Last modified by Mengting Qiu on 2025/07/01 15:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -235,14 +235,14 @@ 235 235 The Payload format is as below. 236 236 237 237 238 -(% border="1" cellspacing="4" style="background-color:#f 7faff;color:black;width:510px" %)239 -|(% colspan="6" %)**Device Status (FPORT=5)** 238 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 239 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 240 240 |(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 241 241 |(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 242 242 243 243 Example parse in TTNv3 244 244 245 -[[image:image-20230415153147-2.png ||height="220" width="1120"]]245 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/image-20230415153147-2.png?width=1120&height=220&rev=1.1||alt="image-20230415153147-2.png"]] 246 246 247 247 248 248 (% style="color:#037691" %)**Sensor Model**(%%): For S31x-LB, this value is 0x0A ... ... @@ -303,19 +303,20 @@ 303 303 304 304 Sensor Data is uplink via FPORT=2 305 305 306 -|=((( 306 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 307 +|=(% style="width: 99px;background-color:#D9E2F3" %)((( 307 307 **Size(bytes)** 308 -)))|=2|=4|=1|=**2**|=2 309 -|**Value**|((( 310 -[[Battery>> path:#HBattery:]]311 -)))|((( 312 -[[Unix TimeStamp>> path:#H2.4.1UnixTimeStamp]]313 -)))|((( 314 -[[Alarm Flag>> path:#HAlarmFlag26MOD:]]315 -)))|((( 316 -[[Temperature>> path:#HTemperature:]]317 -)))|((( 318 -[[Humidity>> path:#HHumidity:]]309 +)))|=(% style="width: 69px;background-color:#D9E2F3" %)2|=(% style="width: 130px;background-color:#D9E2F3" %)4|=(% style="width: 91px;background-color:#D9E2F3" %)1|=(% style="width: 103px;background-color:#D9E2F3" %)**2**|=(% style="width: 80px;background-color:#D9E2F3" %)2 310 +|(% style="width:99px" %)**Value**|(% style="width:69px" %)((( 311 +[[Battery>>||anchor="HBattery:"]] 312 +)))|(% style="width:130px" %)((( 313 +[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 314 +)))|(% style="width:91px" %)((( 315 +[[Alarm Flag>>||anchor="HAlarmFlag26MOD:"]] 316 +)))|(% style="width:103px" %)((( 317 +[[Temperature>>||anchor="HTemperature:"]] 318 +)))|(% style="width:80px" %)((( 319 +[[Humidity>>||anchor="HHumidity:"]] 319 319 ))) 320 320 321 321 ==== (% style="color:#4472c4" %)**Battery:**(%%) ==== ... ... @@ -361,6 +361,7 @@ 361 361 362 362 == 2.4 Payload Decoder file == 363 363 365 + 364 364 In TTN, use can add a custom payload so it shows friendly reading 365 365 366 366 In the page (% style="color:#037691" %)**Applications ~-~-> Payload Formats ~-~-> Custom ~-~-> decoder**(%%) to add the decoder from: ... ... @@ -377,7 +377,7 @@ 377 377 === 2.5.1 Ways to get datalog via LoRaWAN === 378 378 379 379 380 -Set [[PNACKMD=1>> url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.13AutoSendNone-ACKmessages]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.382 +Set [[PNACKMD=1>>||anchor="H2.5.4DatalogUplinkpayloadA028FPORT3D329"]], S31x-LB will wait for ACK for every uplink, when there is no LoRaWAN network,S31x-LB will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 381 381 382 382 * a) S31x-LB will do an ACK check for data records sending to make sure every data arrive server. 383 383 * b) S31x-LB will send data in **CONFIRMED Mode** when PNACKMD=1, but S31x-LB won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if S31x-LB gets a ACK, S31x-LB will consider there is a network connection and resend all NONE-ACK messages.