10 = 1.  Introduction =
11
12 == 1.1 ​ What is NSPH01 Soil pH Sensor ==
13
14
15 (((
16 The Dragino NSPH01 is a (% style="color:blue" %)**NB-IoT soil pH sensor**(%%) for IoT of Agriculture. It is designed to measure the soil pH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
17 )))
18
19 (((
20 NSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:blue" %)pH (%%)**with high accuracy and stable value. The NSPH01 probe can be buried into soil for long time use.
21 )))
22
23 (((
24 NarrowBand-Internet of Things (NB-IoT) is a standards-based low power wide area (LPWA) technology developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity and spectrum efficiency, especially in deep coverage.
25 )))
26
27 (((
28 NSPH01 supports different uplink methods include (% style="color:blue" %)**TCP,MQTT,UDP and CoAP  **(%%)for different application requirement.
29 )))
30
31 (((
32 NSPH01 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method)
33 )))
34
35 (((
36 To use NSPH01, user needs to check if there is NB-IoT coverage in the installation area and with the bands NSPH01 supports. If the local operator supports it, user needs to get a (% style="color:blue" %)**NB-IoT SIM card** (%%)from local operator and install NSPH01 to get NB-IoT network connection.
37 )))
38
39
40 [[image:image-20220907153151-1.png]]
41
42
43 [[image:M_K`YF9`CAYAE\@}3T]FHT$9.png]]
44
45
46 == 1.2  Features ==
47
48
49 * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD
50 * Monitor soil pH with temperature compensation.
51 * Monitor soil temperature
52 * pH and Temperature alarm function
53 * Monitor Battery Level
54 * Support pH calibration by end user
55 * Uplink on periodically
56 * Downlink to change configure
57 * IP66 Waterproof Enclosure
58 * IP68 rate for the Sensor Probe
59 * Ultra-Low Power consumption
60 * AT Commands to change parameters
61 * Micro SIM card slot
62 * 8500mAh Battery for long term use
63
64
65 == 1.3  Specification ==
66
67
68 (% style="color:#037691" %)**Common DC Characteristics:**
69
70 * Supply Voltage: 2.1v ~~ 3.6v
71 * Operating Temperature: -40 ~~ 85°C
72
73 (% style="color:#037691" %)**NB-IoT Spec:**
74
75 * B1 @H-FDD: 2100MHz
76 * B3 @H-FDD: 1800MHz
77 * B8 @H-FDD: 900MHz
78 * B5 @H-FDD: 850MHz
79 * B20 @H-FDD: 800MHz
80 * B28 @H-FDD: 700MHz
81
82
83 == 1.4  Probe Specification ==
84
85
86 (% style="color:#037691" %)**Soil pH:**
87
88 * Range: 3 ~~ 10 pH
89 * Resolution: 0.01 pH
90 * Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen)
91 * Temperature Compensation Range: 0 ~~ 50℃
92 * IP68 Protection
93 * Length: 3.5 meters
94
95 (% style="color:#037691" %)**Soil Temperature:**
96
97 * Range -40℃~85℃
98 * Resolution: 0.1℃
99 * Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others)
100 * IP68 Protection
101 * Length: 3.5 meters
102
103
104 == 1.5  ​Applications ==
105
106
107 * Smart Agriculture
108
109
110 == 1.6  Pin mapping and power on ==
111
112
113 [[image:image-20220907153300-2.png]]
114
115
116 = 2.  Use NSPH01 to communicate with IoT Server =
117
118 == 2.1  How it works ==
119
120
121 The NSPH01 is equipped with a NB-IoT module, the pre-loaded firmware in NSPH01 will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by NSPH01.
122
123 The diagram below shows the working flow in default firmware of NSPH01:
124
125
126 [[image:image-20220907153416-3.png]]
127
128
129 == 2.2 ​ Configure the NSPH01 ==
130
131 === 2.2.1 Test Requirement ===
132
133
134 To use NSPH01 in the field, make sure meet below requirements:
135
136 * Your local operator has already distributed a NB-IoT Network there.
137 * The local NB-IoT network used the band that NSPH01 supports.
138 * Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
139
140 Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.  The NSPH01 will use** CoAP(120.24.4.116:5683) **or raw **UDP(120.24.4.116:5601)** or **MQTT(120.24.4.116:1883)**or **TCP(120.24.4.116:5600)**protocol to send data to the test server.
141
142
143 [[image:image-20220907153445-4.png]]
144
145
146 === 2.2.2 Insert SIM card ===
147
148
149 User need to take out the NB-IoT module and insert the SIM card like below. ((% style="color:red" %) Pay attention to the direction(%%))
150
151
152 [[image:image-20220907153505-5.png]]
153
154
155 === 2.2.3 Connect USB – TTL to NSPH01 to configure it ===
156
157
158 User need to configure NSPH01 via serial port to set the (% style="color:blue" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NSPH01 support AT Commands, user can use a USB to TTL adapter to connect to NSPH01 and use AT Commands to configure it, as below.
159
160
161 (% style="color:blue" %)**Connection:**
162
163 **~ (% style="background-color:yellow" %) USB TTL GND <~-~-~-~->  GND(%%)**
164
165 **~ (% style="background-color:yellow" %) USB TTL TXD  <~-~-~-~->  UART_RXD(%%)**
166
167 **~ (% style="background-color:yellow" %) USB TTL RXD  <~-~-~-~->  UART_TXD(%%)**
168
169
170 In the PC, use below serial tool settings:
171
172 * Baud:  (% style="color:green" %)**9600**
173 * Data bits:**  (% style="color:green" %)8(%%)**
174 * Stop bits:  (% style="color:green" %)**1**
175 * Parity:  (% style="color:green" %)**None**
176 * Flow Control: (% style="color:green" %)**None**
177
178 Make sure the switch is in FLASH position, then power on device by connecting the jumper on NSPH01. NSPH01 will output system info once power on as below, we can enter the (% style="color:green" %)**password: 12345678**(%%) to access AT Command input.
179
180
181 [[image:image-20220912144017-1.png]]
182
183
184 (% style="color:red" %)**Note: the valid AT Commands can be found at:**(%%)**  **[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
185
186
187 === 2.2.4 Use CoAP protocol to uplink data ===
188
189
190 (% style="color:red" %)**Note: if you don't have CoAP server, you can refer this link to set up one:**(%%)** **[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]
191
192
193 (% style="color:blue" %)**Use below commands:**
194
195 * (% style="color:#037691" %)**AT+PRO=1**                         (%%) ~/~/  Set to use CoAP protocol to uplink
196 * (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5683   ** (%%) ~/~/  to set CoAP server address and port
197 * (% style="color:#037691" %)**AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** (%%) ~/~/  Set COAP resource path
198
199 For parameter description, please refer to AT command set
200
201
202 [[image:image-20220907153551-7.png||height="502" width="740"]]
203
204
205 After configure the server address and (% style="color:green" %)**reset the device (via AT+ATZ )**(%%), NSPH01 will start to uplink sensor values to CoAP server.
206
207
208 [[image:image-20220907153612-8.png||height="529" width="729"]]
209
210
211 === 2.2.5 Use UDP protocol to uplink data(Default protocol) ===
212
213
214 This feature is supported since firmware version v1.0.1
215
216 * (% style="color:blue" %)**AT+PRO=2   ** (%%) ~/~/  Set to use UDP protocol to uplink
217 * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5601   ** (%%) ~/~/  to set UDP server address and port
218 * (% style="color:blue" %)**AT+CFM=1       ** (%%) ~/~/  If the server does not respond, this command is unnecessar
219
220 [[image:image-20220907153643-9.png||height="401" width="734"]]
221
222
223 [[image:image-20220907153703-10.png||height="309" width="738"]]
224
225
226 === 2.2.6 Use MQTT protocol to uplink data ===
227
228
229 This feature is supported since firmware version v110
230
231 * (% style="color:blue" %)**AT+PRO=3   ** (%%) ~/~/ Set to use MQTT protocol to uplink
232 * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,1883   ** (%%) ~/~/ Set MQTT server address and port
233 * (% style="color:blue" %)**AT+CLIENT=CLIENT       ** (%%) ~/~/ Set up the CLIENT of MQTT
234 * (% style="color:blue" %)**AT+UNAME=UNAME                               **(%%)~/~/ Set the username of MQTT
235 * (% style="color:blue" %)**AT+PWD=PWD                                        **(%%)~/~/ Set the password of MQTT
236 * (% style="color:blue" %)**AT+PUBTOPIC=NSE01_PUB                    **(%%)~/~/ Set the sending topic of MQTT
237 * (% style="color:blue" %)**AT+SUBTOPIC=NSE01_SUB          ** (%%) ~/~/ Set the subscription topic of MQTT
238
239 [[image:image-20220907153739-11.png||height="491" width="764"]]
240
241
242 [[image:image-20220907153751-12.png||height="555" width="769"]]
243
244
245 MQTT protocol has a much higher power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval.
246
247
248 === 2.2.7 Use TCP protocol to uplink data ===
249
250
251 This feature is supported since firmware version v110
252
253 * (% style="color:blue" %)**AT+PRO=4   ** (%%) ~/~/ Set to use TCP protocol to uplink
254 * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5600   ** (%%) ~/~/ to set TCP server address and port
255
256 [[image:image-20220907153818-13.png||height="486" width="668"]]
257
258
259 [[image:image-20220907153827-14.png||height="236" width="684"]]
260
261
262 === 2.2.8 Change Update Interval ===
263
264
265 Users can use the below command to change the **uplink interval**.
266
267 * (% style="color:blue" %)**AT+TDC=7200      ** (%%) ~/~/ Set Update Interval to 7200s (2 hour)
268
269 (% style="color:red" %)**NOTE: By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).**
270
271
272 == 2.3  Uplink Payload ==
273
274
275 In this mode, uplink payload includes 87 bytes in total by default.
276
277 Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded.
278
279 (% border="1.5" style="background-color:#ffffcc; color:green; width:520px" %)
280 |=(% scope="row" style="width: 50px;" %)**Size(bytes)**|(% style="width:40px" %)**8**|(% style="width:20px" %)**2**|(% style="width:25px" %)**2**|(% style="width:60px" %)**1**|(% style="width:20px" %)**1**|(% style="width:40px" %)**1**|(% style="width:40px" %)**2**|(% style="width:50px" %)**2**|(% style="width:50px" %)**4**|(% style="width:50px" %)**2**|(% style="width:35px" %)**2**|(% style="width:40px" %)**4**
281 |=(% style="width: 96px;" %)**Value**|(% style="width:83px" %)Device ID|(% style="width:44px" %)Ver|(% style="width:42px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:57px" %)MOD|(% style="width:80px" %)Interrupt|(% style="width:69px" %)Soil PH|(% style="width:134px" %)Soil Temperature|(% style="width:98px" %)Time stamp|(% style="width:134px" %)Soil Temperature|(% style="width:68px" %)Soil PH|(% style="width:125px" %)Time stamp  .....
282
283 If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NSPH01 uplink data.
284
285 [[image:image-20220907153902-15.png||height="581" width="804"]]
286
287
288 (((
289 The payload is ASCII string, representative same HEX:
290 )))
291
292 (((
293
294 )))
295
296 (((
297 **0x (% style="color:red" %)__f868411056754138__  (% style="color:blue" %)__0064 __ (% style="color:green" %)__0c78__  (% style="color:#00b0f0" %)__17__  (% style="color:#7030a0" %)__01__  (% style="color:#d60093" %)__00__  (% style="color:#a14d07" %)__0225 __ (% style="color:#0020b0" %) __010b__  (% style="color:#420042" %)__6315537b__  (% style="color:#663300" %)//__010b0226631550fb__  __010e022663154d77  01110225631549f1  011502246315466b  01190223631542e5  011d022163153f62  011e022163153bde 011e022163153859__//(%%)**
298 )))
299
300 (((
301
302
303 **where:**
304 )))
305
306 * (% style="color:#037691" %)**Device ID:**(%%)** **0xf868411056754138 = f868411056754138
307
308 * (% style="color:#037691" %)**Version:**  (%%) 0x0064=100=1.0.0
309
310 * (% style="color:#037691" %)**BAT:**   (%%) 0x0c78 = 3192 mV = 3.192V
311
312 * (% style="color:#037691" %)**Singal:** (%%)0x17 = 23
313
314 * (% style="color:#037691" %)**Mod:** (%%) 0x01 = 1
315
316 * (% style="color:#037691" %)**Interrupt:**(%%) 0x00= 0
317
318 * (% style="color:#037691" %)**Soil PH:** (%%) 0x0225= 549 = 5.49
319
320 * (% style="color:#037691" %)**Soil Temperature:**(%%) 0x010b =267=26.7 °C
321
322 * (% style="color:#037691" %)**Time stamp :**   (%%) 0x6315537b =1662342011  ([[Unix Epoch Time>>url:http://www.epochconverter.com/]])
323
324 * (% style="color:#037691" %)**Soil Temperature,Soil PH,Time stamp : **(%%) 010b0226631550fb
325
326 * (% style="color:#037691" %)**8 sets of recorded data:**(%%) Temperature,Soil PH,Time stamp :  010e022663154d77,.......
327
328 == 2.4  Payload Explanation and Sensor Interface ==
329
330 === 2.4.1  Device ID ===
331
332
333 By default, the Device ID equal to the last 15 bits of IMEI.
334
335 User can use (% style="color:blue" %)**AT+DEUI** (%%)to set Device ID
336
337
338 **Example:**
339
340 AT+DEUI=868411056754138
341
342 The Device ID is stored in a none-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID.
343
344
345 === 2.4.2  Version Info ===
346
347
348 Specify the software version: 0x64=100, means firmware version 1.00.
349
350 For example: 0x00 64 : this device is NSPH01 with firmware version 1.0.0.
351
352
353 === 2.4.3  Battery Info ===
354
355
356 Check the battery voltage for NSPH01.
357
358 Ex1: 0x0B45 = 2885mV
359
360 Ex2: 0x0B49 = 2889mV
361
362
363 === 2.4.4  Signal Strength ===
364
365
366 NB-IoT Network signal Strength.
367
368 **Ex1: 0x1d = 29**
369
370 **0**  -113dBm or less
371
372 **1**  -111dBm
373
374 **2...30** -109dBm... -53dBm
375
376 **31**   -51dBm or greater
377
378 **99**    Not known or not detectable
379
380
381 === 2.4.5  Soil PH ===
382
383
384 Get the PH content of the soil. The value range of the register is 300-1000(Decimal), divide this value by 100 to get the percentage of PH in the soil.
385
386 For example, if the data you get from the register is (% style="color:blue" %)**__0x05 0xDC__**(%%), the PH content in the soil is
387
388 (% style="color:blue" %)**0229(H) = 549(D) /100 = 5.49.**
389
390
391 === 2.4.6  Soil Temperature ===
392
393
394 Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is (% style="color:blue" %)**__0x09 0xEC__**(%%), the temperature content in the soil is
395
396
397 **Example**:
398
399 If payload is 0105H: ((0x0105 & 0x8000)>>15 === 0),temp = 0105(H)/10 = 26.1 °C
400
401 If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/10 = -12.9 °C
402
403
404 === 2.4.7  Timestamp ===
405
406
407 Time stamp : 0x6315537b =1662342011
408
409 Convert Unix timestamp to time 2022-9-5 9:40:11.
410
411
412 === 2.4.8  Digital Interrupt ===
413
414
415 Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NSPH01 will send a packet to the server.
416
417 The command is:
418
419 (% style="color:blue" %)**AT+INTMOD=3 ** (%%) ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.**
420
421 The lower four bits of this data field shows if this packet is generated by interrupt or not. Click here for the hardware and software set up.
422
423
424 **Example:**
425
426 0x(00): Normal uplink packet.
427
428 0x(01): Interrupt Uplink Packet.
429
430
431 === 2.4.9  ​+5V Output ===
432
433
434 NSPH01 will enable +5V output before all sampling and disable the +5v after all sampling. 
435
436 The 5V output time can be controlled by AT Command.
437
438 (% style="color:blue" %)**AT+5VT=1000**
439
440 Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.** **
441
442
443 == 2.5  Downlink Payload ==
444
445
446 By default, NSPH01 prints the downlink payload to console port.
447
448 [[image:image-20220907154636-17.png]]
449
450
451 (% style="color:blue" %)**Examples:**
452
453 * (% style="color:#037691" %)** Set TDC**
454
455 If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
456
457 Payload:    01 00 00 1E    TDC=30S
458
459 Payload:    01 00 00 3C    TDC=60S
460
461 * (% style="color:#037691" %)** Reset**
462
463 If payload = 0x04FF, it will reset the NSPH01
464
465 * (% style="color:#037691" %)** INTMOD**
466
467 Downlink Payload: 06000003, Set AT+INTMOD=3
468
469
470 == 2.6  ​LED Indicator ==
471
472
473 The NSPH01 has an internal LED which is to show the status of different state.
474
475 * When power on, NSPH01 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe)
476 * Then the LED will be on for 1 second means device is boot normally.
477 * After NSPH01 join NB-IoT network. The LED will be ON for 3 seconds.
478 * For each uplink probe, LED will be on for 500ms.
479
480 == 2.7  Installation and Maintain ==
481
482 === 2.7.1  Before measurement ===
483
484
485 If the NSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
486
487
488 === 2.7.2  Measurement ===
489
490
491 (% style="color:#037691" %)**Measurement the soil surface:**
492
493
494 [[image:image-20220907154700-18.png]] ​
495
496 Choose the proper measuring position. Split the surface soil according to the measured deep.
497
498 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things.
499
500 Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
501
502 Put soil over the probe after insert. And start to measure.
503
504
505 (% style="color:#037691" %)**Measurement inside soil:**
506
507 Dig a hole with diameter > 20CM.
508
509 Insert the probe inside, method like measure the surface.
510
511
512 === 2.7.3  Maintain Probe ===
513
514
515 1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
516 1. After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
517 1. Probe reference electrode is also no strong, need to avoid strong force or hitting.
518 1. User should keep reference electrode wet while not use.
519 1. Avoid the probes to touch oily matter. Which will cause issue in accuracy.
520 1. The probe is IP68 can be put in water.
521
522 == 2.8  PH and Temperature alarm function ==
523
524
525 (% style="color:#037691" %)**➢ AT Command:**
526
527 (% style="color:blue" %)**AT+ PHALARM=min,max**
528
529 ² When min=3, and max≠0, Alarm higher than max
530
531 ² When min≠0, and max=0, Alarm lower than min
532
533 ² When min≠0 and max≠0, Alarm higher than max or lower than min
534
535
536 (% style="color:blue" %)**Example:**
537
538 AT+ PHALARM =5,8  ~/~/ Alarm when PH lower than 5.
539
540 AT+ TEMPALARM=min,max
541
542 ² When min=0, and max≠0, Alarm higher than max
543
544 ² When min≠0, and max=0, Alarm lower than min
545
546 ² When min≠0 and max≠0, Alarm higher than max or lower than min
547
548
549 (% style="color:blue" %)**Example:**
550
551 AT+ TEMPALARM=20,30  ~/~/ Alarm when temperature lower than 20.
552
553
554 == 2.9  Set the number of data to be uploaded and the recording time ==
555
556
557 (% style="color:#037691" %)**➢ AT Command:**
558
559 * (% style="color:blue" %)**AT+TR=900**     (%%) ~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
560 * (% style="color:blue" %)**AT+NOUD=8**     (%%) ~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
561
562 The diagram below explains the relationship between TR, NOUD, and TDC more clearly**:**
563
564 [[image:image-20221009000933-1.png||height="750" width="1043"]]
565
566
567 == 2.10  Read or Clear cached data ==
568
569
570 (% style="color:#037691" %)**➢ AT Command:**
571
572 * (% style="color:blue" %)**AT+CDP**        (%%) ~/~/  Read cached data
573 * (% style="color:blue" %)**AT+CDP=0**    (%%) ~/~/  Clear cached data
574
575 [[image:image-20220907154700-19.png]]
576
577
578 == 2.11  Calibration ==
579
580
581 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
582
583 After stable, user can use below command to calibrate.
584
585
586 [[image:image-20220907154700-20.png]] ​
587
588
589 == 2.12  ​Firmware Change Log ==
590
591
592 Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/1tv07fro2pvjqj8/AAD-2wbfGfluTZfh38fQqdA_a?dl=0>>https://www.dropbox.com/sh/1tv07fro2pvjqj8/AAD-2wbfGfluTZfh38fQqdA_a?dl=0]]
593
594 Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]]
595
596
597 == 2.13 Battery & Power Consumption ==
598
599
600 NSPH01 uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
601
602 [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
603
604
605 = 3. ​ Access NB-IoT Module =
606
607
608 Users can directly access the AT command set of the NB-IoT module.
609
610 The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 
611
612
613 [[image:image-20220907154700-23.png]]
614
615
616
617 = 4.  Using the AT Commands =
618
619 == 4.1  Access AT Commands ==
620
621
622 See this link for detail:  [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
623
624 AT+<CMD>?  : Help on <CMD>
625
626 AT+<CMD>         : Run <CMD>
627
628 AT+<CMD>=<value> : Set the value
629
630 AT+<CMD>=?  : Get the value
631
632
633 (% style="color:#037691" %)**General Commands**      
634
635 AT  : Attention       
636
637 AT?  : Short Help     
638
639 ATZ  : MCU Reset    
640
641 AT+TDC  : Application Data Transmission Interval
642
643 AT+CFG  : Print all configurations
644
645 AT+CFGMOD           : Working mode selection
646
647 AT+INTMOD            : Set the trigger interrupt mode
648
649 AT+5VT  : Set extend the time of 5V power  
650
651 AT+PRO  : Choose agreement
652
653 AT+RXDL  : Extend the sending and receiving time
654
655 AT+SERVADDR  : Server Address
656
657 AT+TR      : Get or Set record time"
658
659 AT+APN     : Get or set the APN
660
661 AT+FBAND   : Get or Set whether to automatically modify the frequency band
662
663 AT+DNSCFG  : Get or Set DNS Server
664
665 AT+GETSENSORVALUE   : Returns the current sensor measurement
666
667 AT+NOUD      : Get or Set the number of data to be uploaded
668
669 AT+CDP     : Read or Clear cached data
670
671 AT+TEMPALARM      : Get or Set alarm of temp
672
673 AT+PHALARM     : Get or Set alarm of PH
674
675 AT+ PHCAL  : calibrate PH value
676
677
678 (% style="color:#037691" %)**COAP Management**      
679
680 AT+URI            : Resource parameters
681
682
683 (% style="color:#037691" %)**UDP Management**
684
685 AT+CFM          : Upload confirmation mode (only valid for UDP)
686
687
688 (% style="color:#037691" %)**MQTT Management**
689
690 AT+CLIENT               : Get or Set MQTT client
691
692 AT+UNAME  : Get or Set MQTT Username
693
694 AT+PWD                  : Get or Set MQTT password
695
696 AT+PUBTOPIC  : Get or Set MQTT publish topic
697
698 AT+SUBTOPIC  : Get or Set MQTT subscription topic
699
700
701 (% style="color:#037691" %)**Information**          
702
703 AT+FDR  : Factory Data Reset
704
705 AT+PWORD  : Serial Access Password
706
707
708 = ​5.  FAQ =
709
710 == 5.1 ​ How to Upgrade Firmware ==
711
712
713 User can upgrade the firmware for 1) bug fix, 2) new feature release.
714
715 Please see this link for how to upgrade:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]
716
717 (% style="color:red" %)**Notice, NSPH01 and LSPH01 share the same mother board. They use the same connection and method to update.**
718
719
720 == 5.2  Can I calibrate NSPH01 to different soil types? ==
721
722
723 NSPH01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]].
724
725
726 = 6.  Trouble Shooting =
727
728 == 6.1  ​Connection problem when uploading firmware ==
729
730
731 **Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]
732
733
734 == 6.2  AT Command input doesn't work ==
735
736
737 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string.
738
739
740 == 6.3 Not able to connect to NB-IoT network and keep showing "Signal Strength:99". ==
741
742
743 This means sensor is trying to join the NB-IoT network but fail. Please see this link for **//[[trouble shooting for signal strenght:99>>doc:Main.CSQ\:99,99.WebHome]]//**.
744
745
746 = 7. ​ Order Info =
747
748
749 Part Number**:** NSPH01
750
751
752 = 8.  Packing Info =
753
754
755 **Package Includes**:
756
757 * NSPH01 NB-IoT pH Sensor x 1
758 * External antenna x 1
759
760 **Dimension and weight**:
761
762 * Device Size: cm
763 * Device Weight: g
764 * Package Size / pcs : cm
765 * Weight / pcs : g
766
767
768 = 9.  Support =
769
770
771 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
772 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
773
774