Last modified by Mengting Qiu on 2025/07/01 15:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -102,7 +102,7 @@ 102 102 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] 103 103 104 104 105 -(% border="1" cellspacing="4" style="background-color:# f2f2f2; width:510px" %)105 +(% border="1" cellspacing="4" style="background-color:#F2F2F2; width:510px" %) 106 106 |=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action** 107 107 |(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)((( 108 108 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once. ... ... @@ -133,9 +133,9 @@ 133 133 == 1.7 Hardware Variant == 134 134 135 135 136 -(% border="1" cellspacing="5" style="background-color:# f2f2f2; width:510px" %)136 +(% border="1" cellspacing="5" style="background-color:#F2F2F2; width:510px" %) 137 137 |=(% style="width: 102px;background-color:#D9E2F3;color:#0070C0" %)Model|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)Photo|=(% style="width: 297px;background-color:#D9E2F3;color:#0070C0" %)Probe Info 138 -|(% style="width:102px" %)S31-LB|(% style="width:190px" %) |(% style="width:297px" %)((( 138 +|(% style="width:102px" %)**S31-LB**|(% style="width:190px" %) |(% style="width:297px" %)((( 139 139 1 x SHT31 Probe 140 140 141 141 Cable Length : 2 meters ... ... @@ -142,7 +142,7 @@ 142 142 143 143 144 144 ))) 145 -|(% style="width:102px" %)S31B-LB|(% style="width:190px" %) |(% style="width:297px" %)((( 145 +|(% style="width:102px" %)**S31B-LB**|(% style="width:190px" %) |(% style="width:297px" %)((( 146 146 1 x SHT31 Probe 147 147 148 148 Installed in device. ... ... @@ -178,6 +178,7 @@ 178 178 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example. 179 179 180 180 181 +[[image:1675144005218-297.png]] 181 181 182 182 183 183 The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. ... ... @@ -187,7 +187,7 @@ 187 187 188 188 Each S31x-LB is shipped with a sticker with the default device EUI as below: 189 189 190 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220607170145-1.jpeg?rev=1.1||alt="image-20220607170145-1.jpeg"]]191 +[[image:image-20230131134744-2.jpeg]] 191 191 192 192 193 193 ... ... @@ -196,23 +196,23 @@ 196 196 197 197 (% style="color:blue" %)**Register the device** 198 198 199 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/1654935135620-998.png?rev=1.1||alt="1654935135620-998.png"]]200 +[[image:1675144099263-405.png]] 200 200 201 201 202 202 (% style="color:blue" %)**Add APP EUI and DEV EUI** 203 203 204 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-4.png?width=753&height=551&rev=1.1||alt="image-20220611161308-4.png"]]205 +[[image:1675144117571-832.png]] 205 205 206 206 207 207 (% style="color:blue" %)**Add APP EUI in the application** 208 208 209 209 210 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-5.png?width=742&height=601&rev=1.1||alt="image-20220611161308-5.png"]]211 +[[image:1675144143021-195.png]] 211 211 212 212 213 213 (% style="color:blue" %)**Add APP KEY** 214 214 215 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50v2-S31-S31B%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/WebHome/image-20220611161308-6.png?width=744&height=485&rev=1.1||alt="image-20220611161308-6.png"]]216 +[[image:1675144157838-392.png]] 216 216 217 217 218 218 (% style="color:blue" %)**Step 2:**(%%) Activate on S31x-LB ... ... @@ -235,14 +235,14 @@ 235 235 The Payload format is as below. 236 236 237 237 238 -(% border="1" cellspacing="4" style="background-color:#f 2f2f2; width:510px" %)239 -|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0"%)**Device Status (FPORT=5)**239 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 240 +|(% colspan="6" %)**Device Status (FPORT=5)** 240 240 |(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 241 241 |(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 242 242 243 243 Example parse in TTNv3 244 244 245 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/image-20230415153147-2.png?width=1120&height=220&rev=1.1||alt="image-20230415153147-2.png"]]246 +[[image:image-20230415153147-2.png||height="220" width="1120"]] 246 246 247 247 248 248 (% style="color:#037691" %)**Sensor Model**(%%): For S31x-LB, this value is 0x0A ... ... @@ -303,20 +303,19 @@ 303 303 304 304 Sensor Data is uplink via FPORT=2 305 305 306 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 307 -|=(% style="width: 99px;background-color:#D9E2F3" %)((( 307 +|=((( 308 308 **Size(bytes)** 309 -)))|= (% style="width: 69px;background-color:#D9E2F3" %)2|=(% style="width: 130px;background-color:#D9E2F3" %)4|=(% style="width: 91px;background-color:#D9E2F3" %)1|=(% style="width: 103px;background-color:#D9E2F3" %)**2**|=(% style="width: 80px;background-color:#D9E2F3" %)2310 -| (% style="width:99px" %)**Value**|(% style="width:69px" %)(((311 -[[Battery>> ||anchor="HBattery:"]]312 -)))|( % style="width:130px" %)(((313 -[[Unix TimeStamp>> ||anchor="H2.5.2UnixTimeStamp"]]314 -)))|( % style="width:91px" %)(((315 -[[Alarm Flag>> ||anchor="HAlarmFlag26MOD:"]]316 -)))|( % style="width:103px" %)(((317 -[[Temperature>> ||anchor="HTemperature:"]]318 -)))|( % style="width:80px" %)(((319 -[[Humidity>> ||anchor="HHumidity:"]]309 +)))|=2|=4|=1|=**2**|=2 310 +|**Value**|((( 311 +[[Battery>>path:#HBattery:]] 312 +)))|((( 313 +[[Unix TimeStamp>>path:#H2.4.1UnixTimeStamp]] 314 +)))|((( 315 +[[Alarm Flag>>path:#HAlarmFlag26MOD:]] 316 +)))|((( 317 +[[Temperature>>path:#HTemperature:]] 318 +)))|((( 319 +[[Humidity>>path:#HHumidity:]] 320 320 ))) 321 321 322 322 ==== (% style="color:#4472c4" %)**Battery:**(%%) ==== ... ... @@ -362,7 +362,6 @@ 362 362 363 363 == 2.4 Payload Decoder file == 364 364 365 - 366 366 In TTN, use can add a custom payload so it shows friendly reading 367 367 368 368 In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: ... ... @@ -379,7 +379,7 @@ 379 379 === 2.5.1 Ways to get datalog via LoRaWAN === 380 380 381 381 382 -Set [[PNACKMD=1>> ||anchor="H2.5.4DatalogUplinkpayloadA028FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.381 +Set [[PNACKMD=1>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.13AutoSendNone-ACKmessages]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 383 383 384 384 * a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server. 385 385 * b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages. ... ... @@ -407,11 +407,11 @@ 407 407 === 2.5.3 Set Device Time === 408 408 409 409 410 -User need to set (% style="color:blue" %)**SYNCMOD=1**(%%)to enable sync time via MAC command.409 +User need to set **SYNCMOD=1** to enable sync time via MAC command. 411 411 412 412 Once S31x-LB Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to S31x-LB. If S31x-LB fails to get the time from the server, S31x-LB will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days). 413 413 414 - (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**413 +**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 415 415 416 416 417 417 === 2.5.4 Datalog Uplink payload (FPORT~=3) === ... ... @@ -421,19 +421,19 @@ 421 421 422 422 **Retrieval data payload:** 423 423 424 -(% border="1" cellspacing="5" style="background-color:#f2f2f2;width:510px" %)425 -|=(% style="width: 103px; background-color:#D9E2F3" %)(((423 +(% style="width:858px" %) 424 +|=(% style="width: 103px;" %)((( 426 426 **Size(bytes)** 427 -)))|=(% style="width: 54px;background-color: rgb(217, 226, 243);" %)**2**|=(% style="width:51px;background-color: rgb(217, 226, 243);" %)**2**|=(% style="width:89px; background-color: rgb(217, 226, 243);" %)**2**|=(% style="width: 103px;background-color: rgb(217, 226, 243);" %)**1**|=(% style="width:54px;background-color: rgb(217, 226, 243);" %)**4**428 -|(% style="width:103px" %)**Value**|(% style="width: 54px" %)(((426 +)))|=(% style="width: 129px;" %)**2**|=(% style="width: 114px;" %)**2**|=(% style="width: 217px;" %)**2**|=(% style="width: 153px;" %)**1**|=(% style="width: 139px;" %)**4** 427 +|(% style="width:103px" %)**Value**|(% style="width:129px" %)((( 429 429 [[Temp_Black>>||anchor="HTemperatureBlack:"]] 430 -)))|(% style="width: 51px" %)[[Temp_White>>||anchor="HTemperatureWhite:"]]|(% style="width:89px" %)[[Temp_ Red or Temp _White>>||anchor="HTemperatureREDorTemperatureWhite:"]]|(% style="width:103px" %)Poll message flag & Ext|(% style="width:54px" %)[[Unix Time Stamp>>||anchor="H2.5.2UnixTimeStamp"]]429 +)))|(% style="width:114px" %)[[Temp_White>>||anchor="HTemperatureWhite:"]]|(% style="width:217px" %)[[Temp_ Red or Temp _White>>||anchor="HTemperatureREDorTemperatureWhite:"]]|(% style="width:153px" %)Poll message flag & Ext|(% style="width:139px" %)[[Unix Time Stamp>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.6.2UnixTimeStamp]] 431 431 432 432 **Poll message flag & Ext:** 433 433 434 434 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20221006192726-1.png?width=754&height=112&rev=1.1||alt="image-20221006192726-1.png" height="112" width="754"]] 435 435 436 -**No ACK Message**: 1: This message means this payload is fromn Uplink Message which doesn't get ACK from the server before ( for **PNACKMD=1**feature)435 +**No ACK Message**: 1: This message means this payload is fromn Uplink Message which doesn't get ACK from the server before ( for [[PNACKMD=1>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.13AutoSendNone-ACKmessages]] feature) 437 437 438 438 **Poll Message Flag**: 1: This message is a poll message reply. 439 439 ... ... @@ -465,7 +465,6 @@ 465 465 466 466 Stop time: 60066DA7= time 21/1/19 05:27:03 467 467 468 - 469 469 **S31x-LB will uplink this payload.** 470 470 471 471 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20220523001219-13.png?width=727&height=421&rev=1.1||alt="image-20220523001219-13.png" height="421" width="727"]]