Changes for page NSPH01-NB-IoT Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/03/30 17:53
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -48,6 +48,7 @@ 48 48 * Micro SIM card slot 49 49 * 8500mAh Battery for long term use 50 50 51 + 51 51 == 1.3 Specification == 52 52 53 53 ... ... @@ -65,6 +65,7 @@ 65 65 * - B20 @H-FDD: 800MHz 66 66 * - B28 @H-FDD: 700MHz 67 67 69 + 68 68 == 1.4 Probe Specification == 69 69 70 70 ... ... @@ -85,11 +85,13 @@ 85 85 * IP68 Protection 86 86 * Length: 3.5 meters 87 87 90 + 88 88 == 1.5 Applications == 89 89 90 90 91 91 * Smart Agriculture 92 92 96 + 93 93 == 1.6 Pin mapping and power on == 94 94 95 95 ... ... @@ -272,9 +272,9 @@ 272 272 273 273 Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded. 274 274 275 -(% border=" 2" style="background-color:#ffffcc; color:green; width:1160px" %)276 -|(% style="width: 96px" %)**Size(bytes)**|(% style="width:83px" %)**8**|(% style="width:44px" %)**2**|(% style="width:42px" %)**2**|(% style="width:124px" %)1|(% style="width:57px" %)1|(% style="width:80px" %)1|(% style="width:69px" %)2|(% style="width:134px" %)2|(% style="width:98px" %)4|(% style="width:134px" %)2|(% style="width:68px" %)2|(% style="width:125px" %)4277 -|(% style="width:96px" %)**Value**|(% style="width:83px" %)Device ID|(% style="width:44px" %)Ver|(% style="width:42px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:57px" %)MOD|(% style="width:80px" %)Interrupt|(% style="width:69px" %)Soil PH|(% style="width:134px" %)Soil Temperature|(% style="width:98px" %)Time stamp|(% style="width:134px" %)Soil Temperature|(% style="width:68px" %)Soil PH|(% style="width:125px" %)Time stamp ..... 279 +(% border="1.5" style="background-color:#ffffcc; color:green; width:520px" %) 280 +|=(% scope="row" style="width: 50px;" %)**Size(bytes)**|(% style="width:40px" %)**8**|(% style="width:20px" %)**2**|(% style="width:20px" %)**2**|(% style="width:60px" %)**1**|(% style="width:20px" %)**1**|(% style="width:40px" %)**1**|(% style="width:40px" %)**2**|(% style="width:60px" %)**2**|(% style="width:50px" %)**4**|(% style="width:60px" %)**2**|(% style="width:40px" %)**2**|(% style="width:40px" %)**4** 281 +|=(% style="width: 96px;" %)**Value**|(% style="width:83px" %)Device ID|(% style="width:44px" %)Ver|(% style="width:42px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:57px" %)MOD|(% style="width:80px" %)Interrupt|(% style="width:69px" %)Soil PH|(% style="width:134px" %)Soil Temperature|(% style="width:98px" %)Time stamp|(% style="width:134px" %)Soil Temperature|(% style="width:68px" %)Soil PH|(% style="width:125px" %)Time stamp ..... 278 278 279 279 If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NSPH01 uplink data. 280 280 ... ... @@ -296,22 +296,32 @@ 296 296 ((( 297 297 298 298 299 -where: 303 +**where:** 300 300 ))) 301 301 302 -* Device ID: 0xf868411056754138 = f868411056754138 303 -* Version: 0x0064=100=1.0.0 304 -* BAT: 0x0c78 = 3192 mV = 3.192V 305 -* Singal: 0x17 = 23 306 -* Mod: 0x01 = 1 307 -* Interrupt: 0x00= 0 308 -* Soil PH: 0x0225= 549 = 5.49 309 -* Soil Temperature: 0x010b =267=26.7 °C 310 -* Time stamp : 0x6315537b =1662342011 ([[Unix Epoch Time>>url:http://www.epochconverter.com/]]) 311 -* Soil Temperature,Soil PH,Time stamp : 010b0226631550fb 312 -* 8 sets of recorded data: Temperature,Soil PH,Time stamp : 010e022663154d77,....... 306 +* (% style="color:#037691" %)**Device ID:**(%%)** **0xf868411056754138 = f868411056754138 313 313 308 +* (% style="color:#037691" %)**Version:** (%%) 0x0064=100=1.0.0 314 314 310 +* (% style="color:#037691" %)**BAT:** (%%) 0x0c78 = 3192 mV = 3.192V 311 + 312 +* (% style="color:#037691" %)**Singal:** (%%)0x17 = 23 313 + 314 +* (% style="color:#037691" %)**Mod:** (%%) 0x01 = 1 315 + 316 +* (% style="color:#037691" %)**Interrupt:**(%%) 0x00= 0 317 + 318 +* (% style="color:#037691" %)**Soil PH:** (%%) 0x0225= 549 = 5.49 319 + 320 +* (% style="color:#037691" %)**Soil Temperature:**(%%) 0x010b =267=26.7 °C 321 + 322 +* (% style="color:#037691" %)**Time stamp :** (%%) 0x6315537b =1662342011 ([[Unix Epoch Time>>url:http://www.epochconverter.com/]]) 323 + 324 +* (% style="color:#037691" %)**Soil Temperature,Soil PH,Time stamp : **(%%) 010b0226631550fb 325 + 326 +* (% style="color:#037691" %)**8 sets of recorded data:**(%%) Temperature,Soil PH,Time stamp : 010e022663154d77,....... 327 + 328 + 315 315 == 2.4 Payload Explanation and Sensor Interface == 316 316 317 317 ... ... @@ -475,7 +475,6 @@ 475 475 * After NSPH01 join NB-IoT network. The LED will be ON for 3 seconds. 476 476 * For each uplink probe, LED will be on for 500ms. 477 477 478 - 479 479 == 2.7 Installation and Maintain == 480 480 481 481 ... ... @@ -521,7 +521,6 @@ 521 521 1. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 522 522 1. The probe is IP68 can be put in water. 523 523 524 - 525 525 == 2.8 PH and Temperature alarm function == 526 526 527 527 ... ... @@ -565,7 +565,7 @@ 565 565 566 566 The diagram below explains the relationship between TR, NOUD, and TDC more clearly**:** 567 567 568 -[[image:image-20221009000 513-1.png||height="732" width="1018"]]580 +[[image:image-20221009000933-1.png||height="750" width="1043"]] 569 569 570 570 571 571