" %)**AT Command: AT+TDC**
607 607  
608 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
607 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
609 609  |=(% style="width: 156px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 137px;background-color:#4F81BD;color:white" %)**Function**|=(% style="background-color:#4F81BD;color:white" %)**Response**
610 610  |(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
611 611  30000
... ... @@ -718,7 +718,7 @@
718 718  
719 719  (% style="color:blue" %)**AT Command: AT+INTMOD**
720 720  
721 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
720 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
722 722  |=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 197px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 158px;background-color:#4F81BD;color:white" %)**Response**
723 723  |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
724 724  0
... ... @@ -755,7 +755,7 @@
755 755  
756 756  (% style="color:blue" %)**AT Command: AT+5VT**
757 757  
758 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
757 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
759 759  |=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 197px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 158px;background-color:#4F81BD;color:white" %)**Response**
760 760  |(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default)
761 761  OK