Last modified by Xiaoling on 2025/04/16 14:39
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -319,11 +319,6 @@ 319 319 [[Humidity>>path:#HHumidity:]] 320 320 ))) 321 321 322 - 323 - 324 - 325 - 326 - 327 327 ==== (% style="color:#4472c4" %)**Battery:**(%%) ==== 328 328 329 329 Sensor Battery Level. ... ... @@ -345,13 +345,13 @@ 345 345 (FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 346 346 347 347 348 -==== **Humidity:** ==== 343 +==== (% style="color:#4472c4" %)**Humidity:**(%%) ==== 349 349 350 350 351 351 Read:0x(0197)=412 Value: 412 / 10=41.2, So 41.2% 352 352 353 353 354 -==== **Alarm Flag& MOD:** ==== 349 +==== (% style="color:#4472c4" %)**Alarm Flag& MOD:**(%%) ==== 355 355 356 356 357 357 **Example:** ... ... @@ -362,34 +362,31 @@ 362 362 363 363 If payload >> 2 = 0x00 **~-~->** means MOD=1, This is a sampling uplink message 364 364 365 -If payload >> 2 = 0x31 **~-~->** means MOD=31, this message is a reply message for polling, this message contains the alarm settings. see [[this link>>path:#HPolltheAlarmsettings:]] for detail. 360 +If payload >> 2 = 0x31 **~-~->** means MOD=31, this message is a reply message for polling, this message contains the alarm settings. see [[this link>>path:#HPolltheAlarmsettings:]] for detail. 366 366 367 367 368 368 == 2.4 Payload Decoder file == 369 369 365 +In TTN, use can add a custom payload so it shows friendly reading 370 370 371 -((( 372 -In TTN, use can add a custom payload so it shows friendly. 373 -))) 367 +In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: 374 374 375 -((( 376 -In the page **Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder** to add the decoder from: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/LSN50v2-S31%26S31B >>https://github.com/dragino/dragino-end-node-decoder/tree/main/LSN50v2-S31%26S31B]] 377 -))) 369 +[[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/LSN50v2-S31%26S31B >>https://github.com/dragino/dragino-end-node-decoder/tree/main/LSN50v2-S31%26S31B]] 378 378 379 379 380 380 == 2.5 Datalog Feature == 381 381 382 382 383 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, D2x-LB will store the reading for future retrieving purposes.375 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes. 384 384 385 385 386 386 === 2.5.1 Ways to get datalog via LoRaWAN === 387 387 388 388 389 -Set [[PNACKMD=1>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.13AutoSendNone-ACKmessages]], D2x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,D2x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.381 +Set [[PNACKMD=1>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.13AutoSendNone-ACKmessages]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 390 390 391 -* a) D2x-LB will do an ACK check for data records sending to make sure every data arrive server.392 -* b) D2x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, butD2x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink ifD2x-LB gets a ACK,D2x-LB will consider there is a network connection and resend all NONE-ACKMessage.383 +* a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server. 384 +* b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages. 393 393 394 394 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 395 395 ... ... @@ -398,7 +398,7 @@ 398 398 === 2.5.2 Unix TimeStamp === 399 399 400 400 401 -L HT65Nuses Unix TimeStamp format based on393 +S31x-LB uses Unix TimeStamp format based on 402 402 403 403 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="image-20220523001219-11.png" height="97" width="627"]] 404 404 ... ... @@ -414,17 +414,17 @@ 414 414 === 2.5.3 Set Device Time === 415 415 416 416 417 -User need to set SYNCMOD=1 to enable sync time via MAC command. 409 +User need to set **SYNCMOD=1** to enable sync time via MAC command. 418 418 419 -Once D2x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time toD2x-LB. IfD2x-LB fails to get the time from the server,D2x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).411 +Once S31x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 420 420 421 421 **Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 422 422 423 423 424 -=== 2.5.4 Datalog Uplink payload (FPORT~=3)===416 +=== 2.5.4 Datalog Uplink payload (FPORT~=3) === 425 425 426 426 427 -The Datalog poll replyuplink will use below payload format.419 +The Datalog uplinks will use below payload format. 428 428 429 429 **Retrieval data payload:** 430 430 ... ... @@ -472,7 +472,7 @@ 472 472 473 473 Stop time: 60066DA7= time 21/1/19 05:27:03 474 474 475 -**L HT65Nwill uplink this payload.**467 +**S31x-LB will uplink this payload.** 476 476 477 477 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-13.png?width=727&height=421&rev=1.1||alt="image-20220523001219-13.png" height="421" width="727"]] 478 478 ... ... @@ -498,7 +498,7 @@ 498 498 == 2.6 Temperature Alarm Feature == 499 499 500 500 501 - D2x-LB work flow with Alarm feature.493 +S31x-LB work flow with Alarm feature. 502 502 503 503 504 504 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-D20-D22-D23%20LoRaWAN%20Temperature%20Sensor%20User%20Manual/WebHome/image-20220623090437-1.png?rev=1.1||alt="image-20220623090437-1.png"]] ... ... @@ -508,7 +508,7 @@ 508 508 == 2.7 Frequency Plans == 509 509 510 510 511 -The D2x-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.503 +The S31x-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 512 512 513 513 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 514 514 ... ... @@ -518,19 +518,18 @@ 518 518 519 519 **Firmware download link:** 520 520 521 -[[https:~~/~~/www.dropbox.com/sh/ gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]513 +[[https:~~/~~/www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0>>https://www.dropbox.com/sh/kwqv57tp6pejias/AAAopYMATh1GM6fZ-VRCLrpDa?dl=0]] 522 522 523 523 516 += 3. Configure S31x-LB = 524 524 525 -= 3. Configure D2x-LB = 526 - 527 527 == 3.1 Configure Methods: == 528 528 529 529 530 - D2x-LB supports below configure method:521 +S31x-LB supports below configure method: 531 531 532 532 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 533 -* AT Command via UART Connection : See [[ FAQ>>||anchor="H7.FAQ"]].524 +* AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 534 534 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 535 535 536 536 == 3.2 General Commands == ... ... @@ -546,10 +546,10 @@ 546 546 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 547 547 548 548 549 -== 3.3 Commands special design for D2x-LB ==540 +== 3.3 Commands special design for S31x-LB == 550 550 551 551 552 -These commands only valid for D2x-LB, as below:543 +These commands only valid for S31x-LB, as below: 553 553 554 554 555 555 === 3.3.1 Set Transmit Interval Time === ... ... @@ -590,69 +590,64 @@ 590 590 Sensor will upload Device Status via FPORT=5. See payload section for detail. 591 591 592 592 593 -=== 3.3.3 Set Alarm Thre dhold ===584 +=== 3.3.3 Set Temperature Alarm Threshold: === 594 594 586 +* **AT Command:** 595 595 596 - (% style="color:#4472c4" %)**1. Set forAllProbes:**588 +**AT+SHTEMP=min,max** 597 597 598 -(% style="color:#037691" %)**AT+18ALARM=min,max** 590 +* When min=0, and max≠0, Alarm higher than max 591 +* When min≠0, and max=0, Alarm lower than min 592 +* When min≠0 and max≠0, Alarm higher than max or lower than min 599 599 600 -* When min=0, and max≠0, Alarm trigger when higher than max 601 -* When min≠0, and max=0, Alarm trigger when lower than min 602 -* When min≠0 and max≠0, Alarm trigger when higher than max or lower than min 594 +Example: 603 603 604 - **Example:**596 + AT+SHTEMP=0,30 ~/~/ Alarm when temperature higher than 30. 605 605 606 - AT+18ALARM=-10,30 ~/~/ Alarmwhen< -10 or higher than30.598 +* **Downlink Payload:** 607 607 600 +**0x(0C 01 00 1E)** ~/~/Set AT+SHTEMP=0,30 608 608 609 -* % style="color:#037691"%)**DownlinkPayload:**602 +**(note: 3^^rd^^ byte= 0x00 for low limit(not set), 4^^th^^ byte = 0x1E for high limit: 30)** 610 610 611 -0x(0B F6 1E) ~/~/ Same as AT+18ALARM=-10,30 612 612 613 - (note: 0x1E= 30,0xF6means:0xF6-0x100=-10)605 +=== 3.3.4 Set Humidity Alarm Threshold: === 614 614 607 +* **AT Command:** 615 615 616 - (% style="color:#4472c4" %)**2.Set for Separate Probe:**609 +**AT+SHHUM=min,max** 617 617 618 -(% style="color:#037691" %)**AT+18ALARM=min,max,index** 611 +* When min=0, and max≠0, Alarm higher than max 612 +* When min≠0, and max=0, Alarm lower than min 613 +* When min≠0 and max≠0, Alarm higher than max or lower than min 619 619 620 - Index:615 +Example: 621 621 622 -* 1: Temperature_Red 623 -* 2: Temperature_White 624 -* 3: Temperature_Black 617 + AT+SHHUM=70,0 ~/~/ Alarm when humidity lower than 70%. 625 625 626 -** Example:**619 +* **Downlink Payload:** 627 627 628 - AT+18ALARM=-10,30,1Alarm whentemperature_red< -10or higher than 30.621 +**0x(0C 02 46 00)** ~/~/Set AT+SHTHUM=70,0 629 629 623 +**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))** 630 630 631 -* (% style="color:#037691" %)**Downlink Payload:** 632 632 633 - 0x(0BF61E 01) ~/~/SameasAT+18ALARM=-10,30,1626 +=== 3.3.5 Set Alarm Interval: === 634 634 635 -(note: 0x1E= 30, 0xF6 means: 0xF6-0x100 = -10) 636 - 637 - 638 -=== 3.3.4 Set Alarm Interval === 639 - 640 - 641 641 The shortest time of two Alarm packet. (unit: min) 642 642 643 -* (% style="color:#037691" %)**AT Command:**630 +* **AT Command:** 644 644 645 -AT+ATDC=30 ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes. 632 +**AT+ATDC=30** ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes. 646 646 634 +* **Downlink Payload:** 647 647 648 -* %style="color:#037691"%)**DownlinkPayload:**636 +**0x(0D 00 1E)** **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes 649 649 650 -0x(0D 00 1E) **~-~-->** Set AT+ATDC=0x 00 1E = 30 minutes 651 651 639 +=== 3.3.6 Get Alarm settings (什么FPORT?) === 652 652 653 -=== 3.3.5 Get Alarm settings (什么FPORT?) === 654 654 655 - 656 656 Send a LoRaWAN downlink to ask device send Alarm settings. 657 657 658 658 * (% style="color:#037691" %)**Downlink Payload: **(%%)0x0E 01 ... ... @@ -666,9 +666,11 @@ 666 666 667 667 * Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message. 668 668 669 -=== 3.3.6 Set Interrupt Mode === 670 670 671 671 657 +=== 3.3.7 Set Interrupt Mode === 658 + 659 + 672 672 Feature, Set Interrupt mode for GPIO_EXIT. 673 673 674 674 (% style="color:blue" %)**AT Command: AT+INTMOD** ... ... @@ -697,10 +697,11 @@ 697 697 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 698 698 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 699 699 688 + 700 700 = 4. Battery & Power Consumption = 701 701 702 702 703 - D2x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.692 +S31x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 704 704 705 705 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 706 706 ... ... @@ -716,7 +716,7 @@ 716 716 == 6.1 How to use AT Command via UART to access device? == 717 717 718 718 719 -See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H 1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]708 +See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]] 720 720 721 721 722 722 == 6.2 How to update firmware via UART port? == ... ... @@ -734,7 +734,7 @@ 734 734 = 7. Order Info = 735 735 736 736 737 -Part Number: (% style="color:blue" %)** D20-LB-XX /D22-LB-XX / D23-LB-XX**726 +Part Number: (% style="color:blue" %)**S31-LB-XX / S31x-LB-XX** 738 738 739 739 (% style="color:red" %)**XX**(%%): The default frequency band 740 740 ... ... @@ -759,7 +759,7 @@ 759 759 760 760 (% style="color:#037691" %)**Package Includes**: 761 761 762 -* D2x-LB LoRaWAN Temperature Sensor751 +* S31x-LB LoRaWAN Temperature & Humidity Sensor 763 763 764 764 (% style="color:#037691" %)**Dimension and weight**: 765 765