From version < 38.1 >
edited by Xiaoling
on 2022/06/02 16:09
To version < 33.1 >
edited by Xiaoling
on 2022/06/02 15:36
>
Change comment: Uploaded new attachment "image-20220602153621-1.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -76,6 +76,8 @@
76 76  * Automatic RF Sense and CAD with ultra-fast AFC.
77 77  * Packet engine up to 256 bytes with CRC.
78 78  
79 +
80 +
79 79  == 1.3 Features ==
80 80  
81 81  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -87,6 +87,8 @@
87 87  * Support Modbus protocol
88 88  * Support Interrupt uplink (Since hardware version v1.2)
89 89  
92 +
93 +
90 90  == 1.4 Applications ==
91 91  
92 92  * Smart Buildings & Home Automation
... ... @@ -96,6 +96,8 @@
96 96  * Smart Cities
97 97  * Smart Factory
98 98  
103 +
104 +
99 99  == 1.5 Firmware Change log ==
100 100  
101 101  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -283,6 +283,8 @@
283 283  )))
284 284  )))
285 285  
292 +
293 +
286 286  === 3.3.2 Configure sensors ===
287 287  
288 288  (((
... ... @@ -301,37 +301,82 @@
301 301  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
302 302  )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
303 303  
312 +
313 +
304 304  === 3.3.3 Configure read commands for each sampling ===
305 305  
306 306  (((
307 -During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload.
317 +RS485-BL is a battery powered device; it will sleep most of time. And wake up on each period and read RS485 / TTL sensor data and uplink.
318 +)))
308 308  
320 +(((
321 +During each sampling, we need to confirm what commands we need to send to the sensors to read data. After the RS485/TTL sensors send back the value, it normally includes some bytes and we only need a few from them for a shorten payload.
322 +)))
323 +
324 +(((
309 309  To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload.
326 +)))
310 310  
328 +(((
311 311  This section describes how to achieve above goals.
330 +)))
312 312  
313 -During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
332 +(((
333 +During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
334 +)))
314 314  
336 +(((
337 +**Command from RS485-BL to Sensor:**
338 +)))
315 315  
316 -**Each RS485 commands include two parts:**
340 +(((
341 +RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar.
342 +)))
317 317  
318 -~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar.
344 +(((
345 +**Handle return from sensors to RS485-BL**:
346 +)))
319 319  
320 -2. How to get wanted value the from RS485 sensors returns from by 1). There are total 15 AT Commands to handle the return, commands are **AT+DATACUT1**,**AT+DATACUT2**,…, **AT+DATACUTF** corresponding to the commands from 1). All commands are of same grammar.
348 +(((
349 +After RS485-BL send out a string to sensor, RS485-BL will wait for the return from RS485 or TTL sensor. And user can specify how to handle the return, by **AT+DATACUT or AT+SEARCH commands**
350 +)))
321 321  
322 -3. Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example **AT+CMDDL1=1000** to send the open time to 1000ms
352 +* (((
353 +**AT+DATACUT**
354 +)))
323 323  
356 +(((
357 +When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command.
358 +)))
324 324  
360 +* (((
361 +**AT+SEARCH**
362 +)))
363 +
364 +(((
365 +When the return value from sensor is dynamic length and we are not sure which bytes the valid data is, instead, we know what value the valid value following. We can use AT+SEARCH to search the valid value in the return string.
366 +)))
367 +
368 +(((
369 +**Define wait timeout:**
370 +)))
371 +
372 +(((
373 +Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example, AT+CMDDL1=1000 to send the open time to 1000ms
374 +)))
375 +
376 +(((
325 325  After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
378 +)))
326 326  
380 +**Examples:**
327 327  
328 328  Below are examples for the how above AT Commands works.
329 329  
384 +**AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
330 330  
331 -**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
332 -
333 -(% border="1" style="background-color:#4bacc6; color:white; width:499px" %)
334 -|(% style="width:496px" %)(((
386 +(% border="1" class="table-bordered" %)
387 +|(((
335 335  **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
336 336  
337 337  **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
... ... @@ -339,15 +339,49 @@
339 339  **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command**
340 340  )))
341 341  
395 +(((
342 342  For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually.
397 +)))
343 343  
344 -In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
399 +(((
400 +In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
401 +)))
345 345  
403 +(((
404 +**AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
405 +)))
346 346  
407 +(% border="1" class="table-bordered" %)
408 +|(((
409 +**AT+SEARCHx=aa,xx xx xx xx xx**
410 +
411 +* **aa: 1: prefix match mode; 2: prefix and suffix match mode**
412 +* **xx xx xx xx xx: match string. Max 5 bytes for prefix and 5 bytes for suffix**
413 +
414 +
415 +)))
416 +
417 +**Examples:**
418 +
419 +~1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
420 +
421 +If we set AT+SEARCH1=1,1E 56 34.      (max 5 bytes for prefix)
422 +
423 +The valid data will be all bytes after 1E 56 34 , so it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30 31 00 49**
424 +
425 +[[image:1653269403619-508.png]]
426 +
427 +2. For a return string from AT+COMMAND1:  16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
428 +
429 +If we set AT+SEARCH1=2, 1E 56 34+31 00 49
430 +
431 +Device will search the bytes between 1E 56 34 and 31 00 49. So it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30**
432 +
433 +[[image:1653269438444-278.png]]
434 +
347 347  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
348 348  
349 -(% border="1" style="background-color:#4bacc6; color:white; width:725px" %)
350 -|(% style="width:722px" %)(((
437 +|(((
351 351  **AT+DATACUTx=a,b,c**
352 352  
353 353  * **a: length for the return of AT+COMMAND**
... ... @@ -355,37 +355,48 @@
355 355  * **c: define the position for valid value.  **
356 356  )))
357 357  
358 -**Examples:**
445 +Examples:
359 359  
360 360  * Grab bytes:
361 361  
362 -[[image:image-20220602153621-1.png]]
449 +[[image:1653269551753-223.png||height="311" width="717"]]
363 363  
364 -
365 365  * Grab a section.
366 366  
367 -[[image:image-20220602153621-2.png]]
453 +[[image:1653269568276-930.png||height="325" width="718"]]
368 368  
369 -
370 370  * Grab different sections.
371 371  
372 -[[image:image-20220602153621-3.png]]
457 +[[image:1653269593172-426.png||height="303" width="725"]]
373 373  
374 -
375 -)))
459 +(% style="color:red" %)**Note:**
376 376  
461 +AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0.
462 +
463 +Example:
464 +
465 +(% style="color:red" %)AT+COMMAND1=11 01 1E D0,0
466 +
467 +(% style="color:red" %)AT+SEARCH1=1,1E 56 34
468 +
469 +(% style="color:red" %)AT+DATACUT1=0,2,1~~5
470 +
471 +(% style="color:red" %)Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
472 +
473 +(% style="color:red" %)String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49
474 +
475 +(% style="color:red" %)Valid payload after DataCUT command: 2e 30 58 5f 36
476 +
477 +[[image:1653269618463-608.png]]
478 +
377 377  === 3.3.4 Compose the uplink payload ===
378 378  
379 379  (((
380 380  Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
381 -
382 -
383 383  )))
384 384  
385 385  (((
386 -(% style="color:#037691" %)**Examples: AT+DATAUP=0**
387 -
388 -
486 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0**
389 389  )))
390 390  
391 391  (((
... ... @@ -406,10 +406,8 @@
406 406  
407 407  [[image:1653269759169-150.png||height="513" width="716"]]
408 408  
507 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1**
409 409  
410 -(% style="color:#037691" %)**Examples: AT+DATAUP=1**
411 -
412 -
413 413  Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**Multiply UPLINKs**.
414 414  
415 415  Final Payload is
... ... @@ -416,53 +416,52 @@
416 416  
417 417  (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
418 418  
419 -1. PAYVER: Defined by AT+PAYVER
420 -1. PAYLOAD COUNT: Total how many uplinks of this sampling.
421 -1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
422 -1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
515 +1. Battery Info (2 bytes): Battery voltage
516 +1. PAYVER (1 byte): Defined by AT+PAYVER
517 +1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
518 +1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
519 +1. DATA: Valid value: max 6 bytes(US915 version here, Notice*!) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes
423 423  
424 -[[image:image-20220602155039-4.png]]
521 +[[image:1653269916228-732.png||height="433" width="711"]]
425 425  
426 426  
427 -So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
524 +So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA
428 428  
429 -DATA1=RETURN1 Valid Value + the first two of Valid value of RETURN10= **20 20 0a 33 90 41 02 aa**
526 +DATA1=RETURN1 Valid Value = (% style="background-color:green; color:white" %)20 20 0a 33 90 41
430 430  
431 -DATA2=3^^rd^^ ~~ 10^^th^^ byte of Valid value of RETURN10= **05 81 0a 20 20 20 20 2d**
528 +DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10=(% style="background-color:green; color:white" %) 02 aa 05 81 0a 20
432 432  
433 -DATA3=the rest of Valid value of RETURN10= **30**
530 +DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 = (% style="background-color:green; color:white" %)20 20 20 2d 30
434 434  
532 +Below are the uplink payloads:
435 435  
436 -(% style="color:red" %)Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:
534 +[[image:1653270130359-810.png]]
437 437  
438 - ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink.
439 439  
440 - * For AU915/AS923 bands, if UplinkDwell time=0, max 11 bytes for each uplink.
537 +(% style="color:red" %)**Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:**
441 441  
442 - * For US915 band, max 11 bytes for each uplink.
539 + ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
443 443  
444 - ~* For all other bands: max 51 bytes for each uplink.
541 + * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
445 445  
543 + * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
446 446  
447 -Below are the uplink payloads:
545 + ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
448 448  
449 -[[image:1654157178836-407.png]]
450 -
451 -
452 452  === 3.3.5 Uplink on demand ===
453 453  
454 -Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command.
549 +Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command.
455 455  
456 456  Downlink control command:
457 457  
458 -**0x08 command**: Poll an uplink with current command set in RS485-LN.
553 +[[0x08 command>>path:#downlink_08]]: Poll an uplink with current command set in RS485-BL.
459 459  
460 -**0xA8 command**: Send a command to RS485-LN and uplink the output from sensors.
555 +[[0xA8 command>>path:#downlink_A8]]: Send a command to RS485-BL and uplink the output from sensors.
461 461  
462 462  
463 463  
464 -1.
465 -11.
559 +1.
560 +11.
466 466  111. Uplink on Interrupt
467 467  
468 468  Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
... ... @@ -476,7 +476,7 @@
476 476  AT+INTMOD=3  Interrupt trigger by rising edge.
477 477  
478 478  
479 -1.
574 +1.
480 480  11. Uplink Payload
481 481  
482 482  |**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands**
... ... @@ -538,15 +538,15 @@
538 538  
539 539  * **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
540 540  
541 -1.
542 -11.
636 +1.
637 +11.
543 543  111. Common Commands:
544 544  
545 545  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
546 546  
547 547  
548 -1.
549 -11.
643 +1.
644 +11.
550 550  111. Sensor related commands:
551 551  
552 552  ==== Choose Device Type (RS485 or TTL) ====
... ... @@ -852,13 +852,13 @@
852 852  
853 853  
854 854  
855 -1.
950 +1.
856 856  11. Buttons
857 857  
858 858  |**Button**|**Feature**
859 859  |**RST**|Reboot RS485-BL
860 860  
861 -1.
956 +1.
862 862  11. +3V3 Output
863 863  
864 864  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -876,7 +876,7 @@
876 876  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
877 877  
878 878  
879 -1.
974 +1.
880 880  11. +5V Output
881 881  
882 882  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
... ... @@ -896,13 +896,13 @@
896 896  
897 897  
898 898  
899 -1.
994 +1.
900 900  11. LEDs
901 901  
902 902  |**LEDs**|**Feature**
903 903  |**LED1**|Blink when device transmit a packet.
904 904  
905 -1.
1000 +1.
906 906  11. Switch Jumper
907 907  
908 908  |**Switch Jumper**|**Feature**
... ... @@ -948,7 +948,7 @@
948 948  
949 949  
950 950  
951 -1.
1046 +1.
952 952  11. Common AT Command Sequence
953 953  111. Multi-channel ABP mode (Use with SX1301/LG308)
954 954  
... ... @@ -967,8 +967,8 @@
967 967  
968 968  ATZ
969 969  
970 -1.
971 -11.
1065 +1.
1066 +11.
972 972  111. Single-channel ABP mode (Use with LG01/LG02)
973 973  
974 974  AT+FDR   Reset Parameters to Factory Default, Keys Reserve
... ... @@ -1043,7 +1043,7 @@
1043 1043  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1044 1044  
1045 1045  
1046 -1.
1141 +1.
1047 1047  11. How to change the LoRa Frequency Bands/Region?
1048 1048  
1049 1049  User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
... ... @@ -1050,7 +1050,7 @@
1050 1050  
1051 1051  
1052 1052  
1053 -1.
1148 +1.
1054 1054  11. How many RS485-Slave can RS485-BL connects?
1055 1055  
1056 1056  The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
... ... @@ -1067,7 +1067,7 @@
1067 1067  
1068 1068  
1069 1069  
1070 -1.
1165 +1.
1071 1071  11. Why I can’t join TTN V3 in US915 /AU915 bands?
1072 1072  
1073 1073  It might about the channels mapping. Please see for detail.
1654157178836-407.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -179.9 KB
Content
1654157342174-798.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -31.9 KB
Content
image-20220602153621-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -22.2 KB
Content
image-20220602153621-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -22.3 KB
Content
image-20220602155039-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0