From version < 51.3 >
edited by Xiaoling
on 2022/09/12 15:01
To version < 51.5 >
edited by Xiaoling
on 2022/09/12 15:22
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -202,11 +202,12 @@
202 202  
203 203  
204 204  This feature is supported since firmware version v1.0.1
205 -(%%)
206 -* **(% style="color:blue" %)AT+PRO=2   ** ~/~/  Set to use UDP protocol to uplink
207 -* **(% style="color:blue" %)AT+SERVADDR=120.24.4.116,5601   ** (%%) ~/~/  to set UDP server address and port
208 -* **(% style="color:blue" %)AT+CFM=1       ** (%%) ~/~/  If the server does not respond, this command is unnecessar
209 209  
206 +* (% style="color:blue" %)**AT+PRO=2   ** (%%) ~/~/  Set to use UDP protocol to uplink
207 +* (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5601   ** (%%) ~/~/  to set UDP server address and port
208 +* (% style="color:blue" %)**AT+CFM=1       ** (%%) ~/~/  If the server does not respond, this command is unnecessar
209 +
210 +
210 210  [[image:image-20220907153643-9.png||height="401" width="734"]]
211 211  
212 212  
... ... @@ -213,17 +213,19 @@
213 213  [[image:image-20220907153703-10.png||height="309" width="738"]]
214 214  
215 215  
217 +
216 216  === 2.2.6 Use MQTT protocol to uplink data ===
217 217  
220 +
218 218  This feature is supported since firmware version v110
219 219  
220 -* **(% style="color:blue" %)AT+PRO=3   ** (%%) ~/~/Set to use MQTT protocol to uplink
221 -* **(% style="color:blue" %)AT+SERVADDR=120.24.4.116,1883   ** (%%) ~/~/Set MQTT server address and port
222 -* **(% style="color:blue" %)AT+CLIENT=CLIENT       ** (%%) ~/~/Set up the CLIENT of MQTT
223 -* **(% style="color:blue" %)AT+UNAME=UNAME                               ** (%%)~/~/Set the username of MQTT
224 -* **(% style="color:blue" %)AT+PWD=PWD                                        ** (%%)~/~/Set the password of MQTT
225 -* **(% style="color:blue" %)AT+PUBTOPIC=NSE01_PUB                    **(%%) ~/~/Set the sending topic of MQTT
226 -* **(% style="color:blue" %)AT+SUBTOPIC=NSE01_SUB          ** (%%) ~/~/Set the subscription topic of MQTT
223 +* (% style="color:blue" %)**AT+PRO=3   ** (%%) ~/~/ Set to use MQTT protocol to uplink
224 +* (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,1883   ** (%%) ~/~/ Set MQTT server address and port
225 +* (% style="color:blue" %)**AT+CLIENT=CLIENT       ** (%%) ~/~/ Set up the CLIENT of MQTT
226 +* (% style="color:blue" %)**AT+UNAME=UNAME                               **(%%)~/~/ Set the username of MQTT
227 +* (% style="color:blue" %)**AT+PWD=PWD                                        **(%%)~/~/ Set the password of MQTT
228 +* (% style="color:blue" %)**AT+PUBTOPIC=NSE01_PUB                    **(%%)~/~/ Set the sending topic of MQTT
229 +* (% style="color:blue" %)**AT+SUBTOPIC=NSE01_SUB          ** (%%) ~/~/ Set the subscription topic of MQTT
227 227  
228 228  
229 229  [[image:image-20220907153739-11.png||height="491" width="764"]]
... ... @@ -231,6 +231,7 @@
231 231  
232 232  [[image:image-20220907153751-12.png||height="555" width="769"]]
233 233  
237 +
234 234  MQTT protocol has a much higher power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval.
235 235  
236 236  
... ... @@ -238,10 +238,11 @@
238 238  
239 239  === 2.2.7 Use TCP protocol to uplink data ===
240 240  
245 +
241 241  This feature is supported since firmware version v110
242 242  
243 -* **(% style="color:blue" %)AT+PRO=4   ** (%%) ~/~/ Set to use TCP protocol to uplink
244 -* **(% style="color:blue" %)AT+SERVADDR=120.24.4.116,5600   ** (%%) ~/~/ to set TCP server address and port
248 +* (% style="color:blue" %)**AT+PRO=4   ** (%%) ~/~/ Set to use TCP protocol to uplink
249 +* (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5600   ** (%%) ~/~/ to set TCP server address and port
245 245  
246 246  
247 247  [[image:image-20220907153818-13.png||height="486" width="668"]]
... ... @@ -251,28 +251,31 @@
251 251  
252 252  
253 253  
254 -
255 255  === 2.2.8 Change Update Interval ===
256 256  
261 +
257 257  Users can use the below command to change the **uplink interval**.
258 258  
259 -* **(% style="color:blue" %)AT+TDC=7200      ** (%%) ~/~/ Set Update Interval to 7200s (2 hour)
264 +* (% style="color:blue" %)**AT+TDC=7200      ** (%%) ~/~/ Set Update Interval to 7200s (2 hour)
260 260  
261 -**(% style="color:red" %)NOTE: By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).**
262 262  
267 +(% style="color:red" %)**NOTE: By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).**
263 263  
269 +
270 +
264 264  == 2.3  Uplink Payload ==
265 265  
273 +
266 266  In this mode, uplink payload includes 87 bytes in total by default.
267 267  
268 268  Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded.
269 269  
270 -|**Size(bytes)**|**8**|**2**|**2**|1|1|1|2|2|4|2|2|4
271 -|**Value**|Device ID|Ver|BAT|Signal Strength|MOD|Interrupt|Soil PH|Soil Temperature|Time stamp|Soil Temperature|Soil PH|Time stamp  .....
278 +(% border="2" style="background-color:#ffffcc; color:green; width:1160px" %)
279 +|(% style="width:96px" %)**Size(bytes)**|(% style="width:83px" %)**8**|(% style="width:44px" %)**2**|(% style="width:42px" %)**2**|(% style="width:124px" %)1|(% style="width:57px" %)1|(% style="width:80px" %)1|(% style="width:69px" %)2|(% style="width:134px" %)2|(% style="width:98px" %)4|(% style="width:134px" %)2|(% style="width:68px" %)2|(% style="width:125px" %)4
280 +|(% style="width:96px" %)**Value**|(% style="width:83px" %)Device ID|(% style="width:44px" %)Ver|(% style="width:42px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:57px" %)MOD|(% style="width:80px" %)Interrupt|(% style="width:69px" %)Soil PH|(% style="width:134px" %)Soil Temperature|(% style="width:98px" %)Time stamp|(% style="width:134px" %)Soil Temperature|(% style="width:68px" %)Soil PH|(% style="width:125px" %)Time stamp  .....
272 272  
273 273  If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NSPH01 uplink data.
274 274  
275 -(% style="text-align:center" %)
276 276  [[image:image-20220907153902-15.png||height="581" width="804"]]
277 277  
278 278  
... ... @@ -287,19 +287,25 @@
287 287  * (% style="color:blue" %)Mod: 0x01 = 1
288 288  * (% style="color:green" %)Interrupt: 0x00= 0
289 289  * Soil PH: 0x0225= 549 = 5.49
290 -* Soil Temperature:0x010B =267=26.7 °C
298 +* Soil Temperature: 0x010B =267=26.7 °C
291 291  * Time stamp : 0x6315537b =1662342011  ([[Unix Epoch Time>>url:http://www.epochconverter.com/]])
292 292  * Soil Temperature,Soil PH,Time stamp : 010b0226631550fb
293 293  * (% style="color:red" %)8 sets of recorded data: Temperature,Soil PH,Time stamp : 010e022663154d77,.......
294 294  
303 +
304 +
305 +
295 295  == 2.4  Payload Explanation and Sensor Interface ==
296 296  
308 +
297 297  === 2.4.1  Device ID ===
298 298  
311 +
299 299  By default, the Device ID equal to the last 15 bits of IMEI.
300 300  
301 -User can use **(% style="color:blue" %)AT+DEUI** (%%)to set Device ID
314 +User can use (% style="color:blue" %)**AT+DEUI** (%%)to set Device ID
302 302  
316 +
303 303  **Example:**
304 304  
305 305  AT+DEUI=868411056754138
... ... @@ -306,14 +306,20 @@
306 306  
307 307  The Device ID is stored in a none-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID.
308 308  
323 +
324 +
309 309  === 2.4.2  Version Info ===
310 310  
327 +
311 311  Specify the software version: 0x64=100, means firmware version 1.00.
312 312  
313 313  For example: 0x00 64 : this device is NSPH01 with firmware version 1.0.0.
314 314  
332 +
333 +
315 315  === 2.4.3  Battery Info ===
316 316  
336 +
317 317  Check the battery voltage for NSPH01.
318 318  
319 319  Ex1: 0x0B45 = 2885mV
... ... @@ -320,8 +320,11 @@
320 320  
321 321  Ex2: 0x0B49 = 2889mV
322 322  
343 +
344 +
323 323  === 2.4.4  Signal Strength ===
324 324  
347 +
325 325  NB-IoT Network signal Strength.
326 326  
327 327  **Ex1: 0x1d = 29**
... ... @@ -336,8 +336,11 @@
336 336  
337 337  **99**    Not known or not detectable
338 338  
362 +
363 +
339 339  === 2.4.5  Soil PH ===
340 340  
366 +
341 341  Get the PH content of the soil. The value range of the register is 300-1000(Decimal), divide this value by 100 to get the percentage of PH in the soil.
342 342  
343 343  For example, if the data you get from the register is **__0x05 0xDC__**, the PH content in the soil is
... ... @@ -344,8 +344,11 @@
344 344  
345 345  **0229(H) = 549(D) /100 = 5.49.**
346 346  
373 +
374 +
347 347  === 2.4.6  Soil Temperature ===
348 348  
377 +
349 349  Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is **__0x09 0xEC__**, the temperature content in the soil is
350 350  
351 351  **Example**:
... ... @@ -354,19 +354,25 @@
354 354  
355 355  If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/10 = -12.9 °C
356 356  
386 +
387 +
357 357  === 2.4.7  Timestamp ===
358 358  
390 +
359 359  Time stamp : 0x6315537b =1662342011
360 360  
361 361  Convert Unix timestamp to time 2022-9-5 9:40:11.
362 362  
395 +
396 +
363 363  === 2.4.8  Digital Interrupt ===
364 364  
365 -Digital Interrupt refers to pin **GPIO_EXTI**, and there are different trigger methods. When there is a trigger, the NSPH01 will send a packet to the server.
366 366  
400 +Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NSPH01 will send a packet to the server.
401 +
367 367  The command is:
368 368  
369 -**AT+INTMOD=3 ** ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.**
404 +(% style="color:blue" %)**AT+INTMOD=3 ** (%%) ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.**
370 370  
371 371  The lower four bits of this data field shows if this packet is generated by interrupt or not. Click here for the hardware and software set up.
372 372  
... ... @@ -376,34 +376,33 @@
376 376  
377 377  0x(01): Interrupt Uplink Packet.
378 378  
414 +
415 +
379 379  === 2.4.9  ​+5V Output ===
380 380  
418 +
381 381  NSPH01 will enable +5V output before all sampling and disable the +5v after all sampling. 
382 382  
383 383  The 5V output time can be controlled by AT Command.
384 384  
385 -**AT+5VT=1000**
423 +(% style="color:blue" %)**AT+5VT=1000**
386 386  
387 387  Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.** **
388 388  
389 389  
428 +
390 390  == 2.5  Downlink Payload ==
391 391  
431 +
392 392  By default, NSPH01 prints the downlink payload to console port.
393 393  
394 -(% style="text-align:center" %)
395 395  [[image:image-20220907154636-17.png]]
396 396  
397 397  
437 +(% style="color:blue" %)**Examples:**
398 398  
439 +* (% style="color:#037691" %)** Set TDC**
399 399  
400 -
401 -
402 -
403 -**Examples:**
404 -
405 -* **Set TDC**
406 -
407 407  If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
408 408  
409 409  Payload:    01 00 00 1E    TDC=30S
... ... @@ -410,16 +410,19 @@
410 410  
411 411  Payload:    01 00 00 3C    TDC=60S
412 412  
413 -* **Reset**
447 +* (% style="color:#037691" %)** Reset**
414 414  
415 415  If payload = 0x04FF, it will reset the NSPH01
416 416  
417 -* **INTMOD**
451 +* (% style="color:#037691" %)** INTMOD**
418 418  
419 419  Downlink Payload: 06000003, Set AT+INTMOD=3
420 420  
455 +
456 +
421 421  == 2.6  ​LED Indicator ==
422 422  
459 +
423 423  The NSPH01 has an internal LED which is to show the status of different state.
424 424  
425 425  * When power on, NSPH01 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe)
... ... @@ -427,16 +427,25 @@
427 427  * After NSPH01 join NB-IoT network. The LED will be ON for 3 seconds.
428 428  * For each uplink probe, LED will be on for 500ms.
429 429  
430 -== 2.7 Installation and Maintain ==
431 431  
432 -=== 2.7.1 Before measurement ===
433 433  
469 +
470 +== 2.7  Installation and Maintain ==
471 +
472 +
473 +=== 2.7.1  Before measurement ===
474 +
475 +
434 434  If the NSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
435 435  
436 -=== 2.7.2 Measurement ===
437 437  
479 +
480 +=== 2.7.2  Measurement ===
481 +
482 +
438 438  **Measurement the soil surface:**
439 439  
485 +
440 440  [[image:image-20220907154700-18.png]] ​
441 441  
442 442  Choose the proper measuring position. Split the surface soil according to the measured deep.
... ... @@ -447,6 +447,7 @@
447 447  
448 448  Put soil over the probe after insert. And start to measure.
449 449  
496 +
450 450  **Measurement inside soil:**
451 451  
452 452  Dig a hole with diameter > 20CM.
... ... @@ -453,8 +453,11 @@
453 453  
454 454  Insert the probe inside, method like measure the surface.
455 455  
456 -=== 2.7.3 Maintain Probe ===
457 457  
504 +
505 +=== 2.7.3  Maintain Probe ===
506 +
507 +
458 458  1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
459 459  1. After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
460 460  1. Probe reference electrode is also no strong, need to avoid strong force or hitting.
... ... @@ -462,12 +462,16 @@
462 462  1. Avoid the probes to touch oily matter. Which will cause issue in accuracy.
463 463  1. The probe is IP68 can be put in water.
464 464  
465 -== 2.8 PH and Temperature alarm function ==
466 466  
467 -➢ AT Command:
468 468  
469 -AT+ PHALARM=min,max
470 470  
518 +== 2.8  PH and Temperature alarm function ==
519 +
520 +
521 +**➢ AT Command:**
522 +
523 +**AT+ PHALARM=min,max**
524 +
471 471  ² When min=3, and max≠0, Alarm higher than max
472 472  
473 473  ² When min≠0, and max=0, Alarm lower than min
... ... @@ -474,10 +474,11 @@
474 474  
475 475  ² When min≠0 and max≠0, Alarm higher than max or lower than min
476 476  
477 -Example:
478 478  
479 -AT+ PHALARM =5,8 ~/~/ Alarm when PH lower than 5.
532 +**Example:**
480 480  
534 +AT+ PHALARM =5,8  ~/~/ Alarm when PH lower than 5.
535 +
481 481  AT+ TEMPALARM=min,max
482 482  
483 483  ² When min=0, and max≠0, Alarm higher than max
... ... @@ -486,50 +486,64 @@
486 486  
487 487  ² When min≠0 and max≠0, Alarm higher than max or lower than min
488 488  
489 -Example:
490 490  
491 -AT+ TEMPALARM=20,30 ~/~/ Alarm when temperature lower than 20.
545 +**Example:**
492 492  
547 +AT+ TEMPALARM=20,30  ~/~/ Alarm when temperature lower than 20.
493 493  
549 +
550 +
494 494  == 2.9 Set the number of data to be uploaded and the recording time ==
495 495  
496 -➢ AT Command:
497 497  
498 -AT+TR=900  ~/~/The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
554 +**➢ AT Command:**
499 499  
500 -AT+NOUD=8  ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
556 +**AT+TR=900**  ~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
501 501  
558 +**AT+NOUD=8**  ~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
502 502  
560 +
503 503  == 2.10 Read or Clear cached data ==
504 504  
505 -➢ AT Command:
506 506  
507 -AT+CDP ~/~/ Read cached data
564 +**➢ AT Command:**
508 508  
566 +**AT+CDP**  ~/~/  Read cached data
567 +
568 +**AT+CDP=0** ~/~/ Clear cached data
569 +
570 +
509 509  [[image:image-20220907154700-19.png]]
510 510  
511 511  
512 -AT+CDP=0 ~/~/ Clear cached data
513 513  
575 +== 2.11  Calibration ==
514 514  
515 -== 2.11 Calibration ==
516 516  
517 517  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
518 518  
519 519  After stable, user can use below command to calibrate.
520 520  
582 +
521 521  [[image:image-20220907154700-20.png]] ​
522 522  
585 +
586 +
523 523  == 2.12  ​Firmware Change Log ==
524 524  
589 +
525 525  Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0>>url:https://www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0]]
526 526  
527 527  Upgrade Instruction: [[Upgrade Firmware>>path:#H5.1200BHowtoUpgradeFirmware]]
528 528  
594 +
595 +
529 529  == 2.13  ​Battery Analysis ==
530 530  
598 +
531 531  === 2.13.1  ​Battery Type ===
532 532  
601 +
533 533  The NSPH01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
534 534  
535 535  The battery is designed to last for several years depends on the actually use environment and update interval. 
... ... @@ -542,8 +542,11 @@
542 542  
543 543  [[image:image-20220907154700-21.png]] ​
544 544  
614 +
615 +
545 545  === 2.13.2  Power consumption Analyze ===
546 546  
618 +
547 547  Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
548 548  
549 549  Instruction to use as below:
... ... @@ -563,29 +563,40 @@
563 563  
564 564  ​
565 565  
638 +
566 566  === 2.13.3  ​Battery Note ===
567 567  
641 +
568 568  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
569 569  
644 +
645 +
570 570  === 2.13.4  Replace the battery ===
571 571  
648 +
572 572  The default battery pack of NSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
573 573  
651 +
652 +
574 574  = 3. ​ Access NB-IoT Module =
575 575  
655 +
576 576  Users can directly access the AT command set of the NB-IoT module.
577 577  
578 578  The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 
579 579  
580 -(% style="text-align:center" %)
660 +
581 581  [[image:image-20220907154700-23.png]]
582 582  
583 583  ​
584 584  
665 +
585 585  = 4.  Using the AT Commands =
586 586  
668 +
587 587  == 4.1  Access AT Commands ==
588 588  
671 +
589 589  See this link for detail:  [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
590 590  
591 591  AT+<CMD>?  : Help on <CMD>
... ... @@ -596,6 +596,7 @@
596 596  
597 597  AT+<CMD>=?  : Get the value
598 598  
682 +
599 599  **General Commands**      
600 600  
601 601  AT  : Attention       
... ... @@ -645,10 +645,12 @@
645 645  
646 646  AT+URI            : Resource parameters
647 647  
732 +
648 648  **UDP Management**
649 649  
650 650  AT+CFM          : Upload confirmation mode (only valid for UDP)
651 651  
737 +
652 652  **MQTT Management**
653 653  
654 654  AT+CLIENT               : Get or Set MQTT client
... ... @@ -661,6 +661,7 @@
661 661  
662 662  AT+SUBTOPIC  : Get or Set MQTT subscription topic
663 663  
750 +
664 664  **Information**          
665 665  
666 666  AT+FDR  : Factory Data Reset
... ... @@ -667,36 +667,56 @@
667 667  
668 668  AT+PWORD  : Serial Access Password
669 669  
757 +
758 +
670 670  = ​5.  FAQ =
671 671  
761 +
672 672  == 5.1 ​ How to Upgrade Firmware ==
673 673  
764 +
674 674  User can upgrade the firmware for 1) bug fix, 2) new feature release.
675 675  
676 676  Please see this link for how to upgrade:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]
677 677  
678 -**Notice, **NSPH01 **and **NSPH01 **share the same mother board. They use the same connection and method to update.**
769 +**Notice, **NSPH01 **and **LSPH01 **share the same mother board. They use the same connection and method to update.**
679 679  
771 +
772 +
680 680  == 5.2  Can I calibrate NSPH01 to different soil types? ==
681 681  
775 +
682 682  NSPH01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]].
683 683  
778 +
779 +
684 684  = 6.  Trouble Shooting =
685 685  
782 +
686 686  == 6.1  ​Connection problem when uploading firmware ==
687 687  
785 +
688 688  **Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]
689 689  
788 +
789 +
690 690  == 6.2  AT Command input doesn't work ==
691 691  
692 -In the case if user can see the console output but can't type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn't send **ENTER** while press the send key, user need to add ENTER in their string.
693 693  
793 +In the case if user can see the console output but can't type input to the device. Please check if you already include the **(% style="color:green" %)ENTER**(%%) while sending out the command. Some serial tool doesn't send **(% style="color:green" %)ENTER** (%%)while press the send key, user need to add ENTER in their string.
794 +
795 +
796 +
694 694  = 7. ​ Order Info =
695 695  
799 +
696 696  Part Number**:** NSPH01
697 697  
802 +
803 +
698 698  = 8.  Packing Info =
699 699  
806 +
700 700  **Package Includes**:
701 701  
702 702  * NSPH01 NB-IoT pH Sensor x 1
... ... @@ -707,8 +707,12 @@
707 707  * Size: 195 x 125 x 55 mm
708 708  * Weight:   420g
709 709  
817 +
818 +
819 +
710 710  = 9.  Support =
711 711  
822 +
712 712  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
713 713  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
714 714  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0