Changes for page NSPH01-NB-IoT Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/03/30 17:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,8 +61,6 @@ 61 61 * Micro SIM card slot 62 62 * 8500mAh Battery for long term use 63 63 64 - 65 - 66 66 == 1.3 Specification == 67 67 68 68 ... ... @@ -80,8 +80,6 @@ 80 80 * B20 @H-FDD: 800MHz 81 81 * B28 @H-FDD: 700MHz 82 82 83 - 84 - 85 85 == 1.4 Probe Specification == 86 86 87 87 ... ... @@ -102,15 +102,11 @@ 102 102 * IP68 Protection 103 103 * Length: 3.5 meters 104 104 105 - 106 - 107 107 == 1.5 Applications == 108 108 109 109 110 110 * Smart Agriculture 111 111 112 - 113 - 114 114 == 1.6 Pin mapping and power on == 115 115 116 116 ... ... @@ -280,9 +280,9 @@ 280 280 281 281 Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded. 282 282 283 -(% border="1 .5" style="background-color:#ffffcc;color:green;width:520px" %)284 -| =(% scope="row" style="width:;" %)**Size(bytes)**|(% style="width:40px" %)**8**|(% style="width:20px" %)**2**|(% style="width:25px" %)**2**|(% style="width:60px" %)**1**|(% style="width:20px" %)**1**|(% style="width:40px" %)**1**|(% style="width:40px" %)**2**|(% style="width:50px" %)**2**|(% style="width:50px" %)**4**|(% style="width:50px" %)**2**|(% style="width:35px" %)**2**|(% style="width:40px" %)**4**285 -| =(% style="width:;" %)**Value**|(% style="width:83px" %)Device ID|(% style="width:44px" %)Ver|(% style="width:42px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:57px" %)MOD|(% style="width:80px" %)Interrupt|(% style="width:69px" %)Soil PH|(% style="width:134px" %)Soil Temperature|(% style="width:98px" %)Time stamp|(% style="width:134px" %)Soil Temperature|(% style="width:68px" %)Soil PH|(% style="width:125px" %)Time stamp .....275 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:520px" %) 276 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:40px" %)**8**|(% style="width:20px" %)**2**|(% style="width:25px" %)**2**|(% style="width:60px" %)**1**|(% style="width:20px" %)**1**|(% style="width:40px" %)**1**|(% style="width:40px" %)**2**|(% style="width:50px" %)**2**|(% style="width:50px" %)**4**|(% style="width:50px" %)**2**|(% style="width:35px" %)**2**|(% style="width:40px" %)**4** 277 +|(% style="width:96px" %)**Value**|(% style="width:83px" %)Device ID|(% style="width:44px" %)Ver|(% style="width:42px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:57px" %)MOD|(% style="width:80px" %)Interrupt|(% style="width:69px" %)Soil PH|(% style="width:134px" %)Soil Temperature|(% style="width:98px" %)Time stamp|(% style="width:134px" %)Soil Temperature|(% style="width:68px" %)Soil PH|(% style="width:125px" %)Time stamp ..... 286 286 287 287 If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NSPH01 uplink data. 288 288 ... ... @@ -329,8 +329,6 @@ 329 329 330 330 * (% style="color:#037691" %)**8 sets of recorded data:**(%%) Temperature,Soil PH,Time stamp : 010e022663154d77,....... 331 331 332 - 333 - 334 334 == 2.4 Payload Explanation and Sensor Interface == 335 335 336 336 === 2.4.1 Device ID === ... ... @@ -483,8 +483,6 @@ 483 483 * After NSPH01 join NB-IoT network. The LED will be ON for 3 seconds. 484 484 * For each uplink probe, LED will be on for 500ms. 485 485 486 - 487 - 488 488 == 2.7 Installation and Maintain == 489 489 490 490 === 2.7.1 Before measurement === ... ... @@ -527,8 +527,6 @@ 527 527 1. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 528 528 1. The probe is IP68 can be put in water. 529 529 530 - 531 - 532 532 == 2.8 PH and Temperature alarm function == 533 533 534 534 ... ... @@ -747,6 +747,12 @@ 747 747 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string. 748 748 749 749 736 +== 6.3 Not able to connect to NB-IoT network and keep showing "Signal Strength:99". == 737 + 738 + 739 +This means sensor is trying to join the NB-IoT network but fail. Please see this link for **//[[trouble shooting for signal strenght:99>>doc:Main.CSQ\:99,99.WebHome]]//**. 740 + 741 + 750 750 = 7. Order Info = 751 751 752 752 ... ... @@ -768,8 +768,6 @@ 768 768 * Package Size / pcs : cm 769 769 * Weight / pcs : g 770 770 771 - 772 - 773 773 = 9. Support = 774 774 775 775