Last modified by Mengting Qiu on 2025/07/01 15:58

From version 74.1
edited by Xiaoling
on 2024/01/04 16:52
Change comment: Uploaded new attachment "image-20240104165223-7.png", version {1}
To version 73.3
edited by Xiaoling
on 2024/01/04 16:30
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -51,8 +51,7 @@
51 51  * Support wireless OTA update firmware
52 52  * Uplink on periodically
53 53  * Downlink to change configure
54 -* 88500mAh Li/SOCl2 Battery (S31/S31B-LB)
55 -* Solar panel + 3000mAh Li-on battery (S31/S31B-LS)
54 +* 8500mAh Battery for long term use
56 56  
57 57  == 1.3 Specification ==
58 58  
... ... @@ -59,7 +59,7 @@
59 59  
60 60  (% style="color:#037691" %)**Common DC Characteristics:**
61 61  
62 -* Supply Voltage: Built-in Battery , 2.5v ~~ 3.6v
61 +* Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v
63 63  * Operating Temperature: -40 ~~ 85°C
64 64  
65 65  (% style="color:#037691" %)**Temperature Sensor:**
... ... @@ -107,8 +107,9 @@
107 107  == 1.5 Button & LEDs ==
108 108  
109 109  
110 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LB_Waterproof_RS485UART_to_LoRaWAN_Converter/WebHome/image-20240103160425-4.png?rev=1.1||alt="image-20240103160425-4.png"]]
109 +[[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]]
111 111  
111 +
112 112  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
113 113  |=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action**
114 114  |(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)(((
... ... @@ -125,7 +125,7 @@
125 125  == 1.6 BLE connection ==
126 126  
127 127  
128 -S31x-LB/LS support BLE remote configure.
128 +S31x-LB support BLE remote configure.
129 129  
130 130  
131 131  BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
... ... @@ -148,7 +148,7 @@
148 148  (% border="1" cellspacing="5" style="width:461.818px" %)
149 149  |=(% style="width: 102px;background-color:#D9E2F3;color:#0070C0" %)Model|=(% style="width: 182px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)Photo|=(% style="width: 176px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)Probe Info
150 150  |(% style="width:102px" %)(((
151 -S31-LB/LS
151 +S31-LB
152 152  )))|(% style="width:182px" %)[[image:image-20230527093214-2.jpeg]]|(% style="width:176px" %)(((
153 153  1 x SHT31 Probe
154 154  
... ... @@ -157,7 +157,7 @@
157 157  
158 158  )))
159 159  |(% style="width:102px" %)(((
160 -S31B-LB/LS
160 +S31B-LB
161 161  )))|(% style="width:182px" %)[[image:image-20230527093155-1.jpeg]]|(% style="width:176px" %)(((
162 162  1 x SHT31 Probe
163 163  
... ... @@ -170,7 +170,6 @@
170 170  
171 171  == 1.9 Mechanical ==
172 172  
173 -=== 1.9.1 for LB version ===
174 174  
175 175  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143884058-338.png]]
176 176  
... ... @@ -181,18 +181,12 @@
181 181  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]]
182 182  
183 183  
184 -=== 1.9.2 for LS version ===
183 += 2. Configure S31x-LB to connect to LoRaWAN network =
185 185  
186 -
187 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SN50v3-LB/WebHome/image-20231231203439-3.png?width=886&height=385&rev=1.1||alt="image-20231231203439-3.png"]]
188 -
189 -
190 -= 2. Configure S31x-LB/LS to connect to LoRaWAN network =
191 -
192 192  == 2.1 How it works ==
193 193  
194 194  
195 -The S31x-LB/LS is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the S31x-LB/LS. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
188 +The S31x-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the S31x-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
196 196  
197 197  
198 198  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
... ... @@ -203,9 +203,9 @@
203 203  The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
204 204  
205 205  
206 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from S31x-LB/LS.
199 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from S31x-LB.
207 207  
208 -Each S31x-LB/LS is shipped with a sticker with the default device EUI as below:
201 +Each S31x-LB is shipped with a sticker with the default device EUI as below:
209 209  
210 210  [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]]
211 211  
... ... @@ -234,10 +234,10 @@
234 234  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]]
235 235  
236 236  
237 -(% style="color:blue" %)**Step 2:**(%%) Activate on S31x-LB/LS
230 +(% style="color:blue" %)**Step 2:**(%%) Activate on S31x-LB
238 238  
239 239  
240 -Press the button for 5 seconds to activate the S31x-LB/LS.
233 +Press the button for 5 seconds to activate the S31x-LB.
241 241  
242 242  (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
243 243  
... ... @@ -249,7 +249,7 @@
249 249  === 2.3.1 Device Status, FPORT~=5 ===
250 250  
251 251  
252 -Users can use the downlink command(**0x26 01**) to ask S31x-LB/LS to send device configure detail, include device configure status. S31x-LB/LS will uplink a payload via FPort=5 to server.
245 +Users can use the downlink command(**0x26 01**) to ask S31x-LB to send device configure detail, include device configure status. S31x-LB will uplink a payload via FPort=5 to server.
253 253  
254 254  The Payload format is as below.
255 255  
... ... @@ -264,7 +264,7 @@
264 264  [[image:image-20230524144422-1.png||height="174" width="1080"]]
265 265  
266 266  
267 -(% style="color:#037691" %)**Sensor Model**(%%): For S31x-LB/LS, this value is 0x0A
260 +(% style="color:#037691" %)**Sensor Model**(%%): For S31x-LB, this value is 0x0A
268 268  
269 269  (% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
270 270  
... ... @@ -398,19 +398,19 @@
398 398  == 2.5 Datalog Feature ==
399 399  
400 400  
401 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB/LS will store the reading for future retrieving purposes.
394 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes.
402 402  
403 403  
404 404  === 2.5.1 Ways to get datalog via LoRaWAN ===
405 405  
406 406  
407 -Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB/LS will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB/LS will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
400 +Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
408 408  
409 409  * (((
410 -a) S31x-LB/LS will do an ACK check for data records sending to make sure every data arrive server.
403 +a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server.
411 411  )))
412 412  * (((
413 -b) S31x-LB/LS will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB/LS won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB/LS gets a ACK, S31x-LB/LS will consider there is a network connection and resend all NONE-ACK messages.
406 +b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages.
414 414  )))
415 415  
416 416  Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
... ... @@ -421,7 +421,7 @@
421 421  === 2.5.2 Unix TimeStamp ===
422 422  
423 423  
424 -S31x-LB/LS uses Unix TimeStamp format based on
417 +S31x-LB uses Unix TimeStamp format based on
425 425  
426 426  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]]
427 427  
... ... @@ -440,7 +440,7 @@
440 440  
441 441  User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command.
442 442  
443 -Once S31x-LB/LS Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB/LS. If S31x-LB/LS fails to get the time from the server, S31x-LB/LS will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
436 +Once S31x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
444 444  
445 445  (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
446 446  
... ... @@ -499,7 +499,7 @@
499 499  
500 500  **Example:**
501 501  
502 -If S31x-LB/LS has below data inside Flash:
495 +If S31x-LB has below data inside Flash:
503 503  
504 504  [[image:image-20230524114654-2.png]]
505 505  
... ... @@ -511,7 +511,7 @@
511 511   Stop time: 646D856C= time 23/5/24 03:33:00
512 512  
513 513  
514 -**S31x-LB/LS will uplink this payload.**
507 +**S31x-LB will uplink this payload.**
515 515  
516 516  [[image:image-20230524114826-3.png||height="448" width="1244"]]
517 517  
... ... @@ -549,7 +549,7 @@
549 549  == 2.6 Temperature Alarm Feature ==
550 550  
551 551  
552 -S31x-LB/LS work flow with Alarm feature.
545 +S31x-LB work flow with Alarm feature.
553 553  
554 554  
555 555  [[image:image-20230524110125-3.png||height="768" width="1115"]]
... ... @@ -559,7 +559,7 @@
559 559  == 2.7 Frequency Plans ==
560 560  
561 561  
562 -The S31x-LB/LS uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
555 +The S31x-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
563 563  
564 564  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
565 565  
... ... @@ -570,12 +570,12 @@
570 570  **Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/fis3g6nmhv0eokg/AAC6BcCZaX4BdqZkduUvZ3jIa?dl=0>>https://www.dropbox.com/sh/fis3g6nmhv0eokg/AAC6BcCZaX4BdqZkduUvZ3jIa?dl=0]]
571 571  
572 572  
573 -= 3. Configure S31x-LB/LS =
566 += 3. Configure S31x-LB =
574 574  
575 575  == 3.1 Configure Methods ==
576 576  
577 577  
578 -S31x-LB/LS supports below configure method:
571 +S31x-LB supports below configure method:
579 579  
580 580  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
581 581  * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
... ... @@ -594,10 +594,10 @@
594 594  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
595 595  
596 596  
597 -== 3.3 Commands special design for S31x-LB/LS ==
590 +== 3.3 Commands special design for S31x-LB ==
598 598  
599 599  
600 -These commands only valid for S31x-LB/LS, as below:
593 +These commands only valid for S31x-LB, as below:
601 601  
602 602  
603 603  === 3.3.1 Set Transmit Interval Time ===
... ... @@ -775,7 +775,7 @@
775 775  = 4. Battery & Power Consumption =
776 776  
777 777  
778 -S31x-LB use ER26500 + SPC1520 battery pack and S31x-LS use 3000mAh Recharable Battery with Solar Panel. See below link for detail information about the battery info and how to replace.
771 +S31x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
779 779  
780 780  [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
781 781  
... ... @@ -784,7 +784,7 @@
784 784  
785 785  
786 786  (% class="wikigeneratedid" %)
787 -User can change firmware S31x-LB/LS to:
780 +User can change firmware S31x-LB to:
788 788  
789 789  * Change Frequency band/ region.
790 790  * Update with new features.
... ... @@ -805,7 +805,7 @@
805 805  = 7. Order Info =
806 806  
807 807  
808 -Part Number: (% style="color:blue" %)**S31-LB-XX / S31B-LB-XX**(%%)**  or  (% style="color:blue" %)S31-LS-XX / S31B-LS-XX(%%)**
801 +Part Number: (% style="color:blue" %)**S31-LB-XX  / S31B-LB-XX**
809 809  
810 810  (% style="color:red" %)**XX**(%%): The default frequency band
811 811  
... ... @@ -830,7 +830,7 @@
830 830  
831 831  (% style="color:#037691" %)**Package Includes**:
832 832  
833 -* S31x-LB or S31x-LS LoRaWAN Temperature & Humidity Sensor
826 +* S31x-LB LoRaWAN Temperature & Humidity Sensor
834 834  
835 835  (% style="color:#037691" %)**Dimension and weight**:
836 836  
image-20240104165223-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -30.6 KB
Content