Changes for page NSPH01-NB-IoT Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/03/30 17:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,29 +7,32 @@ 7 7 8 8 9 9 10 -= 1. Introduction = 10 += 1. Introduction = 11 11 12 12 13 -== 1.1 What is NSPH01 Soil pH Sensor == 13 +== 1.1 What is NSPH01 Soil pH Sensor == 14 14 15 15 16 -The Dragino NSPH01 is a **(% style="color:blue" %)NB-IoT soil pH sensor**(%%) for IoT of Agriculture. It is designed to measure the soil pH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.16 +The Dragino NSPH01 is a (% style="color:blue" %)**NB-IoT soil pH sensor**(%%) for IoT of Agriculture. It is designed to measure the soil pH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 17 17 18 -NSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:blue" %)pH **(%%)with high accuracy and stable value. The NSPH01 probe can be buried into soil for long time use.18 +NSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:blue" %)pH (%%)**with high accuracy and stable value. The NSPH01 probe can be buried into soil for long time use. 19 19 20 20 NarrowBand-Internet of Things (NB-IoT) is a standards-based low power wide area (LPWA) technology developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity and spectrum efficiency, especially in deep coverage. 21 -\\NSPH01 supports different uplink methods include **(% style="color:blue" %)TCP,MQTT,UDP and CoAP **(%%)for different application requirement.22 -\\NSPH01 is powered by **(% style="color:blue" %)8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method)23 -\\To use NSPH01, user needs to check if there is NB-IoT coverage in the installation area and with the bands NSPH01 supports. If the local operator supports it, user needs to get a **(% style="color:blue" %)NB-IoT SIM card**21 +\\NSPH01 supports different uplink methods include (% style="color:blue" %)**TCP,MQTT,UDP and CoAP **(%%)for different application requirement. 22 +\\NSPH01 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method) 23 +\\To use NSPH01, user needs to check if there is NB-IoT coverage in the installation area and with the bands NSPH01 supports. If the local operator supports it, user needs to get a (% style="color:blue" %)**NB-IoT SIM card** (%%)from local operator and install NSPH01 to get NB-IoT network connection. 24 24 25 - (% style="text-align:center" %)25 + 26 26 [[image:image-20220907153151-1.png]] 27 27 28 - (% style="text-align:center" %)28 + 29 29 [[image:M_K`YF9`CAYAE\@}3T]FHT$9.png]] 30 30 31 -== 1.2 Features == 32 32 32 + 33 +== 1.2 Features == 34 + 35 + 33 33 * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD 34 34 * Monitor soil pH with temperature compensation. 35 35 * Monitor soil temperature ... ... @@ -45,14 +45,17 @@ 45 45 * Micro SIM card slot 46 46 * 8500mAh Battery for long term use 47 47 51 + 52 + 48 48 == 1.3 Specification == 49 49 50 -**Common DC Characteristics:** 51 51 56 +(% style="color:#037691" %)**Common DC Characteristics:** 57 + 52 52 * Supply Voltage: 2.1v ~~ 3.6v 53 53 * Operating Temperature: -40 ~~ 85°C 54 54 55 -**NB-IoT Spec:** 61 +(% style="color:#037691" %)**NB-IoT Spec:** 56 56 57 57 * - B1 @H-FDD: 2100MHz 58 58 * - B3 @H-FDD: 1800MHz ... ... @@ -61,10 +61,13 @@ 61 61 * - B20 @H-FDD: 800MHz 62 62 * - B28 @H-FDD: 700MHz 63 63 64 -== 1.4 Probe Specification == 65 65 66 -**Soil pH:** 67 67 72 +== 1.4 Probe Specification == 73 + 74 + 75 +(% style="color:#037691" %)**Soil pH:** 76 + 68 68 * Range: 3 ~~ 10 pH 69 69 * Resolution: 0.01 pH 70 70 * Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen) ... ... @@ -72,7 +72,7 @@ 72 72 * IP68 Protection 73 73 * Length: 3.5 meters 74 74 75 -**Soil Temperature:** 84 +(% style="color:#037691" %)**Soil Temperature:** 76 76 77 77 * Range -40℃~85℃ 78 78 * Resolution: 0.1℃ ... ... @@ -80,31 +80,43 @@ 80 80 * IP68 Protection 81 81 * Length: 3.5 meters 82 82 83 -== 1.5 Applications == 84 84 93 + 94 +== 1.5 Applications == 95 + 96 + 85 85 * Smart Agriculture 86 86 87 -== 1.6 Pin mapping and power on == 88 88 89 -(% style="text-align:center" %) 100 + 101 +== 1.6 Pin mapping and power on == 102 + 103 + 90 90 [[image:image-20220907153300-2.png]] 91 91 92 92 107 + 93 93 = 2. Use NSPH01 to communicate with IoT Server = 94 94 110 + 95 95 == 2.1 How it works == 96 96 113 + 97 97 The NSPH01 is equipped with a NB-IoT module, the pre-loaded firmware in NSPH01 will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined by NSPH01. 98 98 99 99 The diagram below shows the working flow in default firmware of NSPH01: 100 100 101 - (% style="text-align:center" %)118 + 102 102 [[image:image-20220907153416-3.png]] 103 103 121 + 122 + 104 104 == 2.2 Configure the NSPH01 == 105 105 125 + 106 106 === 2.2.1 Test Requirement === 107 107 128 + 108 108 To use NSPH01 in the field, make sure meet below requirements: 109 109 110 110 * Your local operator has already distributed a NB-IoT Network there. ... ... @@ -111,163 +111,216 @@ 111 111 * The local NB-IoT network used the band that NSPH01 supports. 112 112 * Your operator is able to distribute the data received in their NB-IoT network to your IoT server. 113 113 114 -Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. The NSPH01 will use 135 +Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. The NSPH01 will use** CoAP(120.24.4.116:5683) **or raw **UDP(120.24.4.116:5601)** or **MQTT(120.24.4.116:1883)**or **TCP(120.24.4.116:5600)**protocol to send data to the test server. 115 115 116 - (% style="text-align:center" %)137 + 117 117 [[image:image-20220907153445-4.png]] 118 118 119 119 141 + 120 120 === 2.2.2 Insert SIM card === 121 121 144 + 122 122 User need to take out the NB-IoT module and insert the SIM card like below. ((% style="color:red" %) Pay attention to the direction(%%)) 123 123 124 - (% style="text-align:center" %)147 + 125 125 [[image:image-20220907153505-5.png]] 126 126 150 + 151 + 127 127 === 2.2.3 Connect USB – TTL to NSPH01 to configure it === 128 128 129 -User need to configure NSPH01 via serial port to set the **Server Address** / **Uplink Topic** to define where and how-to uplink packets. NSPH01 support AT Commands, user can use a USB to TTL adapter to connect to NSPH01 and use AT Commands to configure it, as below. 130 130 131 -**Connect ion:**155 +User need to configure NSPH01 via serial port to set the (% style="color:blue" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NSPH01 support AT Commands, user can use a USB to TTL adapter to connect to NSPH01 and use AT Commands to configure it, as below. 132 132 133 - USB TTL GND <~-~-~-~-> GND 134 134 135 - USBTTL TXD <~-~-~-~-> UART_RXD158 +(% style="color:blue" %)**Connection:** 136 136 137 - USB TTL RXD <~-~-~-~->UART_TXD160 +**~ (% style="background-color:yellow" %) USB TTL GND <~-~-~-~-> GND(%%)** 138 138 162 +**~ (% style="background-color:yellow" %) USB TTL TXD <~-~-~-~-> UART_RXD(%%)** 163 + 164 +**~ (% style="background-color:yellow" %) USB TTL RXD <~-~-~-~-> UART_TXD(%%)** 165 + 166 + 139 139 In the PC, use below serial tool settings: 140 140 141 -* Baud: **9600** 142 -* Data bits:** 8** 143 -* Stop bits: **1** 144 -* Parity: **None** 145 -* Flow Control: **None** 169 +* Baud: (% style="color:green" %)**9600** 170 +* Data bits:** (% style="color:green" %)8(%%)** 171 +* Stop bits: (% style="color:green" %)**1** 172 +* Parity: (% style="color:green" %)**None** 173 +* Flow Control: (% style="color:green" %)**None** 146 146 147 -Make sure the switch is in FLASH position, then power on device by connecting the jumper on NSPH01. NSPH01 will output system info once power on as below, we can enter the **password: 12345678** to access AT Command input. 175 +Make sure the switch is in FLASH position, then power on device by connecting the jumper on NSPH01. NSPH01 will output system info once power on as below, we can enter the (% style="color:green" %)**password: 12345678**(%%) to access AT Command input. 148 148 149 -(% style="text-align:center" %) 150 -[[image:image-20220907153529-6.png]] 151 151 152 - **Note: the valid AT Commands can befound at:**[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]178 +[[image:image-20220912144017-1.png]] 153 153 180 + 181 +(% style="color:red" %)**Note: the valid AT Commands can be found at:**(%%)** **[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 182 + 183 + 184 + 154 154 === 2.2.4 Use CoAP protocol to uplink data === 155 155 156 -**Note: if you don't have CoAP server, you can refer this link to set up one: **[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]] 157 157 158 -** Usebelowcommands:**188 +(% style="color:red" %)**Note: if you don't have CoAP server, you can refer this link to set up one:**(%%)** **[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]] 159 159 160 -* **AT+PRO=1** ~/~/ Set to use CoAP protocol to uplink 161 -* **AT+SERVADDR=120.24.4.116,5683 ** ~/~/ to set CoAP server address and port 162 -* **AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** ~/~/Set COAP resource path 163 163 191 +(% style="color:blue" %)**Use below commands:** 192 + 193 +* (% style="color:#037691" %)**AT+PRO=1** (%%) ~/~/ Set to use CoAP protocol to uplink 194 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5683 ** (%%) ~/~/ to set CoAP server address and port 195 +* (% style="color:#037691" %)**AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** (%%) ~/~/ Set COAP resource path 196 + 164 164 For parameter description, please refer to AT command set 165 165 166 - (% style="text-align:center" %)199 + 167 167 [[image:image-20220907153551-7.png||height="502" width="740"]] 168 168 169 -After configure the server address and **reset the device** (via AT+ATZ ), NSPH01 will start to uplink sensor values to CoAP server. 170 170 171 -(% style="text-align:center" %) 203 +After configure the server address and (% style="color:green" %)**reset the device (via AT+ATZ )**(%%), NSPH01 will start to uplink sensor values to CoAP server. 204 + 205 + 172 172 [[image:image-20220907153612-8.png||height="529" width="729"]] 173 173 174 174 209 + 175 175 === 2.2.5 Use UDP protocol to uplink data(Default protocol) === 176 176 212 + 177 177 This feature is supported since firmware version v1.0.1 178 178 179 -* **AT+PRO=2 ** ~/~/ Set to use UDP protocol to uplink 180 -* **AT+SERVADDR=120.24.4.116,5601 ** ~/~/ to set UDP server address and port 181 -* **AT+CFM=1 ** ~/~/If the server does not respond, this command is unnecessar 215 +* (% style="color:blue" %)**AT+PRO=2 ** (%%) ~/~/ Set to use UDP protocol to uplink 216 +* (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5601 ** (%%) ~/~/ to set UDP server address and port 217 +* (% style="color:blue" %)**AT+CFM=1 ** (%%) ~/~/ If the server does not respond, this command is unnecessar 182 182 183 -(% style="text-align:center" %) 184 184 [[image:image-20220907153643-9.png||height="401" width="734"]] 185 185 186 - (% style="text-align:center" %)221 + 187 187 [[image:image-20220907153703-10.png||height="309" width="738"]] 188 188 189 189 225 + 190 190 === 2.2.6 Use MQTT protocol to uplink data === 191 191 228 + 192 192 This feature is supported since firmware version v110 193 193 194 -* **AT+PRO=3 ** ~/~/Set to use MQTT protocol to uplink 195 -* **AT+SERVADDR=120.24.4.116,1883 ** ~/~/Set MQTT server address and port 196 -* **AT+CLIENT=CLIENT ** ~/~/Set up the CLIENT of MQTT 197 -* **AT+UNAME=UNAME **~/~/Set the username of MQTT 198 -* **AT+PWD=PWD **~/~/Set the password of MQTT 199 -* **AT+PUBTOPIC=NSE01_PUB **~/~/Set the sending topic of MQTT 200 -* **AT+SUBTOPIC=NSE01_SUB ** ~/~/Set the subscription topic of MQTT 231 +* (% style="color:blue" %)**AT+PRO=3 ** (%%) ~/~/ Set to use MQTT protocol to uplink 232 +* (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,1883 ** (%%) ~/~/ Set MQTT server address and port 233 +* (% style="color:blue" %)**AT+CLIENT=CLIENT ** (%%) ~/~/ Set up the CLIENT of MQTT 234 +* (% style="color:blue" %)**AT+UNAME=UNAME **(%%)~/~/ Set the username of MQTT 235 +* (% style="color:blue" %)**AT+PWD=PWD **(%%)~/~/ Set the password of MQTT 236 +* (% style="color:blue" %)**AT+PUBTOPIC=NSE01_PUB **(%%)~/~/ Set the sending topic of MQTT 237 +* (% style="color:blue" %)**AT+SUBTOPIC=NSE01_SUB ** (%%) ~/~/ Set the subscription topic of MQTT 201 201 202 -(% style="text-align:center" %) 203 203 [[image:image-20220907153739-11.png||height="491" width="764"]] 204 204 205 - (% style="text-align:center" %)241 + 206 206 [[image:image-20220907153751-12.png||height="555" width="769"]] 207 207 244 + 208 208 MQTT protocol has a much higher power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval. 209 209 247 + 248 + 249 + 210 210 === 2.2.7 Use TCP protocol to uplink data === 211 211 252 + 212 212 This feature is supported since firmware version v110 213 213 214 -* **AT+PRO=4 ** ~/~/ Set to use TCP protocol to uplink 215 -* **AT+SERVADDR=120.24.4.116,5600 ** ~/~/ to set TCP server address and port 255 +* (% style="color:blue" %)**AT+PRO=4 ** (%%) ~/~/ Set to use TCP protocol to uplink 256 +* (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5600 ** (%%) ~/~/ to set TCP server address and port 216 216 217 -(% style="text-align:center" %) 218 218 [[image:image-20220907153818-13.png||height="486" width="668"]] 219 219 220 - (% style="text-align:center" %)260 + 221 221 [[image:image-20220907153827-14.png||height="236" width="684"]] 222 222 263 + 264 + 223 223 === 2.2.8 Change Update Interval === 224 224 267 + 225 225 Users can use the below command to change the **uplink interval**. 226 226 227 -* **AT+TDC=7200 ** ~/~/ Set Update Interval to 7200s (2 hour) 270 +* (% style="color:blue" %)**AT+TDC=7200 ** (%%) ~/~/ Set Update Interval to 7200s (2 hour) 228 228 229 -**NOTE: By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).** 272 +(% style="color:red" %)**NOTE: By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).** 230 230 231 231 275 + 232 232 == 2.3 Uplink Payload == 233 233 278 + 234 234 In this mode, uplink payload includes 87 bytes in total by default. 235 235 236 236 Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded. 237 237 238 -|**Size(bytes)**|**8**|**2**|**2**|1|1|1|2|2|4|2|2|4 239 -|**Value**|Device ID|Ver|BAT|Signal Strength|MOD|Interrupt|Soil PH|Soil Temperature|Time stamp|Soil Temperature|Soil PH|Time stamp ..... 283 +(% border="2" style="background-color:#ffffcc; color:green; width:1160px" %) 284 +|(% style="width:96px" %)**Size(bytes)**|(% style="width:83px" %)**8**|(% style="width:44px" %)**2**|(% style="width:42px" %)**2**|(% style="width:124px" %)1|(% style="width:57px" %)1|(% style="width:80px" %)1|(% style="width:69px" %)2|(% style="width:134px" %)2|(% style="width:98px" %)4|(% style="width:134px" %)2|(% style="width:68px" %)2|(% style="width:125px" %)4 285 +|(% style="width:96px" %)**Value**|(% style="width:83px" %)Device ID|(% style="width:44px" %)Ver|(% style="width:42px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:57px" %)MOD|(% style="width:80px" %)Interrupt|(% style="width:69px" %)Soil PH|(% style="width:134px" %)Soil Temperature|(% style="width:98px" %)Time stamp|(% style="width:134px" %)Soil Temperature|(% style="width:68px" %)Soil PH|(% style="width:125px" %)Time stamp ..... 240 240 241 241 If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NSPH01 uplink data. 242 242 243 -(% style="text-align:center" %) 244 244 [[image:image-20220907153902-15.png||height="581" width="804"]] 245 245 246 246 292 +((( 247 247 The payload is ASCII string, representative same HEX: 294 +))) 248 248 249 -0x(% style="color:red" %)f868411056754138(% style="color:blue" %)0064(% style="color:green" %)0c78(% style="color:red" %)17(% style="color:blue" %)01(% style="color:green" %)00(% style="color:red" %)**//0225010b6315537b//**010b0226631550fb//**010e022663154d77**//01110225631549f1//**011502246315466b**//01190223631542e5//**011d022163153f62**//011e022163153bde//**011e022163153859**//(%%) where: 296 +((( 297 + 298 +))) 250 250 251 -* (% style="color:red" %)Device ID: 0xf868411056754138 = f868411056754138 252 -* (% style="color:blue" %)Version: 0x0064=100=1.0.0 253 -* (% style="color:green" %)BAT: 0x0c78 = 3192 mV = 3.192V 254 -* (% style="color:red" %)Singal: 0x17 = 23 255 -* (% style="color:blue" %)Mod: 0x01 = 1 256 -* (% style="color:green" %)Interrupt: 0x00= 0 257 -* Soil PH: 0x0225= 549 = 5.49 258 -* Soil Temperature:0x010B =267=26.7 °C 259 -* Time stamp : 0x6315537b =1662342011 ([[Unix Epoch Time>>url:http://www.epochconverter.com/]]) 260 -* Soil Temperature,Soil PH,Time stamp : 010b0226631550fb 261 -* (% style="color:red" %)8 sets of recorded data: Temperature,Soil PH,Time stamp : 010e022663154d77,....... 300 +((( 301 +**0x (% style="color:red" %)__f868411056754138__ (% style="color:blue" %)__0064 __ (% style="color:green" %)__0c78__ (% style="color:#00b0f0" %)__17__ (% style="color:#7030a0" %)__01__ (% style="color:#d60093" %)__00__ (% style="color:#a14d07" %)__0225 __ (% style="color:#0020b0" %) __010b__ (% style="color:#420042" %)__6315537b__ (% style="color:#663300" %)//__010b0226631550fb__ __010e022663154d77 01110225631549f1 011502246315466b 01190223631542e5 011d022163153f62 011e022163153bde 011e022163153859__//(%%)** 302 +))) 262 262 304 +((( 305 + 306 + 307 +**where:** 308 +))) 309 + 310 +* (% style="color:#037691" %)**Device ID:**(%%)** **0xf868411056754138 = f868411056754138 311 + 312 +* (% style="color:#037691" %)**Version:** (%%) 0x0064=100=1.0.0 313 + 314 +* (% style="color:#037691" %)**BAT:** (%%) 0x0c78 = 3192 mV = 3.192V 315 + 316 +* (% style="color:#037691" %)**Singal:** (%%)0x17 = 23 317 + 318 +* (% style="color:#037691" %)**Mod:** (%%) 0x01 = 1 319 + 320 +* (% style="color:#037691" %)**Interrupt:**(%%) 0x00= 0 321 + 322 +* (% style="color:#037691" %)**Soil PH:** (%%) 0x0225= 549 = 5.49 323 + 324 +* (% style="color:#037691" %)**Soil Temperature:**(%%) 0x010b =267=26.7 °C 325 + 326 +* (% style="color:#037691" %)**Time stamp :** (%%) 0x6315537b =1662342011 ([[Unix Epoch Time>>url:http://www.epochconverter.com/]]) 327 + 328 +* (% style="color:#037691" %)**Soil Temperature,Soil PH,Time stamp : **(%%) 010b0226631550fb 329 + 330 +* (% style="color:#037691" %)**8 sets of recorded data:**(%%) Temperature,Soil PH,Time stamp : 010e022663154d77,....... 331 + 332 + 333 + 263 263 == 2.4 Payload Explanation and Sensor Interface == 264 264 336 + 265 265 === 2.4.1 Device ID === 266 266 339 + 267 267 By default, the Device ID equal to the last 15 bits of IMEI. 268 268 269 -User can use **AT+DEUI** to set Device ID 342 +User can use (% style="color:blue" %)**AT+DEUI** (%%)to set Device ID 270 270 344 + 271 271 **Example:** 272 272 273 273 AT+DEUI=868411056754138 ... ... @@ -274,14 +274,20 @@ 274 274 275 275 The Device ID is stored in a none-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID. 276 276 351 + 352 + 277 277 === 2.4.2 Version Info === 278 278 355 + 279 279 Specify the software version: 0x64=100, means firmware version 1.00. 280 280 281 281 For example: 0x00 64 : this device is NSPH01 with firmware version 1.0.0. 282 282 360 + 361 + 283 283 === 2.4.3 Battery Info === 284 284 364 + 285 285 Check the battery voltage for NSPH01. 286 286 287 287 Ex1: 0x0B45 = 2885mV ... ... @@ -288,8 +288,11 @@ 288 288 289 289 Ex2: 0x0B49 = 2889mV 290 290 371 + 372 + 291 291 === 2.4.4 Signal Strength === 292 292 375 + 293 293 NB-IoT Network signal Strength. 294 294 295 295 **Ex1: 0x1d = 29** ... ... @@ -304,18 +304,25 @@ 304 304 305 305 **99** Not known or not detectable 306 306 390 + 391 + 307 307 === 2.4.5 Soil PH === 308 308 394 + 309 309 Get the PH content of the soil. The value range of the register is 300-1000(Decimal), divide this value by 100 to get the percentage of PH in the soil. 310 310 311 -For example, if the data you get from the register is **__0x05 0xDC__**, the PH content in the soil is 397 +For example, if the data you get from the register is (% style="color:blue" %)**__0x05 0xDC__**(%%), the PH content in the soil is 312 312 313 -**0229(H) = 549(D) /100 = 5.49.** 399 +(% style="color:blue" %)**0229(H) = 549(D) /100 = 5.49.** 314 314 401 + 402 + 315 315 === 2.4.6 Soil Temperature === 316 316 317 -Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is **__0x09 0xEC__**, the temperature content in the soil is 318 318 406 +Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is (% style="color:blue" %)**__0x09 0xEC__**(%%), the temperature content in the soil is 407 + 408 + 319 319 **Example**: 320 320 321 321 If payload is 0105H: ((0x0105 & 0x8000)>>15 === 0),temp = 0105(H)/10 = 26.1 °C ... ... @@ -322,56 +322,62 @@ 322 322 323 323 If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/10 = -12.9 °C 324 324 415 + 416 + 325 325 === 2.4.7 Timestamp === 326 326 419 + 327 327 Time stamp : 0x6315537b =1662342011 328 328 329 329 Convert Unix timestamp to time 2022-9-5 9:40:11. 330 330 424 + 425 + 331 331 === 2.4.8 Digital Interrupt === 332 332 333 -Digital Interrupt refers to pin **GPIO_EXTI**, and there are different trigger methods. When there is a trigger, the NSPH01 will send a packet to the server. 334 334 429 +Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NSPH01 will send a packet to the server. 430 + 335 335 The command is: 336 336 337 -**AT+INTMOD=3 ** ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.** 433 +(% style="color:blue" %)**AT+INTMOD=3 ** (%%) ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.** 338 338 339 339 The lower four bits of this data field shows if this packet is generated by interrupt or not. Click here for the hardware and software set up. 340 340 341 -Example: 342 342 438 +**Example:** 439 + 343 343 0x(00): Normal uplink packet. 344 344 345 345 0x(01): Interrupt Uplink Packet. 346 346 444 + 445 + 347 347 === 2.4.9 +5V Output === 348 348 448 + 349 349 NSPH01 will enable +5V output before all sampling and disable the +5v after all sampling. 350 350 351 351 The 5V output time can be controlled by AT Command. 352 352 353 -**AT+5VT=1000** 453 +(% style="color:blue" %)**AT+5VT=1000** 354 354 355 355 Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.** ** 356 356 357 357 458 + 358 358 == 2.5 Downlink Payload == 359 359 461 + 360 360 By default, NSPH01 prints the downlink payload to console port. 361 361 362 -(% style="text-align:center" %) 363 363 [[image:image-20220907154636-17.png]] 364 364 365 365 467 +(% style="color:blue" %)**Examples:** 366 366 469 +* (% style="color:#037691" %)** Set TDC** 367 367 368 - 369 - 370 - 371 -**Examples:** 372 - 373 -* **Set TDC** 374 - 375 375 If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 376 376 377 377 Payload: 01 00 00 1E TDC=30S ... ... @@ -378,16 +378,19 @@ 378 378 379 379 Payload: 01 00 00 3C TDC=60S 380 380 381 -* **Reset** 477 +* (% style="color:#037691" %)** Reset** 382 382 383 383 If payload = 0x04FF, it will reset the NSPH01 384 384 385 -* **INTMOD** 481 +* (% style="color:#037691" %)** INTMOD** 386 386 387 387 Downlink Payload: 06000003, Set AT+INTMOD=3 388 388 485 + 486 + 389 389 == 2.6 LED Indicator == 390 390 489 + 391 391 The NSPH01 has an internal LED which is to show the status of different state. 392 392 393 393 * When power on, NSPH01 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe) ... ... @@ -395,16 +395,22 @@ 395 395 * After NSPH01 join NB-IoT network. The LED will be ON for 3 seconds. 396 396 * For each uplink probe, LED will be on for 500ms. 397 397 398 -== 2.7 Installation and Maintain == 497 +== 2.7 Installation and Maintain == 399 399 400 -=== 2.7.1 Before measurement === 401 401 500 +=== 2.7.1 Before measurement === 501 + 502 + 402 402 If the NSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 403 403 404 -=== 2.7.2 Measurement === 405 405 406 -**Measurement the soil surface:** 407 407 507 +=== 2.7.2 Measurement === 508 + 509 + 510 +(% style="color:#037691" %)**Measurement the soil surface:** 511 + 512 + 408 408 [[image:image-20220907154700-18.png]] 409 409 410 410 Choose the proper measuring position. Split the surface soil according to the measured deep. ... ... @@ -415,14 +415,18 @@ 415 415 416 416 Put soil over the probe after insert. And start to measure. 417 417 418 -**Measurement inside soil:** 419 419 524 +(% style="color:#037691" %)**Measurement inside soil:** 525 + 420 420 Dig a hole with diameter > 20CM. 421 421 422 422 Insert the probe inside, method like measure the surface. 423 423 424 -=== 2.7.3 Maintain Probe === 425 425 531 + 532 +=== 2.7.3 Maintain Probe === 533 + 534 + 426 426 1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 427 427 1. After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 428 428 1. Probe reference electrode is also no strong, need to avoid strong force or hitting. ... ... @@ -430,12 +430,13 @@ 430 430 1. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 431 431 1. The probe is IP68 can be put in water. 432 432 433 -== 2.8 PH and Temperature alarm function == 542 +== 2.8 PH and Temperature alarm function == 434 434 435 -➢ AT Command: 436 436 437 -AT +PHALARM=min,max545 +(% style="color:#037691" %)**➢ AT Command:** 438 438 547 +(% style="color:blue" %)**AT+ PHALARM=min,max** 548 + 439 439 ² When min=3, and max≠0, Alarm higher than max 440 440 441 441 ² When min≠0, and max=0, Alarm lower than min ... ... @@ -442,10 +442,11 @@ 442 442 443 443 ² When min≠0 and max≠0, Alarm higher than max or lower than min 444 444 445 -Example: 446 446 447 - AT+PHALARM =5,8 ~/~/ Alarm when PHlowerthan 5.556 +(% style="color:blue" %)**Example:** 448 448 558 +AT+ PHALARM =5,8 ~/~/ Alarm when PH lower than 5. 559 + 449 449 AT+ TEMPALARM=min,max 450 450 451 451 ² When min=0, and max≠0, Alarm higher than max ... ... @@ -454,50 +454,66 @@ 454 454 455 455 ² When min≠0 and max≠0, Alarm higher than max or lower than min 456 456 457 -Example: 458 458 459 - AT+TEMPALARM=20,30 ~/~/ Alarm whentemperaturelower than 20.569 +(% style="color:blue" %)**Example:** 460 460 571 +AT+ TEMPALARM=20,30 ~/~/ Alarm when temperature lower than 20. 461 461 462 -== 2.9 Set the number of data to be uploaded and the recording time == 463 463 464 -➢ AT Command: 465 465 466 - AT+TR=900~/~/Theunitis seconds, andthedefaultistorecordataonceevery900 seconds.( The minimum can beset to 180 seconds)575 +== 2.9 Set the number of data to be uploaded and the recording time == 467 467 468 -AT+NOUD=8 ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 469 469 578 +(% style="color:#037691" %)**➢ AT Command:** 470 470 471 -== 2.10 Read or Clear cached data == 580 +* (% style="color:blue" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 581 +* (% style="color:blue" %)**AT+NOUD=8** (%%) ~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 472 472 473 - ➢ATCommand:583 + The diagram below explains the relationship between TR, NOUD, and TDC more clearly**:** 474 474 475 - AT+CDP ~/~/ Read cacheddata585 +[[image:image-20221009000933-1.png||height="750" width="1043"]] 476 476 587 + 588 + 589 +== 2.10 Read or Clear cached data == 590 + 591 + 592 +(% style="color:#037691" %)**➢ AT Command:** 593 + 594 +* (% style="color:blue" %)**AT+CDP** (%%) ~/~/ Read cached data 595 +* (% style="color:blue" %)**AT+CDP=0** (%%) ~/~/ Clear cached data 596 + 477 477 [[image:image-20220907154700-19.png]] 478 478 479 479 480 -AT+CDP=0 ~/~/ Clear cached data 481 481 601 +== 2.11 Calibration == 482 482 483 -== 2.11 Calibration == 484 484 485 485 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 486 486 487 487 After stable, user can use below command to calibrate. 488 488 608 + 489 489 [[image:image-20220907154700-20.png]] 490 490 611 + 612 + 491 491 == 2.12 Firmware Change Log == 492 492 493 -Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0>>url:https://www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0]] 494 494 495 - Upgrade Instruction: [[UpgradeFirmware>>path:#H5.1200BHowtoUpgradeFirmware]]616 +Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/1tv07fro2pvjqj8/AAD-2wbfGfluTZfh38fQqdA_a?dl=0>>https://www.dropbox.com/sh/1tv07fro2pvjqj8/AAD-2wbfGfluTZfh38fQqdA_a?dl=0]] 496 496 618 +Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]] 619 + 620 + 621 + 497 497 == 2.13 Battery Analysis == 498 498 624 + 499 499 === 2.13.1 Battery Type === 500 500 627 + 501 501 The NSPH01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 502 502 503 503 The battery is designed to last for several years depends on the actually use environment and update interval. ... ... @@ -510,15 +510,18 @@ 510 510 511 511 [[image:image-20220907154700-21.png]] 512 512 640 + 641 + 513 513 === 2.13.2 Power consumption Analyze === 514 514 644 + 515 515 Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 516 516 517 517 Instruction to use as below: 518 518 519 -**Step 1: **Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 649 +(% style="color:blue" %)**Step 1: **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 520 520 521 -**Step 2: ** Open it and choose 651 +(% style="color:blue" %)**Step 2: **(%%) Open it and choose 522 522 523 523 * Product Model 524 524 * Uplink Interval ... ... @@ -526,34 +526,45 @@ 526 526 527 527 And the Life expectation in difference case will be shown on the right. 528 528 529 - (% style="text-align:center" %)659 + 530 530 [[image:image-20220907154700-22.jpeg]] 531 531 532 532 533 533 664 + 534 534 === 2.13.3 Battery Note === 535 535 667 + 536 536 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 537 537 670 + 671 + 538 538 === 2.13.4 Replace the battery === 539 539 674 + 540 540 The default battery pack of NSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 541 541 677 + 678 + 542 542 = 3. Access NB-IoT Module = 543 543 681 + 544 544 Users can directly access the AT command set of the NB-IoT module. 545 545 546 546 The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 547 547 548 - (% style="text-align:center" %)686 + 549 549 [[image:image-20220907154700-23.png]] 550 550 551 551 552 552 691 + 553 553 = 4. Using the AT Commands = 554 554 694 + 555 555 == 4.1 Access AT Commands == 556 556 697 + 557 557 See this link for detail: [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 558 558 559 559 AT+<CMD>? : Help on <CMD> ... ... @@ -564,8 +564,9 @@ 564 564 565 565 AT+<CMD>=? : Get the value 566 566 567 -**General Commands** 568 568 709 +(% style="color:#037691" %)**General Commands** 710 + 569 569 AT : Attention 570 570 571 571 AT? : Short Help ... ... @@ -609,16 +609,18 @@ 609 609 AT+ PHCAL : calibrate PH value 610 610 611 611 612 -**COAP Management** 754 +(% style="color:#037691" %)**COAP Management** 613 613 614 614 AT+URI : Resource parameters 615 615 616 -**UDP Management** 617 617 759 +(% style="color:#037691" %)**UDP Management** 760 + 618 618 AT+CFM : Upload confirmation mode (only valid for UDP) 619 619 620 -**MQTT Management** 621 621 764 +(% style="color:#037691" %)**MQTT Management** 765 + 622 622 AT+CLIENT : Get or Set MQTT client 623 623 624 624 AT+UNAME : Get or Set MQTT Username ... ... @@ -629,42 +629,63 @@ 629 629 630 630 AT+SUBTOPIC : Get or Set MQTT subscription topic 631 631 632 -**Information** 633 633 777 +(% style="color:#037691" %)**Information** 778 + 634 634 AT+FDR : Factory Data Reset 635 635 636 636 AT+PWORD : Serial Access Password 637 637 783 + 784 + 638 638 = 5. FAQ = 639 639 787 + 640 640 == 5.1 How to Upgrade Firmware == 641 641 790 + 642 642 User can upgrade the firmware for 1) bug fix, 2) new feature release. 643 643 644 644 Please see this link for how to upgrade: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]] 645 645 646 -**Notice, **NSPH01**and**NSPH01**share the same mother board. They use the same connection and method to update.**795 +(% style="color:red" %)**Notice, NSPH01 and LSPH01 share the same mother board. They use the same connection and method to update.** 647 647 797 + 798 + 648 648 == 5.2 Can I calibrate NSPH01 to different soil types? == 649 649 801 + 650 650 NSPH01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]]. 651 651 804 + 805 + 652 652 = 6. Trouble Shooting = 653 653 808 + 654 654 == 6.1 Connection problem when uploading firmware == 655 655 811 + 656 656 **Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]] 657 657 814 + 815 + 658 658 == 6.2 AT Command input doesn't work == 659 659 660 -In the case if user can see the console output but can't type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn't send **ENTER** while press the send key, user need to add ENTER in their string. 661 661 819 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string. 820 + 821 + 822 + 662 662 = 7. Order Info = 663 663 825 + 664 664 Part Number**:** NSPH01 665 665 828 + 829 + 666 666 = 8. Packing Info = 667 667 832 + 668 668 **Package Includes**: 669 669 670 670 * NSPH01 NB-IoT pH Sensor x 1 ... ... @@ -672,11 +672,16 @@ 672 672 673 673 **Dimension and weight**: 674 674 675 -* Size: 195 x 125 x 55 mm 676 -* Weight: 420g 840 +* Device Size: cm 841 +* Device Weight: g 842 +* Package Size / pcs : cm 843 +* Weight / pcs : g 677 677 845 + 846 + 678 678 = 9. Support = 679 679 849 + 680 680 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 681 681 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 682 682
- image-20220912144017-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +149.6 KB - Content
- image-20220923101327-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.1 KB - Content
- image-20221009000933-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +282.9 KB - Content