Changes for page NSPH01-NB-IoT Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/03/30 17:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,6 +9,7 @@ 9 9 10 10 = 1. Introduction = 11 11 12 + 12 12 == 1.1 What is NSPH01 Soil pH Sensor == 13 13 14 14 ... ... @@ -31,6 +31,7 @@ 31 31 [[image:M_K`YF9`CAYAE\@}3T]FHT$9.png]] 32 32 33 33 35 + 34 34 == 1.2 Features == 35 35 36 36 ... ... @@ -49,6 +49,8 @@ 49 49 * Micro SIM card slot 50 50 * 8500mAh Battery for long term use 51 51 54 + 55 + 52 52 == 1.3 Specification == 53 53 54 54 ... ... @@ -59,13 +59,15 @@ 59 59 60 60 (% style="color:#037691" %)**NB-IoT Spec:** 61 61 62 -* B1 @H-FDD: 2100MHz 63 -* B3 @H-FDD: 1800MHz 64 -* B8 @H-FDD: 900MHz 65 -* B5 @H-FDD: 850MHz 66 -* B20 @H-FDD: 800MHz 67 -* B28 @H-FDD: 700MHz 66 +* - B1 @H-FDD: 2100MHz 67 +* - B3 @H-FDD: 1800MHz 68 +* - B8 @H-FDD: 900MHz 69 +* - B5 @H-FDD: 850MHz 70 +* - B20 @H-FDD: 800MHz 71 +* - B28 @H-FDD: 700MHz 68 68 73 + 74 + 69 69 == 1.4 Probe Specification == 70 70 71 71 ... ... @@ -86,11 +86,15 @@ 86 86 * IP68 Protection 87 87 * Length: 3.5 meters 88 88 95 + 96 + 89 89 == 1.5 Applications == 90 90 91 91 92 92 * Smart Agriculture 93 93 102 + 103 + 94 94 == 1.6 Pin mapping and power on == 95 95 96 96 ... ... @@ -100,6 +100,7 @@ 100 100 101 101 = 2. Use NSPH01 to communicate with IoT Server = 102 102 113 + 103 103 == 2.1 How it works == 104 104 105 105 ... ... @@ -114,6 +114,7 @@ 114 114 115 115 == 2.2 Configure the NSPH01 == 116 116 128 + 117 117 === 2.2.1 Test Requirement === 118 118 119 119 ... ... @@ -129,6 +129,7 @@ 129 129 [[image:image-20220907153445-4.png]] 130 130 131 131 144 + 132 132 === 2.2.2 Insert SIM card === 133 133 134 134 ... ... @@ -138,6 +138,7 @@ 138 138 [[image:image-20220907153505-5.png]] 139 139 140 140 154 + 141 141 === 2.2.3 Connect USB – TTL to NSPH01 to configure it === 142 142 143 143 ... ... @@ -170,6 +170,7 @@ 170 170 (% style="color:red" %)**Note: the valid AT Commands can be found at:**(%%)** **[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 171 171 172 172 187 + 173 173 === 2.2.4 Use CoAP protocol to uplink data === 174 174 175 175 ... ... @@ -194,6 +194,7 @@ 194 194 [[image:image-20220907153612-8.png||height="529" width="729"]] 195 195 196 196 212 + 197 197 === 2.2.5 Use UDP protocol to uplink data(Default protocol) === 198 198 199 199 ... ... @@ -209,6 +209,7 @@ 209 209 [[image:image-20220907153703-10.png||height="309" width="738"]] 210 210 211 211 228 + 212 212 === 2.2.6 Use MQTT protocol to uplink data === 213 213 214 214 ... ... @@ -231,6 +231,7 @@ 231 231 MQTT protocol has a much higher power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval. 232 232 233 233 251 + 234 234 === 2.2.7 Use TCP protocol to uplink data === 235 235 236 236 ... ... @@ -245,6 +245,7 @@ 245 245 [[image:image-20220907153827-14.png||height="236" width="684"]] 246 246 247 247 266 + 248 248 === 2.2.8 Change Update Interval === 249 249 250 250 ... ... @@ -255,6 +255,7 @@ 255 255 (% style="color:red" %)**NOTE: By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).** 256 256 257 257 277 + 258 258 == 2.3 Uplink Payload == 259 259 260 260 ... ... @@ -311,8 +311,11 @@ 311 311 312 312 * (% style="color:#037691" %)**8 sets of recorded data:**(%%) Temperature,Soil PH,Time stamp : 010e022663154d77,....... 313 313 334 + 335 + 314 314 == 2.4 Payload Explanation and Sensor Interface == 315 315 338 + 316 316 === 2.4.1 Device ID === 317 317 318 318 ... ... @@ -328,6 +328,7 @@ 328 328 The Device ID is stored in a none-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID. 329 329 330 330 354 + 331 331 === 2.4.2 Version Info === 332 332 333 333 ... ... @@ -336,6 +336,7 @@ 336 336 For example: 0x00 64 : this device is NSPH01 with firmware version 1.0.0. 337 337 338 338 363 + 339 339 === 2.4.3 Battery Info === 340 340 341 341 ... ... @@ -346,6 +346,7 @@ 346 346 Ex2: 0x0B49 = 2889mV 347 347 348 348 374 + 349 349 === 2.4.4 Signal Strength === 350 350 351 351 ... ... @@ -364,6 +364,7 @@ 364 364 **99** Not known or not detectable 365 365 366 366 393 + 367 367 === 2.4.5 Soil PH === 368 368 369 369 ... ... @@ -374,6 +374,7 @@ 374 374 (% style="color:blue" %)**0229(H) = 549(D) /100 = 5.49.** 375 375 376 376 404 + 377 377 === 2.4.6 Soil Temperature === 378 378 379 379 ... ... @@ -387,6 +387,7 @@ 387 387 If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/10 = -12.9 °C 388 388 389 389 418 + 390 390 === 2.4.7 Timestamp === 391 391 392 392 ... ... @@ -395,6 +395,7 @@ 395 395 Convert Unix timestamp to time 2022-9-5 9:40:11. 396 396 397 397 427 + 398 398 === 2.4.8 Digital Interrupt === 399 399 400 400 ... ... @@ -414,6 +414,7 @@ 414 414 0x(01): Interrupt Uplink Packet. 415 415 416 416 447 + 417 417 === 2.4.9 +5V Output === 418 418 419 419 ... ... @@ -426,6 +426,7 @@ 426 426 Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.** ** 427 427 428 428 460 + 429 429 == 2.5 Downlink Payload == 430 430 431 431 ... ... @@ -453,6 +453,7 @@ 453 453 Downlink Payload: 06000003, Set AT+INTMOD=3 454 454 455 455 488 + 456 456 == 2.6 LED Indicator == 457 457 458 458 ... ... @@ -463,8 +463,11 @@ 463 463 * After NSPH01 join NB-IoT network. The LED will be ON for 3 seconds. 464 464 * For each uplink probe, LED will be on for 500ms. 465 465 499 + 500 + 466 466 == 2.7 Installation and Maintain == 467 467 503 + 468 468 === 2.7.1 Before measurement === 469 469 470 470 ... ... @@ -471,6 +471,7 @@ 471 471 If the NSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 472 472 473 473 510 + 474 474 === 2.7.2 Measurement === 475 475 476 476 ... ... @@ -495,6 +495,7 @@ 495 495 Insert the probe inside, method like measure the surface. 496 496 497 497 535 + 498 498 === 2.7.3 Maintain Probe === 499 499 500 500 ... ... @@ -505,6 +505,8 @@ 505 505 1. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 506 506 1. The probe is IP68 can be put in water. 507 507 546 + 547 + 508 508 == 2.8 PH and Temperature alarm function == 509 509 510 510 ... ... @@ -537,6 +537,7 @@ 537 537 AT+ TEMPALARM=20,30 ~/~/ Alarm when temperature lower than 20. 538 538 539 539 580 + 540 540 == 2.9 Set the number of data to be uploaded and the recording time == 541 541 542 542 ... ... @@ -550,6 +550,7 @@ 550 550 [[image:image-20221009000933-1.png||height="750" width="1043"]] 551 551 552 552 594 + 553 553 == 2.10 Read or Clear cached data == 554 554 555 555 ... ... @@ -561,6 +561,7 @@ 561 561 [[image:image-20220907154700-19.png]] 562 562 563 563 606 + 564 564 == 2.11 Calibration == 565 565 566 566 ... ... @@ -572,6 +572,7 @@ 572 572 [[image:image-20220907154700-20.png]] 573 573 574 574 618 + 575 575 == 2.12 Firmware Change Log == 576 576 577 577 ... ... @@ -580,14 +580,64 @@ 580 580 Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]] 581 581 582 582 583 -== 2.13 Battery & Power Consumption == 584 584 628 +== 2.13 Battery Analysis == 585 585 586 -NSPH01 uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 587 587 588 - [[**BatteryInfo & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]].631 +=== 2.13.1 Battery Type === 589 589 590 590 634 +The NSPH01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 635 + 636 +The battery is designed to last for several years depends on the actually use environment and update interval. 637 + 638 +The battery-related documents as below: 639 + 640 +* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 641 +* [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 642 +* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 643 + 644 +[[image:image-20220907154700-21.png]] 645 + 646 + 647 + 648 +=== 2.13.2 Power consumption Analyze === 649 + 650 + 651 +Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 652 + 653 +Instruction to use as below: 654 + 655 +(% style="color:blue" %)**Step 1: **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 656 + 657 +(% style="color:blue" %)**Step 2: **(%%) Open it and choose 658 + 659 +* Product Model 660 +* Uplink Interval 661 +* Working Mode 662 + 663 +And the Life expectation in difference case will be shown on the right. 664 + 665 + 666 +[[image:image-20220907154700-22.jpeg]] 667 + 668 + 669 + 670 + 671 +=== 2.13.3 Battery Note === 672 + 673 + 674 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 675 + 676 + 677 + 678 +=== 2.13.4 Replace the battery === 679 + 680 + 681 +The default battery pack of NSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 682 + 683 + 684 + 591 591 = 3. Access NB-IoT Module = 592 592 593 593 ... ... @@ -600,8 +600,10 @@ 600 600 601 601 602 602 697 + 603 603 = 4. Using the AT Commands = 604 604 700 + 605 605 == 4.1 Access AT Commands == 606 606 607 607 ... ... @@ -691,8 +691,10 @@ 691 691 AT+PWORD : Serial Access Password 692 692 693 693 790 + 694 694 = 5. FAQ = 695 695 793 + 696 696 == 5.1 How to Upgrade Firmware == 697 697 698 698 ... ... @@ -703,6 +703,7 @@ 703 703 (% style="color:red" %)**Notice, NSPH01 and LSPH01 share the same mother board. They use the same connection and method to update.** 704 704 705 705 804 + 706 706 == 5.2 Can I calibrate NSPH01 to different soil types? == 707 707 708 708 ... ... @@ -709,8 +709,10 @@ 709 709 NSPH01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]]. 710 710 711 711 811 + 712 712 = 6. Trouble Shooting = 713 713 814 + 714 714 == 6.1 Connection problem when uploading firmware == 715 715 716 716 ... ... @@ -717,6 +717,7 @@ 717 717 **Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]] 718 718 719 719 821 + 720 720 == 6.2 AT Command input doesn't work == 721 721 722 722 ... ... @@ -723,6 +723,7 @@ 723 723 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string. 724 724 725 725 828 + 726 726 = 7. Order Info = 727 727 728 728 ... ... @@ -745,6 +745,8 @@ 745 745 * Package Size / pcs : cm 746 746 * Weight / pcs : g 747 747 851 + 852 + 748 748 = 9. Support = 749 749 750 750