Changes for page NSPH01-NB-IoT Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/03/30 17:53
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -222,7 +222,7 @@ 222 222 223 223 **NOTE:** 224 224 225 -**~1. By default, the device will send an uplink message every 2hour.**225 +**~1. By default, the device will send an uplink message every 1 hour.** 226 226 227 227 **2.3 Uplink Payload** 228 228 ... ... @@ -231,7 +231,7 @@ 231 231 Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded. 232 232 233 233 (% style="width:934px" %) 234 -|(% style="width:93px" %)**Size(bytes)**|(% style="width:82px" %)**8**|(% style="width:43px" %)**2**|(% style="width:41px" %)**2**|(% style="width:126px" %)**1**|(% style="width:54px" %)**1**|(% style="width:84px" %)1|(% style="width:75px" %)2|(% style="width:133px" %)2|(% style="width:70px" %)2|(% style="width:127px" %)4 234 +|(% style="width:93px" %)**Size(bytes)**|(% style="width:82px" %)**8**|(% style="width:43px" %)**2**|(% style="width:41px" %)**2**|(% style="width:126px" %)**1**|(% style="width:54px" %)**1**|(% style="width:84px" %)1|(% style="width:75px" %)2|(% style="width:133px" %)2|(% style="width:70px" %)2|(% style="width:127px" %)4 235 235 |(% style="width:93px" %)**Value**|(% style="width:82px" %)Device ID|(% style="width:43px" %)Ver|(% style="width:41px" %)BAT|(% style="width:126px" %)Signal Strength|(% style="width:54px" %)MOD|(% style="width:84px" %)Interrupt|(% style="width:75px" %)Soil PH|(% style="width:133px" %)Soil Temperature|(% style="width:70px" %)Soil PH|(% style="width:127px" %)Time stamp ..... 236 236 237 237 If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NSPH01 uplink data. ... ... @@ -356,8 +356,7 @@ 356 356 357 357 By default, NSE01 prints the downlink payload to console port. 358 358 359 -(% style="text-align:center" %) 360 -[[image:image-20220907154636-17.png]] 359 +[[image:image-20220907154636-17.png||style="float:left"]] 361 361 362 362 363 363 ... ... @@ -364,7 +364,6 @@ 364 364 365 365 366 366 367 - 368 368 **Examples:** 369 369 370 370 * **Set TDC** ... ... @@ -427,6 +427,7 @@ 427 427 1. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 428 428 1. The probe is IP68 can be put in water. 429 429 428 + 430 430 **2.8 PH and Temperature alarm function** 431 431 432 432 ➢ AT Command: ... ... @@ -673,3 +673,4 @@ 673 673 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 674 674 675 675 675 +