Last modified by Xiaoling on 2025/04/16 14:39
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.kai - Content
-
... ... @@ -134,7 +134,7 @@ 134 134 == 1.6 BLE connection == 135 135 136 136 137 - D2x-LB support BLE remote configure.137 +S31x-LB support BLE remote configure. 138 138 139 139 140 140 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -194,8 +194,6 @@ 194 194 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example. 195 195 196 196 197 - 198 - 199 199 The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 200 200 201 201 ... ... @@ -246,7 +246,7 @@ 246 246 === 2.3.1 Device Status, FPORT~=5 === 247 247 248 248 249 -Users can use the downlink command(**0x26 01**) to ask S31x-LB to send device configure detail, include device configure status. S31 x-LB will uplink a payload via FPort=5 to server.247 +Users can use the downlink command(**0x26 01**) to ask S31x-LB to send device configure detail, include device configure status. S31-LB will uplink a payload via FPort=5 to server. 250 250 251 251 The Payload format is as below. 252 252 ... ... @@ -258,7 +258,7 @@ 258 258 259 259 Example parse in TTNv3 260 260 261 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/image-20230415153147-2.png?width=1120&height=220&rev=1.1||alt="image-20230415153147-2.png"]]259 +[[image:image-20230421171614-1.png]] 262 262 263 263 264 264 (% style="color:#037691" %)**Sensor Model**(%%): For S31x-LB, this value is 0x0A ... ... @@ -335,7 +335,7 @@ 335 335 [[Humidity>>||anchor="HHumidity:"]] 336 336 ))) 337 337 338 -==== (% style="color:#4472c4" %)**Battery :**(%%) ====336 +==== (% style="color:#4472c4" %)**Battery**(%%) ==== 339 339 340 340 Sensor Battery Level. 341 341 ... ... @@ -345,7 +345,7 @@ 345 345 346 346 347 347 348 -==== (% style="color:#4472c4" %)**Temperature :**(%%) ====346 +==== (% style="color:#4472c4" %)**Temperature**(%%) ==== 349 349 350 350 **Example**: 351 351 ... ... @@ -356,13 +356,13 @@ 356 356 (FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 357 357 358 358 359 -==== (% style="color:#4472c4" %)**Humidity :**(%%) ====357 +==== (% style="color:#4472c4" %)**Humidity**(%%) ==== 360 360 361 361 362 362 Read:0x(0197)=412 Value: 412 / 10=41.2, So 41.2% 363 363 364 364 365 -==== (% style="color:#4472c4" %)**Alarm Flag& MOD :**(%%) ====363 +==== (% style="color:#4472c4" %)**Alarm Flag& MOD**(%%) ==== 366 366 367 367 368 368 **Example:** ... ... @@ -425,7 +425,7 @@ 425 425 426 426 User need to set (% style="color:blue" %)**SYNCMOD=1**(%%) to enable sync time via MAC command. 427 427 428 -Once S31 x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).426 +Once S31-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 429 429 430 430 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 431 431 ... ... @@ -472,7 +472,7 @@ 472 472 473 473 **Example:** 474 474 475 -If D2x-LB has below data inside Flash:473 +If S31-LB has below data inside Flash: 476 476 477 477 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523144455-1.png?width=735&height=335&rev=1.1||alt="image-20220523144455-1.png" height="335" width="735"]] 478 478 ... ... @@ -483,7 +483,7 @@ 483 483 Stop time: 60066DA7= time 21/1/19 05:27:03 484 484 485 485 486 -**S31 x-LB will uplink this payload.**484 +**S31-LB will uplink this payload.** 487 487 488 488 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-13.png?width=727&height=421&rev=1.1||alt="image-20220523001219-13.png" height="421" width="727"]] 489 489 ... ... @@ -541,7 +541,7 @@ 541 541 542 542 = 3. Configure S31x-LB = 543 543 544 -== 3.1 Configure Methods :==542 +== 3.1 Configure Methods == 545 545 546 546 547 547 S31x-LB supports below configure method: ... ... @@ -607,7 +607,7 @@ 607 607 Sensor will upload Device Status via FPORT=5. See payload section for detail. 608 608 609 609 610 -=== 3.3.3 Set Temperature Alarm Threshold :===608 +=== 3.3.3 Set Temperature Alarm Threshold === 611 611 612 612 * (% style="color:blue" %)**AT Command:** 613 613 ... ... @@ -623,12 +623,12 @@ 623 623 624 624 * (% style="color:blue" %)**Downlink Payload:** 625 625 626 -(% style="color:#037691" %)**0x(0C 01 00 1E)** (%%) ~/~/Set AT+SHTEMP=0,30 624 +(% style="color:#037691" %)**0x(0C 01 00 1E)** (%%) ~/~/ Set AT+SHTEMP=0,30 627 627 628 628 (% style="color:red" %)**(note: 3^^rd^^ byte= 0x00 for low limit(not set), 4^^th^^ byte = 0x1E for high limit: 30)** 629 629 630 630 631 -=== 3.3.4 Set Humidity Alarm Threshold :===629 +=== 3.3.4 Set Humidity Alarm Threshold === 632 632 633 633 * (% style="color:blue" %)**AT Command:** 634 634 ... ... @@ -640,16 +640,16 @@ 640 640 641 641 Example: 642 642 643 - AT+SHHUM=70,0 641 + AT+SHHUM=70,0 ~/~/ Alarm when humidity lower than 70%. 644 644 645 645 * (% style="color:blue" %)**Downlink Payload:** 646 646 647 -(% style="color:#037691" %)**0x(0C 02 46 00)**(%%) ~/~/Set AT+SHTHUM=70,0 645 +(% style="color:#037691" %)**0x(0C 02 46 00)**(%%) ~/~/ Set AT+SHTHUM=70,0 648 648 649 649 (% style="color:red" %)**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))** 650 650 651 651 652 -=== 3.3.5 Set Alarm Interval :===650 +=== 3.3.5 Set Alarm Interval === 653 653 654 654 The shortest time of two Alarm packet. (unit: min) 655 655 ... ... @@ -662,7 +662,7 @@ 662 662 (% style="color:#037691" %)**0x(0D 00 1E)**(%%) **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes 663 663 664 664 665 -=== 3.3.6 Get Alarm settings (什么FPORT?)===663 +=== 3.3.6 Get Alarm settings === 666 666 667 667 668 668 Send a LoRaWAN downlink to ask device send Alarm settings.
- image-20230421162630-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.5 KB - Content
- image-20230421171614-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.8 KB - Content