From version < 61.15 >
edited by Xiaoling
on 2022/06/14 11:47
To version < 61.46 >
edited by Xiaoling
on 2022/06/25 16:06
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,6 +12,11 @@
12 12  
13 13  
14 14  
15 +
16 +
17 +
18 +
19 +
15 15  **Table of Contents:**
16 16  
17 17  {{toc/}}
... ... @@ -80,13 +80,11 @@
80 80  ** Idle: 32mA@12v
81 81  ** 20dB Transmit: 65mA@12v
82 82  
83 -
84 84  **Interface for Model:**
85 85  
86 86  * RS485
87 87  * Power Input 7~~ 24V DC. 
88 88  
89 -
90 90  **LoRa Spec:**
91 91  
92 92  * Frequency Range:
... ... @@ -109,8 +109,6 @@
109 109  * Packet engine up to 256 bytes with CRC
110 110  
111 111  
112 -
113 -
114 114  == 1.3 Features ==
115 115  
116 116  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -123,8 +123,6 @@
123 123  * Support Interrupt uplink (Since hardware version v1.2)
124 124  
125 125  
126 -
127 -
128 128  == 1.4 Applications ==
129 129  
130 130  * Smart Buildings & Home Automation
... ... @@ -135,8 +135,6 @@
135 135  * Smart Factory
136 136  
137 137  
138 -
139 -
140 140  == 1.5 Firmware Change log ==
141 141  
142 142  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -339,6 +339,8 @@
339 339  )))
340 340  
341 341  
339 +
340 +
342 342  === 3.3.2 Configure sensors ===
343 343  
344 344  (((
... ... @@ -364,6 +364,9 @@
364 364  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
365 365  
366 366  
366 +
367 +
368 +
367 367  === 3.3.3 Configure read commands for each sampling ===
368 368  
369 369  (((
... ... @@ -585,7 +585,7 @@
585 585  
586 586  
587 587  
588 -==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====
590 +==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ====
589 589  
590 590  (((
591 591  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -592,15 +592,15 @@
592 592  )))
593 593  
594 594  * (((
595 -**(% style="color:#037691" %)AT Command**
597 +(% style="color:#037691" %)**AT Command**
596 596  
597 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
598 -
599 -
599 +(((
600 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
600 600  )))
602 +)))
601 601  
602 602  (((
603 -m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
605 +
604 604  )))
605 605  
606 606  * (((
... ... @@ -641,7 +641,9 @@
641 641  )))
642 642  
643 643  (((
644 -**Example 1** ~-~-> Configure without ask for uplink (YY=0)
646 +
647 +
648 +**Example 1**  ~-~-> Configure without ask for uplink (YY=0)
645 645  )))
646 646  
647 647  (((
... ... @@ -657,6 +657,8 @@
657 657  )))
658 658  
659 659  (((
664 +
665 +
660 660  So if user want to use downlink command to control to RS485 Alarm, he can use:
661 661  )))
662 662  
... ... @@ -677,7 +677,7 @@
677 677  )))
678 678  
679 679  (((
680 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
686 +**Example 2**  ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
681 681  )))
682 682  
683 683  (((
... ... @@ -689,11 +689,11 @@
689 689  )))
690 690  
691 691  (((
692 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
698 +(((
699 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
693 693  )))
694 694  
695 -(((
696 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
702 +
697 697  )))
698 698  
699 699  (((
... ... @@ -703,7 +703,7 @@
703 703  
704 704  
705 705  
706 -==== **(% style="color:blue" %)Set Payload version** ====
712 +==== (% style="color:blue" %)**Set Payload version**(%%) ====
707 707  
708 708  (((
709 709  This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
... ... @@ -710,32 +710,28 @@
710 710  )))
711 711  
712 712  * (((
713 -**(% style="color:#037691" %)AT Command:**
714 -)))
719 +(% style="color:#037691" %)**AT Command:**
715 715  
716 -(% class="box infomessage" %)
717 -(((
718 -(((
719 -**AT+PAYVER: Set PAYVER field = 1**
720 -)))
721 -)))
721 +**AT+PAYVER:    **Set PAYVER field = 1
722 722  
723 +
724 +)))
723 723  * (((
724 -**(% style="color:#037691" %)Downlink Payload:**
726 +(% style="color:#037691" %)**Downlink Payload:**
725 725  )))
726 726  
727 727  (((
728 -**0xAE 01**  ~-~-> Set PAYVER field =  0x01
730 +**0xAE 01**  ~-~->  Set PAYVER field =  0x01
729 729  )))
730 730  
731 731  (((
732 -**0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
734 +**0xAE 0F**   ~-~->  Set PAYVER field =  0x0F
733 733  )))
734 734  
735 735  
736 736  
737 737  
738 -==== **(% style="color:blue" %)Set RS485 Sampling Commands** ====
740 +==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ====
739 739  
740 740  (((
741 741  AT+COMMANDx or AT+DATACUTx
... ... @@ -750,18 +750,16 @@
750 750  )))
751 751  
752 752  * (((
753 -**(% style="color:#037691" %)AT Command:**
755 +(% style="color:#037691" %)**AT Command:**
754 754  )))
755 755  
758 +**AT+COMMANDx:    **Configure RS485 read command to sensor.
756 756  
757 -**AT+COMMANDx: Configure RS485 read command to sensor.**
760 +**AT+DATACUTx:        **Configure how to handle return from RS485 devices.
758 758  
759 759  
760 -**AT+DATACUTx: Configure how to handle return from RS485 devices.**
761 -
762 -
763 763  * (((
764 -**(% style="color:#037691" %)Downlink Payload:**
764 +(% style="color:#037691" %)**Downlink Payload:**
765 765  )))
766 766  
767 767  (((
... ... @@ -797,6 +797,8 @@
797 797  )))
798 798  
799 799  (((
800 +
801 +
800 800  **Example:**
801 801  )))
802 802  
... ... @@ -815,10 +815,10 @@
815 815  
816 816  
817 817  
818 -==== **(% style="color:blue" %)Fast command to handle MODBUS device** ====
820 +==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
819 819  
820 820  (((
821 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
823 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
822 822  )))
823 823  
824 824  (((
... ... @@ -838,23 +838,25 @@
838 838  )))
839 839  
840 840  * (((
841 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
843 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2  are not configure (0,0,0). So RS485-LN.
842 842  )))
843 843  * (((
844 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
846 +AT+COMMAND1= 01 03 00 10 00 08,1  ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
845 845  )))
846 846  * (((
847 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
849 +AT+COMMAND2= 01 02 00 40 00 10,1  ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
850 +
851 +
848 848  )))
849 849  
850 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
854 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %)​
851 851  
852 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
856 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %)​
853 853  
854 854  
855 855  
856 856  
857 -==== **(% style="color:blue" %)RS485 command timeout** ====
861 +==== (% style="color:blue" %)**RS485 command timeout**(%%) ====
858 858  
859 859  (((
860 860  Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
... ... @@ -865,17 +865,14 @@
865 865  )))
866 866  
867 867  * (((
868 -**(% style="color:#037691" %) AT Command:**
869 -)))
872 +(% style="color:#037691" %)** AT Command:**
870 870  
871 -(% class="box infomessage" %)
872 -(((
873 -(((
874 874  **AT+CMDDLaa=hex(bb cc)*1000**
875 875  )))
876 -)))
877 877  
878 878  (((
878 +
879 +
879 879  **Example:**
880 880  )))
881 881  
... ... @@ -888,7 +888,7 @@
888 888  )))
889 889  
890 890  * (((
891 -**(% style="color:#037691" %) Downlink Payload:**
892 +(% style="color:#037691" %)** Downlink Payload:**
892 892  )))
893 893  
894 894  (((
... ... @@ -900,17 +900,17 @@
900 900  )))
901 901  
902 902  (((
903 - **Example:**
904 +**Example:**
904 904  )))
905 905  
906 906  (((
907 - 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
908 +**0xAA 01 00 01**  ~-~-> Same as  **AT+CMDDL1=1000 ms**
908 908  )))
909 909  
910 910  
911 911  
912 912  
913 -==== **(% style="color:blue" %)Uplink payload mode** ====
914 +==== (% style="color:blue" %)**Uplink payload mode**(%%) ====
914 914  
915 915  (((
916 916  Define to use one uplink or multiple uplinks for the sampling.
... ... @@ -918,13 +918,14 @@
918 918  
919 919  (((
920 920  The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
922 +
923 +
921 921  )))
922 922  
923 923  * (((
924 -**(% style="color:#037691" %) AT Command:**
927 +(% style="color:#037691" %)** AT Command:**
925 925  )))
926 926  
927 -
928 928  **AT+DATAUP=0**
929 929  
930 930  **AT+DATAUP=1**
... ... @@ -931,7 +931,7 @@
931 931  
932 932  
933 933  * (((
934 -**(% style="color:#037691" %) Downlink Payload:**
936 +(% style="color:#037691" %)** Downlink Payload:**
935 935  )))
936 936  
937 937  (((
... ... @@ -945,7 +945,7 @@
945 945  
946 946  
947 947  
948 -==== **(% style="color:blue" %)Manually trigger an Uplink** ====
950 +==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ====
949 949  
950 950  (((
951 951  Ask device to send an uplink immediately.
... ... @@ -952,7 +952,7 @@
952 952  )))
953 953  
954 954  * (((
955 -**(% style="color:#037691" %) AT Command:**
957 +(% style="color:#037691" %)** AT Command:**
956 956  )))
957 957  
958 958  (((
... ... @@ -964,7 +964,7 @@
964 964  )))
965 965  
966 966  * (((
967 -**(% style="color:#037691" %) Downlink Payload:**
969 +(% style="color:#037691" %)** Downlink Payload:**
968 968  )))
969 969  
970 970  (((
... ... @@ -974,14 +974,16 @@
974 974  
975 975  
976 976  
977 -==== **(% style="color:blue" %)Clear RS485 Command** ====
979 +==== (% style="color:blue" %)**Clear RS485 Command**(%%) ====
978 978  
979 979  (((
980 980  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
983 +
984 +
981 981  )))
982 982  
983 983  * (((
984 -**(% style="color:#037691" %) AT Command:**
988 +(% style="color:#037691" %)** AT Command:**
985 985  )))
986 986  
987 987  (((
... ... @@ -1008,7 +1008,7 @@
1008 1008  
1009 1009  
1010 1010  * (((
1011 -**(% style="color:#037691" %) Downlink Payload:**
1015 +(% style="color:#037691" %)** Downlink Payload:**
1012 1012  )))
1013 1013  
1014 1014  (((
... ... @@ -1018,7 +1018,7 @@
1018 1018  
1019 1019  
1020 1020  
1021 -==== **(% style="color:blue" %)Set Serial Communication Parameters** ====
1025 +==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ====
1022 1022  
1023 1023  (((
1024 1024  Set the Rs485 serial communication parameters:
... ... @@ -1025,39 +1025,39 @@
1025 1025  )))
1026 1026  
1027 1027  * (((
1028 -**(% style="color:#037691" %) AT Command:**
1032 +(% style="color:#037691" %)** AT Command:**
1029 1029  )))
1030 1030  
1031 1031  (((
1032 -Set Baud Rate:
1036 +
1037 +
1038 +* Set Baud Rate
1033 1033  )))
1034 1034  
1035 -
1036 1036  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1037 1037  
1038 1038  
1039 1039  (((
1040 -Set UART Parity
1045 +* Set UART Parity
1041 1041  )))
1042 1042  
1043 -
1044 1044  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1045 1045  
1046 1046  
1047 1047  (((
1048 -Set STOPBIT
1052 +* Set STOPBIT
1049 1049  )))
1050 1050  
1051 -
1052 1052  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1053 1053  
1054 1054  
1058 +
1055 1055  * (((
1056 -**(% style="color:#037691" %) Downlink Payload:**
1060 +(% style="color:#037691" %)** Downlink Payload:**
1057 1057  )))
1058 1058  
1059 1059  (((
1060 -**A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1064 +**A7 01 aa bb**:  Same  AT+BAUDR=hex(aa bb)*100
1061 1061  )))
1062 1062  
1063 1063  (((
... ... @@ -1072,11 +1072,11 @@
1072 1072  )))
1073 1073  
1074 1074  (((
1075 -A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1079 +A7 02 aa:  Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1076 1076  )))
1077 1077  
1078 1078  (((
1079 -A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1083 +A7 03 aa:  Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1080 1080  )))
1081 1081  
1082 1082  
... ... @@ -1130,7 +1130,7 @@
1130 1130  )))
1131 1131  
1132 1132  (((
1133 -**Downlink Command:**
1137 +(% style="color:#037691" %)** Downlink Command:**
1134 1134  )))
1135 1135  
1136 1136  (((
... ... @@ -1189,6 +1189,9 @@
1189 1189  |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1190 1190  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1191 1191  
1196 +
1197 +
1198 +
1192 1192  == 3.8 LEDs ==
1193 1193  
1194 1194  
... ... @@ -1197,6 +1197,9 @@
1197 1197  |**PWR**|Always on if there is power
1198 1198  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1199 1199  
1207 +
1208 +
1209 +
1200 1200  = 4. Case Study =
1201 1201  
1202 1202  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1228,38 +1228,24 @@
1228 1228  
1229 1229  == 5.2 Common AT Command Sequence ==
1230 1230  
1241 +
1231 1231  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1232 1232  
1233 1233  If device has not joined network yet:
1234 1234  
1235 -(% class="box infomessage" %)
1236 -(((
1237 -**AT+FDR**
1238 -)))
1246 +* (% style="color:#037691" %)**AT+FDR**
1247 +* (% style="color:#037691" %)**AT+NJM=0**
1248 +* (% style="color:#037691" %)**ATZ**
1239 1239  
1240 -(% class="box infomessage" %)
1241 1241  (((
1242 -**AT+NJM=0**
1243 -)))
1251 +
1244 1244  
1245 -(% class="box infomessage" %)
1246 -(((
1247 -**ATZ**
1248 -)))
1249 -
1250 -
1251 -(((
1252 1252  If device already joined network:
1253 -)))
1254 1254  
1255 -(% class="box infomessage" %)
1256 -(((
1257 -**AT+NJM=0**
1258 -)))
1255 +* (% style="color:#037691" %)**AT+NJM=0**
1256 +* (% style="color:#037691" %)**ATZ**
1259 1259  
1260 -(% class="box infomessage" %)
1261 -(((
1262 -**ATZ**
1258 +
1263 1263  )))
1264 1264  
1265 1265  
... ... @@ -1266,25 +1266,25 @@
1266 1266  === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1267 1267  
1268 1268  
1269 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1265 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1270 1270  
1271 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode
1267 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode
1272 1272  
1273 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
1269 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off
1274 1274  
1275 -(% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%)Set Data Rate
1271 +(% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%) Set Data Rate
1276 1276  
1277 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1273 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1278 1278  
1279 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz
1275 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%)  Set transmit frequency to 868.4Mhz
1280 1280  
1281 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1277 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1282 1282  
1283 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1279 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1284 1284  
1285 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1281 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1286 1286  
1287 -(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1283 +(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1288 1288  
1289 1289  
1290 1290  (% style="color:red" %)**Note:**
... ... @@ -1404,6 +1404,7 @@
1404 1404  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1405 1405  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1406 1406  
1403 +
1407 1407  = 9.Packing Info =
1408 1408  
1409 1409  
... ... @@ -1420,6 +1420,7 @@
1420 1420  * Package Size / pcs : 14.5 x 8 x 5 cm
1421 1421  * Weight / pcs : 170g
1422 1422  
1420 +
1423 1423  = 10. FCC Caution for RS485LN-US915 =
1424 1424  
1425 1425  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0