Last modified by Mengting Qiu on 2025/07/01 15:58

From version 69.1
edited by Xiaoling
on 2024/01/04 16:15
Change comment: Uploaded new attachment "image-20240104161535-2.png", version {1}
To version 73.5
edited by Xiaoling
on 2024/01/04 16:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,9 +1,14 @@
1 + (% style="display:none" %) (%%) (% style="display:none" %) (%%) (% style="display:none" %)
2 +
1 1  (% style="text-align:center" %)
2 -[[image:S31-B.jpg]]
4 +[[image:image-20240104162316-6.png]]
3 3  
4 4  
5 5  
6 6  
9 +
10 +
11 +
7 7  **Table of Contents:**
8 8  
9 9  {{toc/}}
... ... @@ -15,22 +15,22 @@
15 15  
16 16  = 1. Introduction =
17 17  
18 -== 1.1 What is S31x-LB LoRaWAN Temperature & Humidity Sensor ==
23 +== 1.1 What is S31x-LB/LS LoRaWAN Temperature & Humidity Sensor ==
19 19  
20 20  
21 -The Dragino S31x-LB is a (% style="color:blue" %)**LoRaWAN Temperature and Humidity Sensor**(%%) for Internet of Things solution. It is used to measure the (% style="color:blue" %)**surrounding environment temperature and relative air humidity precisely**(%%), and then upload to IoT server via LoRaWAN wireless protocol.
26 +The Dragino S31x-LB/LS is a (% style="color:blue" %)**LoRaWAN Temperature and Humidity Sensor**(%%) for Internet of Things solution. It is used to measure the (% style="color:blue" %)**surrounding environment temperature and relative air humidity precisely**(%%), and then upload to IoT server via LoRaWAN wireless protocol.
22 22  
23 -The temperature & humidity sensor used in S31x-LB is SHT31, which is fully calibrated, linearized, and temperature compensated digital output from Sensirion, it provides a strong reliability and long-term stability. The SHT31 is fixed in a (% style="color:blue" %)**waterproof anti-condensation casing**(%%) for long term use.
28 +The temperature & humidity sensor used in S31x-LB/LS is SHT31, which is fully calibrated, linearized, and temperature compensated digital output from Sensirion, it provides a strong reliability and long-term stability. The SHT31 is fixed in a (% style="color:blue" %)**waterproof anti-condensation casing**(%%) for long term use.
24 24  
25 -The LoRa wireless technology used in S31x-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
30 +The LoRa wireless technology used in S31x-LB/LS allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
26 26  
27 -S31x-LB supports (% style="color:blue" %)**Temperature & Humdity alarm feature**(%%), user can set temperature alarm for instant notice. S31x-LB supports Datalog feature, it can save the data when there is no LoRaWAN network and uplink when network recover.
32 +S31x-LB/LS supports (% style="color:blue" %)**Temperature & Humdity alarm feature**(%%), user can set temperature alarm for instant notice. S31x-LB/LS supports Datalog feature, it can save the data when there is no LoRaWAN network and uplink when network recover.
28 28  
29 -S31x-LB (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
34 +S31x-LB/LS (% style="color:blue" %)**supports BLE configure**(%%) and (% style="color:blue" %)**wireless OTA update**(%%) which make user easy to use.
30 30  
31 -S31x-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
36 +S31x-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%) or (% style="color:blue" %)**solar powered + li-on battery**(%%) it is designed for long term use up to 5 years.
32 32  
33 -Each S31x-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
38 +Each S31x-LB/LS is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
34 34  
35 35  
36 36  == 1.2 ​Features ==
... ... @@ -46,7 +46,8 @@
46 46  * Support wireless OTA update firmware
47 47  * Uplink on periodically
48 48  * Downlink to change configure
49 -* 8500mAh Battery for long term use
54 +* 88500mAh Li/SOCl2 Battery (S31/S31B-LB)
55 +* Solar panel + 3000mAh Li-on battery (S31/S31B-LS)
50 50  
51 51  == 1.3 Specification ==
52 52  
... ... @@ -53,7 +53,7 @@
53 53  
54 54  (% style="color:#037691" %)**Common DC Characteristics:**
55 55  
56 -* Supply Voltage: built in 8500mAh Li-SOCI2 battery , 2.5v ~~ 3.6v
62 +* Supply Voltage: Built-in Battery , 2.5v ~~ 3.6v
57 57  * Operating Temperature: -40 ~~ 85°C
58 58  
59 59  (% style="color:#037691" %)**Temperature Sensor:**
... ... @@ -120,7 +120,7 @@
120 120  == 1.6 BLE connection ==
121 121  
122 122  
123 -S31x-LB support BLE remote configure.
129 +S31x-LB/LS support BLE remote configure.
124 124  
125 125  
126 126  BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
... ... @@ -175,12 +175,12 @@
175 175  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675143909447-639.png]]
176 176  
177 177  
178 -= 2. Configure S31x-LB to connect to LoRaWAN network =
184 += 2. Configure S31x-LB/LS to connect to LoRaWAN network =
179 179  
180 180  == 2.1 How it works ==
181 181  
182 182  
183 -The S31x-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the S31x-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
189 +The S31x-LB/LS is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and press the button to activate the S31x-LB/LS. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
184 184  
185 185  
186 186  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
... ... @@ -191,9 +191,9 @@
191 191  The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
192 192  
193 193  
194 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from S31x-LB.
200 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from S31x-LB/LS.
195 195  
196 -Each S31x-LB is shipped with a sticker with the default device EUI as below:
202 +Each S31x-LB/LS is shipped with a sticker with the default device EUI as below:
197 197  
198 198  [[image:image-20230426084152-1.png||alt="图片-20230426084152-1.png" height="233" width="502"]]
199 199  
... ... @@ -222,10 +222,10 @@
222 222  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="图片-20220611161308-6.png"]]
223 223  
224 224  
225 -(% style="color:blue" %)**Step 2:**(%%) Activate on S31x-LB
231 +(% style="color:blue" %)**Step 2:**(%%) Activate on S31x-LB/LS
226 226  
227 227  
228 -Press the button for 5 seconds to activate the S31x-LB.
234 +Press the button for 5 seconds to activate the S31x-LB/LS.
229 229  
230 230  (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
231 231  
... ... @@ -237,7 +237,7 @@
237 237  === 2.3.1 Device Status, FPORT~=5 ===
238 238  
239 239  
240 -Users can use the downlink command(**0x26 01**) to ask S31x-LB to send device configure detail, include device configure status. S31x-LB will uplink a payload via FPort=5 to server.
246 +Users can use the downlink command(**0x26 01**) to ask S31x-LB/LS to send device configure detail, include device configure status. S31x-LB/LS will uplink a payload via FPort=5 to server.
241 241  
242 242  The Payload format is as below.
243 243  
... ... @@ -252,7 +252,7 @@
252 252  [[image:image-20230524144422-1.png||height="174" width="1080"]]
253 253  
254 254  
255 -(% style="color:#037691" %)**Sensor Model**(%%): For S31x-LB, this value is 0x0A
261 +(% style="color:#037691" %)**Sensor Model**(%%): For S31x-LB/LS, this value is 0x0A
256 256  
257 257  (% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
258 258  
... ... @@ -386,19 +386,19 @@
386 386  == 2.5 Datalog Feature ==
387 387  
388 388  
389 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB will store the reading for future retrieving purposes.
395 +Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, S31x-LB/LS will store the reading for future retrieving purposes.
390 390  
391 391  
392 392  === 2.5.1 Ways to get datalog via LoRaWAN ===
393 393  
394 394  
395 -Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
401 +Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayload28FPORT3D329"]], S31x-LB/LS will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB/LS will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
396 396  
397 397  * (((
398 -a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server.
404 +a) S31x-LB/LS will do an ACK check for data records sending to make sure every data arrive server.
399 399  )))
400 400  * (((
401 -b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages.
407 +b) S31x-LB/LS will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB/LS won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB/LS gets a ACK, S31x-LB/LS will consider there is a network connection and resend all NONE-ACK messages.
402 402  )))
403 403  
404 404  Below is the typical case for the auto-update datalog feature (Set PNACKMD=1)
... ... @@ -409,7 +409,7 @@
409 409  === 2.5.2 Unix TimeStamp ===
410 410  
411 411  
412 -S31x-LB uses Unix TimeStamp format based on
418 +S31x-LB/LS uses Unix TimeStamp format based on
413 413  
414 414  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-11.png?width=627&height=97&rev=1.1||alt="图片-20220523001219-11.png" height="97" width="627"]]
415 415  
... ... @@ -428,7 +428,7 @@
428 428  
429 429  User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command.
430 430  
431 -Once S31x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
437 +Once S31x-LB/LS Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB/LS. If S31x-LB/LS fails to get the time from the server, S31x-LB/LS will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
432 432  
433 433  (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
434 434  
... ... @@ -487,7 +487,7 @@
487 487  
488 488  **Example:**
489 489  
490 -If S31x-LB has below data inside Flash:
496 +If S31x-LB/LS has below data inside Flash:
491 491  
492 492  [[image:image-20230524114654-2.png]]
493 493  
... ... @@ -499,7 +499,7 @@
499 499   Stop time: 646D856C= time 23/5/24 03:33:00
500 500  
501 501  
502 -**S31x-LB will uplink this payload.**
508 +**S31x-LB/LS will uplink this payload.**
503 503  
504 504  [[image:image-20230524114826-3.png||height="448" width="1244"]]
505 505  
... ... @@ -537,7 +537,7 @@
537 537  == 2.6 Temperature Alarm Feature ==
538 538  
539 539  
540 -S31x-LB work flow with Alarm feature.
546 +S31x-LB/LS work flow with Alarm feature.
541 541  
542 542  
543 543  [[image:image-20230524110125-3.png||height="768" width="1115"]]
... ... @@ -547,7 +547,7 @@
547 547  == 2.7 Frequency Plans ==
548 548  
549 549  
550 -The S31x-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
556 +The S31x-LB/LS uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
551 551  
552 552  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
553 553  
... ... @@ -558,12 +558,12 @@
558 558  **Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/fis3g6nmhv0eokg/AAC6BcCZaX4BdqZkduUvZ3jIa?dl=0>>https://www.dropbox.com/sh/fis3g6nmhv0eokg/AAC6BcCZaX4BdqZkduUvZ3jIa?dl=0]]
559 559  
560 560  
561 -= 3. Configure S31x-LB =
567 += 3. Configure S31x-LB/LS =
562 562  
563 563  == 3.1 Configure Methods ==
564 564  
565 565  
566 -S31x-LB supports below configure method:
572 +S31x-LB/LS supports below configure method:
567 567  
568 568  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
569 569  * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
... ... @@ -582,10 +582,10 @@
582 582  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
583 583  
584 584  
585 -== 3.3 Commands special design for S31x-LB ==
591 +== 3.3 Commands special design for S31x-LB/LS ==
586 586  
587 587  
588 -These commands only valid for S31x-LB, as below:
594 +These commands only valid for S31x-LB/LS, as below:
589 589  
590 590  
591 591  === 3.3.1 Set Transmit Interval Time ===
... ... @@ -763,7 +763,7 @@
763 763  = 4. Battery & Power Consumption =
764 764  
765 765  
766 -S31x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
772 +S31x-LB use ER26500 + SPC1520 battery pack and S31x-LS use 3000mAh Recharable Battery with Solar Panel. See below link for detail information about the battery info and how to replace.
767 767  
768 768  [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
769 769  
... ... @@ -772,7 +772,7 @@
772 772  
773 773  
774 774  (% class="wikigeneratedid" %)
775 -User can change firmware S31x-LB to:
781 +User can change firmware S31x-LB/LS to:
776 776  
777 777  * Change Frequency band/ region.
778 778  * Update with new features.
... ... @@ -793,7 +793,7 @@
793 793  = 7. Order Info =
794 794  
795 795  
796 -Part Number: (% style="color:blue" %)**S31-LB-XX  / S31B-LB-XX**
802 +Part Number: (% style="color:blue" %)**S31-LB-XX / S31B-LB-XX**(%%)**  or  (% style="color:blue" %)S31-LS-XX / S31B-LS-XX(%%)**
797 797  
798 798  (% style="color:red" %)**XX**(%%): The default frequency band
799 799  
... ... @@ -818,7 +818,7 @@
818 818  
819 819  (% style="color:#037691" %)**Package Includes**:
820 820  
821 -* S31x-LB LoRaWAN Temperature & Humidity Sensor
827 +* S31x-LB or S31x-LS LoRaWAN Temperature & Humidity Sensor
822 822  
823 823  (% style="color:#037691" %)**Dimension and weight**:
824 824  
image-20240104161736-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +141.0 KB
Content
image-20240104162020-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +453.8 KB
Content
image-20240104162104-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +239.6 KB
Content
image-20240104162316-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +284.3 KB
Content