Changes for page NSPH01-NB-IoT Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/03/30 17:53
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. David1 +XWiki.Xiaoling - Content
-
... ... @@ -1,17 +1,779 @@ 1 1 (% style="text-align:center" %) 2 -[[image:)YK]Y_LZJIO]J2~~VA}OQJM2.png]] 2 +[[image:)YK]Y_LZJIO]J2~~VA}OQJM2.png||height="442" width="410"]] 3 3 4 - =**1.Introduction**=4 +**Table of Contents:** 5 5 6 - == **1.1 Whatis NSPH01 Soil pH Sensor** ==6 +{{toc/}} 7 7 8 -The Dragino NSPH01 is a **NB-IOT soil ph sensor** for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 9 9 10 -NSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** pH **with high accuracy and stable value. The NSPH01 probe can be buried into soil for long time use. 11 11 10 += 1. Introduction = 11 + 12 +== 1.1 What is NSPH01 Soil pH Sensor == 13 + 14 + 15 +((( 16 +The Dragino NSPH01 is a (% style="color:blue" %)**NB-IoT soil pH sensor**(%%) for IoT of Agriculture. It is designed to measure the soil pH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 17 +))) 18 + 19 +((( 20 +NSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:blue" %)pH (%%)**with high accuracy and stable value. The NSPH01 probe can be buried into soil for long time use. 21 +))) 22 + 23 +((( 12 12 NarrowBand-Internet of Things (NB-IoT) is a standards-based low power wide area (LPWA) technology developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity and spectrum efficiency, especially in deep coverage. 13 -\\NSPH01 supports different uplink methods include **TCP,MQTT,UDP and CoAP **for different application requirement. 14 -\\NSPH01 is powered by **8500mAh Li-SOCI2 battery**, It is designed for long term use up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method) 15 -\\To use NSPH01, user needs to check if there is NB-IoT coverage in local area and with the bands NSPH01 supports. If the local operate support it, user needs to get a **NB-IoT SIM card** from local operator and install NSPH01 to get NB-IoT network connection. 25 +))) 16 16 27 +((( 28 +NSPH01 supports different uplink methods include (% style="color:blue" %)**TCP,MQTT,UDP and CoAP **(%%)for different application requirement. 29 +))) 30 + 31 +((( 32 +NSPH01 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method) 33 +))) 34 + 35 +((( 36 +To use NSPH01, user needs to check if there is NB-IoT coverage in the installation area and with the bands NSPH01 supports. If the local operator supports it, user needs to get a (% style="color:blue" %)**NB-IoT SIM card** (%%)from local operator and install NSPH01 to get NB-IoT network connection. 37 +))) 38 + 39 + 40 +[[image:image-20220907153151-1.png]] 41 + 42 + 43 +[[image:M_K`YF9`CAYAE\@}3T]FHT$9.png]] 44 + 45 + 46 +== 1.2 Features == 47 + 48 + 49 +* NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD 50 +* Monitor soil pH with temperature compensation. 51 +* Monitor soil temperature 52 +* pH and Temperature alarm function 53 +* Monitor Battery Level 54 +* Support pH calibration by end user 55 +* Uplink on periodically 56 +* Downlink to change configure 57 +* IP66 Waterproof Enclosure 58 +* IP68 rate for the Sensor Probe 59 +* Ultra-Low Power consumption 60 +* AT Commands to change parameters 61 +* Micro SIM card slot 62 +* 8500mAh Battery for long term use 63 + 64 + 65 + 66 +== 1.3 Specification == 67 + 68 + 69 +(% style="color:#037691" %)**Common DC Characteristics:** 70 + 71 +* Supply Voltage: 2.1v ~~ 3.6v 72 +* Operating Temperature: -40 ~~ 85°C 73 + 74 +(% style="color:#037691" %)**NB-IoT Spec:** 75 + 76 +* B1 @H-FDD: 2100MHz 77 +* B3 @H-FDD: 1800MHz 78 +* B8 @H-FDD: 900MHz 79 +* B5 @H-FDD: 850MHz 80 +* B20 @H-FDD: 800MHz 81 +* B28 @H-FDD: 700MHz 82 + 83 + 84 + 85 +== 1.4 Probe Specification == 86 + 87 + 88 +(% style="color:#037691" %)**Soil pH:** 89 + 90 +* Range: 3 ~~ 10 pH 91 +* Resolution: 0.01 pH 92 +* Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen) 93 +* Temperature Compensation Range: 0 ~~ 50℃ 94 +* IP68 Protection 95 +* Length: 3.5 meters 96 + 97 +(% style="color:#037691" %)**Soil Temperature:** 98 + 99 +* Range -40℃~85℃ 100 +* Resolution: 0.1℃ 101 +* Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others) 102 +* IP68 Protection 103 +* Length: 3.5 meters 104 + 105 + 106 + 107 +== 1.5 Applications == 108 + 109 + 110 +* Smart Agriculture 111 + 112 + 113 + 114 +== 1.6 Pin mapping and power on == 115 + 116 + 117 +[[image:image-20220907153300-2.png]] 118 + 119 + 120 += 2. Use NSPH01 to communicate with IoT Server = 121 + 122 +== 2.1 How it works == 123 + 124 + 125 +The NSPH01 is equipped with a NB-IoT module, the pre-loaded firmware in NSPH01 will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined by NSPH01. 126 + 127 +The diagram below shows the working flow in default firmware of NSPH01: 128 + 129 + 130 +[[image:image-20220907153416-3.png]] 131 + 132 + 133 +== 2.2 Configure the NSPH01 == 134 + 135 +=== 2.2.1 Test Requirement === 136 + 137 + 138 +To use NSPH01 in the field, make sure meet below requirements: 139 + 140 +* Your local operator has already distributed a NB-IoT Network there. 141 +* The local NB-IoT network used the band that NSPH01 supports. 142 +* Your operator is able to distribute the data received in their NB-IoT network to your IoT server. 143 + 144 +Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. The NSPH01 will use** CoAP(120.24.4.116:5683) **or raw **UDP(120.24.4.116:5601)** or **MQTT(120.24.4.116:1883)**or **TCP(120.24.4.116:5600)**protocol to send data to the test server. 145 + 146 + 147 +[[image:image-20220907153445-4.png]] 148 + 149 + 150 +=== 2.2.2 Insert SIM card === 151 + 152 + 153 +User need to take out the NB-IoT module and insert the SIM card like below. ((% style="color:red" %) Pay attention to the direction(%%)) 154 + 155 + 156 +[[image:image-20220907153505-5.png]] 157 + 158 + 159 +=== 2.2.3 Connect USB – TTL to NSPH01 to configure it === 160 + 161 + 162 +User need to configure NSPH01 via serial port to set the (% style="color:blue" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NSPH01 support AT Commands, user can use a USB to TTL adapter to connect to NSPH01 and use AT Commands to configure it, as below. 163 + 164 + 165 +(% style="color:blue" %)**Connection:** 166 + 167 +**~ (% style="background-color:yellow" %) USB TTL GND <~-~-~-~-> GND(%%)** 168 + 169 +**~ (% style="background-color:yellow" %) USB TTL TXD <~-~-~-~-> UART_RXD(%%)** 170 + 171 +**~ (% style="background-color:yellow" %) USB TTL RXD <~-~-~-~-> UART_TXD(%%)** 172 + 173 + 174 +In the PC, use below serial tool settings: 175 + 176 +* Baud: (% style="color:green" %)**9600** 177 +* Data bits:** (% style="color:green" %)8(%%)** 178 +* Stop bits: (% style="color:green" %)**1** 179 +* Parity: (% style="color:green" %)**None** 180 +* Flow Control: (% style="color:green" %)**None** 181 + 182 +Make sure the switch is in FLASH position, then power on device by connecting the jumper on NSPH01. NSPH01 will output system info once power on as below, we can enter the (% style="color:green" %)**password: 12345678**(%%) to access AT Command input. 183 + 184 + 185 +[[image:image-20220912144017-1.png]] 186 + 187 + 188 +(% style="color:red" %)**Note: the valid AT Commands can be found at:**(%%)** **[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 189 + 190 + 191 +=== 2.2.4 Use CoAP protocol to uplink data === 192 + 193 + 194 +(% style="color:red" %)**Note: if you don't have CoAP server, you can refer this link to set up one:**(%%)** **[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]] 195 + 196 + 197 +(% style="color:blue" %)**Use below commands:** 198 + 199 +* (% style="color:#037691" %)**AT+PRO=1** (%%) ~/~/ Set to use CoAP protocol to uplink 200 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5683 ** (%%) ~/~/ to set CoAP server address and port 201 +* (% style="color:#037691" %)**AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** (%%) ~/~/ Set COAP resource path 202 + 203 +For parameter description, please refer to AT command set 204 + 205 + 206 +[[image:image-20220907153551-7.png||height="502" width="740"]] 207 + 208 + 209 +After configure the server address and (% style="color:green" %)**reset the device (via AT+ATZ )**(%%), NSPH01 will start to uplink sensor values to CoAP server. 210 + 211 + 212 +[[image:image-20220907153612-8.png||height="529" width="729"]] 213 + 214 + 215 +=== 2.2.5 Use UDP protocol to uplink data(Default protocol) === 216 + 217 + 218 +This feature is supported since firmware version v1.0.1 219 + 220 +* (% style="color:blue" %)**AT+PRO=2 ** (%%) ~/~/ Set to use UDP protocol to uplink 221 +* (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5601 ** (%%) ~/~/ to set UDP server address and port 222 +* (% style="color:blue" %)**AT+CFM=1 ** (%%) ~/~/ If the server does not respond, this command is unnecessar 223 + 224 +[[image:image-20220907153643-9.png||height="401" width="734"]] 225 + 226 + 227 +[[image:image-20220907153703-10.png||height="309" width="738"]] 228 + 229 + 230 +=== 2.2.6 Use MQTT protocol to uplink data === 231 + 232 + 233 +This feature is supported since firmware version v110 234 + 235 +* (% style="color:blue" %)**AT+PRO=3 ** (%%) ~/~/ Set to use MQTT protocol to uplink 236 +* (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,1883 ** (%%) ~/~/ Set MQTT server address and port 237 +* (% style="color:blue" %)**AT+CLIENT=CLIENT ** (%%) ~/~/ Set up the CLIENT of MQTT 238 +* (% style="color:blue" %)**AT+UNAME=UNAME **(%%)~/~/ Set the username of MQTT 239 +* (% style="color:blue" %)**AT+PWD=PWD **(%%)~/~/ Set the password of MQTT 240 +* (% style="color:blue" %)**AT+PUBTOPIC=NSE01_PUB **(%%)~/~/ Set the sending topic of MQTT 241 +* (% style="color:blue" %)**AT+SUBTOPIC=NSE01_SUB ** (%%) ~/~/ Set the subscription topic of MQTT 242 + 243 +[[image:image-20220907153739-11.png||height="491" width="764"]] 244 + 245 + 246 +[[image:image-20220907153751-12.png||height="555" width="769"]] 247 + 248 + 249 +MQTT protocol has a much higher power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval. 250 + 251 + 252 +=== 2.2.7 Use TCP protocol to uplink data === 253 + 254 + 255 +This feature is supported since firmware version v110 256 + 257 +* (% style="color:blue" %)**AT+PRO=4 ** (%%) ~/~/ Set to use TCP protocol to uplink 258 +* (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5600 ** (%%) ~/~/ to set TCP server address and port 259 + 260 +[[image:image-20220907153818-13.png||height="486" width="668"]] 261 + 262 + 263 +[[image:image-20220907153827-14.png||height="236" width="684"]] 264 + 265 + 266 +=== 2.2.8 Change Update Interval === 267 + 268 + 269 +Users can use the below command to change the **uplink interval**. 270 + 271 +* (% style="color:blue" %)**AT+TDC=7200 ** (%%) ~/~/ Set Update Interval to 7200s (2 hour) 272 + 273 +(% style="color:red" %)**NOTE: By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).** 274 + 275 + 276 +== 2.3 Uplink Payload == 277 + 278 + 279 +In this mode, uplink payload includes 87 bytes in total by default. 280 + 281 +Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded. 282 + 283 +(% border="1.5" style="background-color:#ffffcc; color:green; width:520px" %) 284 +|=(% scope="row" style="width: 50px;" %)**Size(bytes)**|(% style="width:40px" %)**8**|(% style="width:20px" %)**2**|(% style="width:25px" %)**2**|(% style="width:60px" %)**1**|(% style="width:20px" %)**1**|(% style="width:40px" %)**1**|(% style="width:40px" %)**2**|(% style="width:50px" %)**2**|(% style="width:50px" %)**4**|(% style="width:50px" %)**2**|(% style="width:35px" %)**2**|(% style="width:40px" %)**4** 285 +|=(% style="width: 96px;" %)**Value**|(% style="width:83px" %)Device ID|(% style="width:44px" %)Ver|(% style="width:42px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:57px" %)MOD|(% style="width:80px" %)Interrupt|(% style="width:69px" %)Soil PH|(% style="width:134px" %)Soil Temperature|(% style="width:98px" %)Time stamp|(% style="width:134px" %)Soil Temperature|(% style="width:68px" %)Soil PH|(% style="width:125px" %)Time stamp ..... 286 + 287 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NSPH01 uplink data. 288 + 289 +[[image:image-20220907153902-15.png||height="581" width="804"]] 290 + 291 + 292 +((( 293 +The payload is ASCII string, representative same HEX: 294 +))) 295 + 296 +((( 17 17 298 +))) 299 + 300 +((( 301 +**0x (% style="color:red" %)__f868411056754138__ (% style="color:blue" %)__0064 __ (% style="color:green" %)__0c78__ (% style="color:#00b0f0" %)__17__ (% style="color:#7030a0" %)__01__ (% style="color:#d60093" %)__00__ (% style="color:#a14d07" %)__0225 __ (% style="color:#0020b0" %) __010b__ (% style="color:#420042" %)__6315537b__ (% style="color:#663300" %)//__010b0226631550fb__ __010e022663154d77 01110225631549f1 011502246315466b 01190223631542e5 011d022163153f62 011e022163153bde 011e022163153859__//(%%)** 302 +))) 303 + 304 +((( 305 + 306 + 307 +**where:** 308 +))) 309 + 310 +* (% style="color:#037691" %)**Device ID:**(%%)** **0xf868411056754138 = f868411056754138 311 + 312 +* (% style="color:#037691" %)**Version:** (%%) 0x0064=100=1.0.0 313 + 314 +* (% style="color:#037691" %)**BAT:** (%%) 0x0c78 = 3192 mV = 3.192V 315 + 316 +* (% style="color:#037691" %)**Singal:** (%%)0x17 = 23 317 + 318 +* (% style="color:#037691" %)**Mod:** (%%) 0x01 = 1 319 + 320 +* (% style="color:#037691" %)**Interrupt:**(%%) 0x00= 0 321 + 322 +* (% style="color:#037691" %)**Soil PH:** (%%) 0x0225= 549 = 5.49 323 + 324 +* (% style="color:#037691" %)**Soil Temperature:**(%%) 0x010b =267=26.7 °C 325 + 326 +* (% style="color:#037691" %)**Time stamp :** (%%) 0x6315537b =1662342011 ([[Unix Epoch Time>>url:http://www.epochconverter.com/]]) 327 + 328 +* (% style="color:#037691" %)**Soil Temperature,Soil PH,Time stamp : **(%%) 010b0226631550fb 329 + 330 +* (% style="color:#037691" %)**8 sets of recorded data:**(%%) Temperature,Soil PH,Time stamp : 010e022663154d77,....... 331 + 332 + 333 + 334 +== 2.4 Payload Explanation and Sensor Interface == 335 + 336 +=== 2.4.1 Device ID === 337 + 338 + 339 +By default, the Device ID equal to the last 15 bits of IMEI. 340 + 341 +User can use (% style="color:blue" %)**AT+DEUI** (%%)to set Device ID 342 + 343 + 344 +**Example:** 345 + 346 +AT+DEUI=868411056754138 347 + 348 +The Device ID is stored in a none-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID. 349 + 350 + 351 +=== 2.4.2 Version Info === 352 + 353 + 354 +Specify the software version: 0x64=100, means firmware version 1.00. 355 + 356 +For example: 0x00 64 : this device is NSPH01 with firmware version 1.0.0. 357 + 358 + 359 +=== 2.4.3 Battery Info === 360 + 361 + 362 +Check the battery voltage for NSPH01. 363 + 364 +Ex1: 0x0B45 = 2885mV 365 + 366 +Ex2: 0x0B49 = 2889mV 367 + 368 + 369 +=== 2.4.4 Signal Strength === 370 + 371 + 372 +NB-IoT Network signal Strength. 373 + 374 +**Ex1: 0x1d = 29** 375 + 376 +**0** -113dBm or less 377 + 378 +**1** -111dBm 379 + 380 +**2...30** -109dBm... -53dBm 381 + 382 +**31** -51dBm or greater 383 + 384 +**99** Not known or not detectable 385 + 386 + 387 +=== 2.4.5 Soil PH === 388 + 389 + 390 +Get the PH content of the soil. The value range of the register is 300-1000(Decimal), divide this value by 100 to get the percentage of PH in the soil. 391 + 392 +For example, if the data you get from the register is (% style="color:blue" %)**__0x05 0xDC__**(%%), the PH content in the soil is 393 + 394 +(% style="color:blue" %)**0229(H) = 549(D) /100 = 5.49.** 395 + 396 + 397 +=== 2.4.6 Soil Temperature === 398 + 399 + 400 +Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is (% style="color:blue" %)**__0x09 0xEC__**(%%), the temperature content in the soil is 401 + 402 + 403 +**Example**: 404 + 405 +If payload is 0105H: ((0x0105 & 0x8000)>>15 === 0),temp = 0105(H)/10 = 26.1 °C 406 + 407 +If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/10 = -12.9 °C 408 + 409 + 410 +=== 2.4.7 Timestamp === 411 + 412 + 413 +Time stamp : 0x6315537b =1662342011 414 + 415 +Convert Unix timestamp to time 2022-9-5 9:40:11. 416 + 417 + 418 +=== 2.4.8 Digital Interrupt === 419 + 420 + 421 +Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NSPH01 will send a packet to the server. 422 + 423 +The command is: 424 + 425 +(% style="color:blue" %)**AT+INTMOD=3 ** (%%) ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.** 426 + 427 +The lower four bits of this data field shows if this packet is generated by interrupt or not. Click here for the hardware and software set up. 428 + 429 + 430 +**Example:** 431 + 432 +0x(00): Normal uplink packet. 433 + 434 +0x(01): Interrupt Uplink Packet. 435 + 436 + 437 +=== 2.4.9 +5V Output === 438 + 439 + 440 +NSPH01 will enable +5V output before all sampling and disable the +5v after all sampling. 441 + 442 +The 5V output time can be controlled by AT Command. 443 + 444 +(% style="color:blue" %)**AT+5VT=1000** 445 + 446 +Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.** ** 447 + 448 + 449 +== 2.5 Downlink Payload == 450 + 451 + 452 +By default, NSPH01 prints the downlink payload to console port. 453 + 454 +[[image:image-20220907154636-17.png]] 455 + 456 + 457 +(% style="color:blue" %)**Examples:** 458 + 459 +* (% style="color:#037691" %)** Set TDC** 460 + 461 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 462 + 463 +Payload: 01 00 00 1E TDC=30S 464 + 465 +Payload: 01 00 00 3C TDC=60S 466 + 467 +* (% style="color:#037691" %)** Reset** 468 + 469 +If payload = 0x04FF, it will reset the NSPH01 470 + 471 +* (% style="color:#037691" %)** INTMOD** 472 + 473 +Downlink Payload: 06000003, Set AT+INTMOD=3 474 + 475 + 476 +== 2.6 LED Indicator == 477 + 478 + 479 +The NSPH01 has an internal LED which is to show the status of different state. 480 + 481 +* When power on, NSPH01 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe) 482 +* Then the LED will be on for 1 second means device is boot normally. 483 +* After NSPH01 join NB-IoT network. The LED will be ON for 3 seconds. 484 +* For each uplink probe, LED will be on for 500ms. 485 + 486 + 487 + 488 +== 2.7 Installation and Maintain == 489 + 490 +=== 2.7.1 Before measurement === 491 + 492 + 493 +If the NSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 494 + 495 + 496 +=== 2.7.2 Measurement === 497 + 498 + 499 +(% style="color:#037691" %)**Measurement the soil surface:** 500 + 501 + 502 +[[image:image-20220907154700-18.png]] 503 + 504 +Choose the proper measuring position. Split the surface soil according to the measured deep. 505 + 506 +Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things. 507 + 508 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting. 509 + 510 +Put soil over the probe after insert. And start to measure. 511 + 512 + 513 +(% style="color:#037691" %)**Measurement inside soil:** 514 + 515 +Dig a hole with diameter > 20CM. 516 + 517 +Insert the probe inside, method like measure the surface. 518 + 519 + 520 +=== 2.7.3 Maintain Probe === 521 + 522 + 523 +1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 524 +1. After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 525 +1. Probe reference electrode is also no strong, need to avoid strong force or hitting. 526 +1. User should keep reference electrode wet while not use. 527 +1. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 528 +1. The probe is IP68 can be put in water. 529 + 530 + 531 + 532 +== 2.8 PH and Temperature alarm function == 533 + 534 + 535 +(% style="color:#037691" %)**➢ AT Command:** 536 + 537 +(% style="color:blue" %)**AT+ PHALARM=min,max** 538 + 539 +² When min=3, and max≠0, Alarm higher than max 540 + 541 +² When min≠0, and max=0, Alarm lower than min 542 + 543 +² When min≠0 and max≠0, Alarm higher than max or lower than min 544 + 545 + 546 +(% style="color:blue" %)**Example:** 547 + 548 +AT+ PHALARM =5,8 ~/~/ Alarm when PH lower than 5. 549 + 550 +AT+ TEMPALARM=min,max 551 + 552 +² When min=0, and max≠0, Alarm higher than max 553 + 554 +² When min≠0, and max=0, Alarm lower than min 555 + 556 +² When min≠0 and max≠0, Alarm higher than max or lower than min 557 + 558 + 559 +(% style="color:blue" %)**Example:** 560 + 561 +AT+ TEMPALARM=20,30 ~/~/ Alarm when temperature lower than 20. 562 + 563 + 564 +== 2.9 Set the number of data to be uploaded and the recording time == 565 + 566 + 567 +(% style="color:#037691" %)**➢ AT Command:** 568 + 569 +* (% style="color:blue" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 570 +* (% style="color:blue" %)**AT+NOUD=8** (%%) ~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 571 + 572 + The diagram below explains the relationship between TR, NOUD, and TDC more clearly**:** 573 + 574 +[[image:image-20221009000933-1.png||height="750" width="1043"]] 575 + 576 + 577 +== 2.10 Read or Clear cached data == 578 + 579 + 580 +(% style="color:#037691" %)**➢ AT Command:** 581 + 582 +* (% style="color:blue" %)**AT+CDP** (%%) ~/~/ Read cached data 583 +* (% style="color:blue" %)**AT+CDP=0** (%%) ~/~/ Clear cached data 584 + 585 +[[image:image-20220907154700-19.png]] 586 + 587 + 588 +== 2.11 Calibration == 589 + 590 + 591 +User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 592 + 593 +After stable, user can use below command to calibrate. 594 + 595 + 596 +[[image:image-20220907154700-20.png]] 597 + 598 + 599 +== 2.12 Firmware Change Log == 600 + 601 + 602 +Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/1tv07fro2pvjqj8/AAD-2wbfGfluTZfh38fQqdA_a?dl=0>>https://www.dropbox.com/sh/1tv07fro2pvjqj8/AAD-2wbfGfluTZfh38fQqdA_a?dl=0]] 603 + 604 +Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]] 605 + 606 + 607 +== 2.13 Battery & Power Consumption == 608 + 609 + 610 +NSPH01 uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 611 + 612 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 613 + 614 + 615 += 3. Access NB-IoT Module = 616 + 617 + 618 +Users can directly access the AT command set of the NB-IoT module. 619 + 620 +The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 621 + 622 + 623 +[[image:image-20220907154700-23.png]] 624 + 625 + 626 + 627 += 4. Using the AT Commands = 628 + 629 +== 4.1 Access AT Commands == 630 + 631 + 632 +See this link for detail: [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 633 + 634 +AT+<CMD>? : Help on <CMD> 635 + 636 +AT+<CMD> : Run <CMD> 637 + 638 +AT+<CMD>=<value> : Set the value 639 + 640 +AT+<CMD>=? : Get the value 641 + 642 + 643 +(% style="color:#037691" %)**General Commands** 644 + 645 +AT : Attention 646 + 647 +AT? : Short Help 648 + 649 +ATZ : MCU Reset 650 + 651 +AT+TDC : Application Data Transmission Interval 652 + 653 +AT+CFG : Print all configurations 654 + 655 +AT+CFGMOD : Working mode selection 656 + 657 +AT+INTMOD : Set the trigger interrupt mode 658 + 659 +AT+5VT : Set extend the time of 5V power 660 + 661 +AT+PRO : Choose agreement 662 + 663 +AT+RXDL : Extend the sending and receiving time 664 + 665 +AT+SERVADDR : Server Address 666 + 667 +AT+TR : Get or Set record time" 668 + 669 +AT+APN : Get or set the APN 670 + 671 +AT+FBAND : Get or Set whether to automatically modify the frequency band 672 + 673 +AT+DNSCFG : Get or Set DNS Server 674 + 675 +AT+GETSENSORVALUE : Returns the current sensor measurement 676 + 677 +AT+NOUD : Get or Set the number of data to be uploaded 678 + 679 +AT+CDP : Read or Clear cached data 680 + 681 +AT+TEMPALARM : Get or Set alarm of temp 682 + 683 +AT+PHALARM : Get or Set alarm of PH 684 + 685 +AT+ PHCAL : calibrate PH value 686 + 687 + 688 +(% style="color:#037691" %)**COAP Management** 689 + 690 +AT+URI : Resource parameters 691 + 692 + 693 +(% style="color:#037691" %)**UDP Management** 694 + 695 +AT+CFM : Upload confirmation mode (only valid for UDP) 696 + 697 + 698 +(% style="color:#037691" %)**MQTT Management** 699 + 700 +AT+CLIENT : Get or Set MQTT client 701 + 702 +AT+UNAME : Get or Set MQTT Username 703 + 704 +AT+PWD : Get or Set MQTT password 705 + 706 +AT+PUBTOPIC : Get or Set MQTT publish topic 707 + 708 +AT+SUBTOPIC : Get or Set MQTT subscription topic 709 + 710 + 711 +(% style="color:#037691" %)**Information** 712 + 713 +AT+FDR : Factory Data Reset 714 + 715 +AT+PWORD : Serial Access Password 716 + 717 + 718 += 5. FAQ = 719 + 720 +== 5.1 How to Upgrade Firmware == 721 + 722 + 723 +User can upgrade the firmware for 1) bug fix, 2) new feature release. 724 + 725 +Please see this link for how to upgrade: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]] 726 + 727 +(% style="color:red" %)**Notice, NSPH01 and LSPH01 share the same mother board. They use the same connection and method to update.** 728 + 729 + 730 +== 5.2 Can I calibrate NSPH01 to different soil types? == 731 + 732 + 733 +NSPH01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]]. 734 + 735 + 736 += 6. Trouble Shooting = 737 + 738 +== 6.1 Connection problem when uploading firmware == 739 + 740 + 741 +**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]] 742 + 743 + 744 +== 6.2 AT Command input doesn't work == 745 + 746 + 747 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string. 748 + 749 + 750 += 7. Order Info = 751 + 752 + 753 +Part Number**:** NSPH01 754 + 755 + 756 += 8. Packing Info = 757 + 758 + 759 +**Package Includes**: 760 + 761 +* NSPH01 NB-IoT pH Sensor x 1 762 +* External antenna x 1 763 + 764 +**Dimension and weight**: 765 + 766 +* Device Size: cm 767 +* Device Weight: g 768 +* Package Size / pcs : cm 769 +* Weight / pcs : g 770 + 771 + 772 + 773 += 9. Support = 774 + 775 + 776 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 777 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 778 + 779 +
- image-20220912144017-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +149.6 KB - Content
- image-20220923101327-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.1 KB - Content
- image-20221009000933-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +282.9 KB - Content